header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 59 - 59
11 Apr 2023
Chitto M Chen B Kunisch F Wychowaniec J Onsea J Post V Richards G Zeiter S Wagemans J Trampuz A D'Este M Moreno M Lavigne R Moriarty F
Full Access

Fracture related infection remains a major challenge in musculoskeletal trauma surgery. Despite best practice, treatment strategies suffer from high failure rates due to antibiotic resistance and tolerance. Bacteriophages represent a promising alternative as they retain activity against such bacteria. However, optimal phage administration protocols remain unknown, although injectable hydrogels, loaded with phage and conventional antibiotics, may support conventional therapy.

In this study we tested the activity of meropenem, and two newly isolated bacteriophages (ϕ9 and ϕ3) embedded within alginate-chitosan microbeads and a hydrogel. Antibiotic and phage stability and activity were monitored in vitro, over a period of 10 days. In vivo, the same material was tested in treatment of a 5-day old Pseudomonas aeruginosa infection of a tibial plate osteotomy in mice. Treatment involved debridement and 5 days of systemic antibiotic therapy plus: i- saline, ii-phages in saline, iii-phages and antibiotics loaded into a hydrogel (n=7 mice/group). To assess the efficacy of the treatments, the infection load was monitored during revision surgery with debridement of the infected tissue after 5,10 and 13 days (euthanasia) by CFU and PFU quantification.

In vitro testing confirmed that the stability of meropenem and activity of ϕ9 and ϕ3, was not affected within the alginate beads or hydrogel over 10 days. The in vivo study showed that all mice receiving phages and antibiotics loaded into a hydrogel survived the infection with a reduction of the bacterial load in the soft tissue. Active phages could be recovered from the infected site at euthanasia (104 PFU/g).

The hydrogel loaded with bacteriophages and meropenem showed a positive result in locally reducing the infection load indicating a synergistic effect of the selected antimicrobials. Overall, our new strategy shows encouraging results for improving the treatment of antibiotic-resistant biofilm infections that are related to medical implants.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 283 - 283
1 Jul 2014
Post V Wahl P Uckay I Zimmerli W Corvec S Loiez C Ochsner P Moriarty F
Full Access

Summary

Staphylococcus aureus isolates from Fracture fixation device related infections contained fewer isolates that form a strong biofilm in comparison with isolates from Prosthetic joint infections. Both orthopaedic implant related infection groups possessed fnbB and sdrE more frequently than the non-implant related infection groups.

Introduction

One of the most common pathogen causing musculoskeletal infections is Staphylococcus aureus. The aim was to characterise S. aureus isolated from these infections and to look for differences between the isolates from orthopaedic implant related infections (OIRI) and those in non-implant related infections (NIRI). The OIRI are further differentiated in those associated with fracture fixation (FFI) devices and those found in prosthetic joint infections (PJI).