The aims of this study were to determine the success of a reconstruction algorithm used in major acetabular bone loss, and to further define the indications for custom-made implants in major acetabular bone loss. We reviewed a consecutive series of Paprosky type III acetabular defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical acetabular component. IIIB defects were planned to receive either a hemispherical acetabular component plus augments, a cup-cage reconstruction, or a custom-made implant. We used national digital health records and registry reports to identify any reoperation or re-revision procedure and Oxford Hip Score (OHS) for patient-reported outcomes. Implant survival was determined via Kaplan-Meier analysis.Aims
Methods
Contemporary acetabular reconstruction in major acetabular bone loss often involves the use of porous metal augments, a cup-cage construct or custom implant. The aims of this study were: To determine the reproducibility of a reconstruction algorithm in major acetabular bone loss. To determine the subsequent success of reconstruction performed in terms of re-operation, all-cause revision and Oxford Hip Score (OHS) and to further define the indications for custom implants in major acetabular bone loss. Consecutive series of Paprosky Type III defects treated according to a reconstruction algorithm. IIIA defects were planned to use a superior augment and hemispherical cup. IIIB defects were planned to receive either augment and cup, cup-cage or custom implant. 105 procedures in cohort 100 patients (5 bilateral) with mean age 73 years (42–94). IIIA defects (50 cases) − 72.0% (95%CI 57.6–82.1) required a porous metal augment the remainder treated with a hemispherical cup alone. IIIB defects (55 cases) 71.7% (95%CI 57.6–82.1) required either augments or cup-cage. 20 patients required a hemispherical cup alone and 6 patients received a custom-made implant. Mean follow up of 7.6 years. 6 re-revisions were required (4 PJI, 2 peri-prosthetic fractures & 1 recurrent instability) with overall survivorship of 94.3% (95% CI 97.4–88.1) for all cause revision. Single event dislocations occurred in 3 other patients so overall dislocation rate 3.8%. Mean pre-op OHS 13.8 and mean follow-up OHS 29.8. Custom implants were used in: Mega-defects where AP diameter >80mm, complex discontinuity and massive bone loss in a small pelvis (i.e., unable to perform cup-cage) A reconstruction algorithm can >70% successfully predict revision construct which thereafter is durable with a low risk of re-operation. Jumbo cup utilized <1/3 of cases when morphology allowed. The use of custom implants has been well defined in this series and accounts for <5% of cases.
Hypochlorous acid (HOCl) is a potent anti-bacterial agent which could reduce periprosthetic joint infection. Early infection complications in joint replacements are often considered to be due to local contamination at the time of surgery and result in a significant socioeconomic cost. Current theatre cleaning procedures produce “clean” operating theatres which still contain bacteria (colony forming units, CFU). Reducing this bacterial load may reduce local contamination at the time of surgery. HOCl is produced naturally in the human neutrophil and has been implicated as the primary agent involved in bacterial killing during this process. In vitro research confirms its efficacy against essentially all clinically relevant bacteria. The recent advent of commercial production of HOCl, delivered as a fog, has resulted in extensive use in the food industry. Reported lack of corrosion and high anti-bacterial potency are seen as two key factors for the use of HOCl in the orthopaedic environment. Prior work by the authors comparing human cell toxicity of HOCl, chlorhexidine and iodine solutions shows favourable results. This study evaluates use of neutral HOCl applied as a dry room fog to decrease bacteria in the operating theatre environment. Using an animal operating theatre as the test site, bacterial swabs were taken from ten 100cm2 sample areas before standard cleaning with detergent, after standard cleaning, and again after 60 minutes exposure to HOCl fog. After standard cleaning, 6 of 10 sample sites recorded significant bacterial growth (>10 CFU/100cm2). After exposure to HOCl fog, growth in all 10 sites was below detection limits (<10 CFU/100cm2). This was repeated with specific exposure to We can conclude that HOCl is effective when used as a fogging agent to reduce bacterial loading within an operating theatre environment and as such has significant potential to reduce intraoperative contamination and periprosthetic infection.
To review the outcome of deep prosthetic infection in patients following hip hemiarthroplasty surgery. A retrospective case-note analysis was performed of deep infection coded hip hemiarthroplasty patients between 2004–2009. Patients were selected when there was proven microbiology from deep wound swabs or tissue specimens.Aim
Method
Surgical options in the treatment of acute acromio-clavicular joint (Rockwood Type III and IV) dislocations are many and controversial. We evaluated our technique using TIGHTROPE connecting the base of the coracoid to the proximal fragment of the clavicle. Between March 2006 and December 2006, ten young and active adult patients with acute ACJ dislocations were treated with arthroscopically assisted ARTHREX TIGHTROPE fixation. The dislocation was reduced with traction and manual reduction with the patient in beach-chair position. The base of the coracoid was identified and isolated using a radiofrequency ablator placed through the anterior portal while visualizing through the lateral portal. An ACL guide was placed percutaneously supero-medial to the coracoid over the distal with the inferior end of the ACL guide placed through a posterior portal, approximated against the prepared base of the coracoid. The Arthrex Tightrope braided fibre-wire was introduced through the pre-drilled distal clavicle passed to the base of the coracoid and manually tensioned to achieve stable reduction. Standard rehabilitation protocol was utilised as for internal fixation of distal clavicular fractures. Patients were evaluated clinically using Constant Score, which ranged from 75 to 83 and radiologically at 6 weeks and 3 months. We present the functional results and the technical difficulties faced highlighting on the probable reasons for failure of fixation in two of our early patients who had revision fixations. We also describe the additional intra-operative techniques used in the last few patients to prevent such complications and achieve a secure reduction. We conclude that Arthroscopic Reconstruction of dislocated Acromio-Clavicular joint using TIGHTROPE may require additional repair of the ligaments in carefully selected patients to prevent failure of fixation.
A retrospective study was made of the results of surgical treatment of subluxation or dislocation of the hip in patients who had suffered from poliomyelitis. Good results were achieved in 46% and satisfactory results in 24%. The key factors for success are muscle balance, the femoral neck-shaft and anteversion angles, and the acetabular geometry. Iliopsoas transfer can augment the hip abductor power by an average of one MRC grade. Varus derotation femoral osteotomy is important to re-establish a normal neck-shaft angle and anteversion. The results of pelvic osteotomy are variable and the importance of a posterior acetabular defect is emphasised.