The objective of this study was to investigate how a new customizable light-curable osteosynthesis method (AdFix) compared to traditional metal hardware when loaded in torsion in an ovine phalanx model. Twenty-one ovine proximal phalanges were given a 3mm transverse osteotomy and four 1.5mm cortex screws were inserted bicortically on either side of the gap. The light-curable polymer composite was then applied using the method developed by Hutchinson [1] to create osteosyntheses in two groups, having either a narrow (6mm, N=9) or a wide (10mm, N=9) fixation patch. A final group (N=3) was fixated with conventional metal plates. The constructs were loaded in torsion at a rate of 6°/second until failure or 45° of rotation was reached. Torque and angular displacement were measured, torsional stiffness was calculated as the slope of the Torque-Displacement curve, and maximum torque was queried for each specimen. The torsional stiffnesses of the narrow, wide, and metal plate constructs were 39.1 ± 6.2, 54.4 ± 6.3, and 16.2 ± 3.0 Nmm/° respectively. All groups were statistically different from each other (p<0.001). The maximum torques of the narrow, wide, and metal plate constructs were 424 ± 72, 600 ± 120, and 579 ± 20 Nmm respectively. The narrow constructs were statistically different from the other two (p<0.05), while the wide and metal constructs were not statistically different from each other (p=0.76). This work demonstrated that the torsional performance of the novel solution is comparable to metal fixators. As a measure of the functional range, the torsional stiffness in the AdhFix exceeded that of the metal plate. Furthermore, the wide patches were able to sustain a similar maximum toque as the metal plates. These results suggest AdhFix to be a viable, customizable alternative to metal implants for fracture fixation in the hand.
Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS). Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)).Aims
Methods
In certain clinical situations, complex local anatomy and limitations of surgical exposure can make adequate and bone tumor ablation, resection and reconstruction very challenging. We wished to review our clinical experience and accuracy achieved with entirely virtually planned single stage tumor ablation/resection and reconstructions. We report 6 cases of bone tumors in which tumor removal (by radio-frequency (RF) ablation and/or resection) and subsequent reconstruction were based entirely on pre-operative virtual analysis and planning. All interventions were accomplished with specifically designed and pre-operatively manufactured 3D-printed drill & resection guides. Immediate subsequent defect reconstruction was either performed with a precisely matching allograft (n=1) or composite metal implant (n=5) consisting of a defect specific titanium scaffold and multiple integrated fixation features to provide optimal immediate stability as well as subsequent opportunity for osseointegration. We reviewed the sequence of all procedural steps as well as the accuracy of each saw blade or drill trajectory by direct intra-operative measurement, post-operative margin status and virtual comparison of pre- and post-operative CT scans.Background
Methods
To demonstrate the role of an antibiotic containing bone substitute, native bone active proteins and muscle transforming into bone.
Recurrent osteomyelitis was eradicated and filled with a gentamycin eluting bone substitute (Cerament™l G) consisting of sulphate and apatite phases and covered by a muscle flap. C2C12 muscle cells were seeded on the bone substitute in-vitro and their phenotype was studied. Another muscle cell line L6 was seeded with osteoblast conditioned medium containing bone active proteins and specific markers were studied for bone differentiation.
A chronic, longstanding, fistulating osteomyelitis was operated with radical eradication and filling of the cavity with gentamycin eluting bone substitute. At one year, the patient had no leg pain and a healed wound. Significant bone was also seen in the overlaying muscle, at one month post-op disappearing after 6-months. Local delivery of gentamycin had a protective effect on bone formation. C2C12 cells seeded on the gentamycin eluting bone substitute depicted no difference in proliferation when compared to plain bone substitute and expressed 4 folds higher Alkaline phosphatase (ALP) compared to controls. C2C12 cells expressed proteins and genes coding for collagen type 1 (Col 1), osteocalcin (OCN), osteopontin (OPN) and bonesialoprotein (BSP). L6 cells cultured with osteoblast conditioned medium remained uninucleated and expressed osteoblastic proteins like Col 1, OCN, OPN and BSP.
Bone substitute with gentamycin leads to differentiation of mesenchymal cells into bone in-vitro. Native bone active proteins from an osteoblast culture can induce differentiation of muscle cells in-vitro. Clinical observations with rapid bone formed in the bone substitute and in some cases in the muscle are a consequence of both leakage of bone active proteins and also from osteoprogenitor cells coming from the overlaying muscle interacting with the osteoinductive bone substitute.
To report our experience with the use of local antibiotic co-delivery with a synthetic bone graft substitute during a second stage re-implantation of an infected proximal humeral replacement. A 72 year old man was admitted to our department with a pathological fracture through an osteolytic lesion in the left proximal humerus, due to IgG Myelomatosis. He was initially treated with a cemented proximal humerus replacement hemiarthroplasty. Peri-prosthetic joint infection (PJI) with significant joint distention was evident three weeks post operatively. Revision surgery confirmed presence of a large collection of pus and revealed disruption of the soft tissue reattachment tube, as well as complete retraction of rotator cuff and residual capsule. All modular components were removed and an antibiotic-laden cement spacer (1.8g of Clindamycin and Gentamycin, respectively) was implanted onto the well-fixed cemented humeral stem. Initial treatment with i.v. Amoxicillin/Clavulanic acid was changed to Rifampicin and Fusidic Acid during a further 8 weeks after cultures revealed growth of S. epidermidis. During second stage revision, a hybrid inverse prosthesis with silver coating was implanted, with a total of 20 ml Cerament ™G (injected into the glenoid cavity prior to insertion of the base plate and around the humeral implant-bone interface) and again stabilized with a Trevira tube. Unfortunately, this prosthesis remained unstable, ultimately requiring re-revision to a completely new constrained reverse prosthesis with a custom glenoid shell and silver-coated proximal humeral component. 18 months postoperatively, the patient's shoulder remains pain free and stable, without signs of persistent or reinfection since the initial second stage revision. The function however, unfortunately remains poor. This case report illustrates the application of an antibiotic-eluting bone graft substitute in a specific clinical situation, where co-delivery of an antibiotic together with a bone remodeling agent may be beneficial to simultaneously address PJI as well as poor residual bone quality.
To document early in-vivo concentrations of gentamicin in plasma and drain fluid after bone defect reconstruction using a gentamicin-eluting bone graft substitute. Introduction Reconstruction of bone defects after surgical bone tumor resection is associated with an increased risk of infection and some surgeons therefore prefer extended antibiotic prophylaxis in these patients. A gentamicin-eluting bone graft substitute consisting of sulphate and apatite has been shown to be effective for treatment of osteomyelitis(1) and may be a valuable addition to the therapeutic and/or prophylactic antibiotic regime for this and many other indications. We performed a prospective pilot study from December 2014 to February 2015 in 7 patients (M/F: 4/3, mean age 51 (37–79) years) who underwent bone defect reconstruction with a gentamicin-eluting bone graft substitute (CERAMENT™|G – BONESUPPORT AB) containing 175 mg gentamicin per 10 mL. Indications for surgery were metastatic bone disease (n=3, proximal humerus), giant cell tumor (n=2, distal femur), aseptic prosthetic loosening (n=1, knee) and chondroid tumor (n=1, distal femur). Additional endoprosthetic reconstruction with a tumor prosthesis was performed in 3 patients (2 proximal humerus and 1 distal femur). Drain fluid and plasma was collected immediately postoperatively and each postoperative day until the drain was removed. In 2 cases we were unable to collect drain fluid directly postoperatively due to minimal fluid production. Gentamicin concentrations were analyzed using an antibody technique (Indiko™ – Thermo Scientific). A mean of 14 (10–20) mL gentamicin-eluting bone graft substitute was used, either alone or in combination with cancellous allograft and/or a bone graft substitute not containing gentamicin (CERAMENT™|BVF – BONESUPPORT AB). Mean drain fluid concentrations of gentamicin were 1200 (723–2100) mg/L immediately postoperative (0–2 hours), 1054 (300–1999) mg/L on day 1 (17–23 hours) and 509 (38–1000) mg/L on day 2 (39–45 hours). Mean plasma concentrations of gentamicin were 1.26 (1.08–1.42) mg/L immediately postoperative, 0.95 (0.25–2.06) mg/L on day 1 and 0.56 (0.20–0.88) mg/L on day 2. Discussion. As gentamicin induces a concentration-dependent bacterial killing effect, the obviously high local peak concentrations of gentamicin found in this study would be expected to deliver a substantial prophylactic effect after long operations with an increased risk of intraoperative bacterial contamination. Local implantation of a gentamicin-eluting bone graft substitute for bone defect reconstruction results in high concentrations of gentamicin in the drain fluid in the first postoperative days and low plasma concentrations.
Endoprosthetic reconstruction for pathologic acetabular fractures is associated with a high risk of periprosthetic joint infection. In this setting, bone defect reconstruction utilising co-delivery of a synthetic bone substitute with an antibiotic, is an attractive treatment option from both, therapeutic and prophylactic perspective. We wished to address some concerns that remain regarding the possible presence of potentially wear inducing particles in the periprosthetic joint space subsequent to this procedure. We analysed a drain fluid sample from an endoprosthetic reconstruction of a pathologic acetabular fracture with implantation of a gentamicin eluting, biphasic bone graft substitute, consisting of 40% hydroxyapatite (HA) and 60% calcium sulphate (CERAMENT G), into the residual peri-acetabular bone defect. This sample was divided into two 1.5ml subsamples, to one of which 100mg HA particles were added as control before burning off all organic substance at very high temperature. These heat treated samples were then examined with scanning electron microscopy (SEM) and energy dispersive x-ray analysis (EDAX) and compared to a reference sample consisting of HA particles only. On SEM, hydroxyapatite particles were readily recognisable in the control and reference samples, whereas only very few particles over 2μm were apparent in the ”pure” drain sample. EDAX revealed that very large amounts of salts were present in both drainage samples. The pure drainage sample however, contained markedly lower amounts of calcium and phosphate compared to reference and control samples. No HA particles as such, were seen in the pure sample, however their presence cannot be excluded with absolute certainty, as some particles might have been hidden within the large salt conglomerates. We could not find clear evidence that the drain fluid really contained HA particles. More thorough investigations are needed and future analyses with prior removal of the high salt content would likely yield more conclusive results.
Randomized, controlled trials (RCTs) are generally accepted as the “gold standard” for the provision of the most unbiased measures of the efficacy of interventions but are often criticized for the lack of external validity. We assessed the external validity of a RCT examining the efficacy of local infiltration analgesia (LIA) compared with continuous epidural infusion after total knee arthroplasty (TKA) During a one-year period, all patients consecutively admitted for elective, unilateral, primary TKA were identified as potential participants. All underwent eligibility screening to determine who were eligible for participation in a randomized controlled trial. We investigated the distribution of preoperative characteristics and postoperative variables among excluded patients, non-consenters, and enrolled and randomized participants.Background
Methods