Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 11 - 11
23 Jul 2024
Sarhan M Moreau J Francis S Page P
Full Access

Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population.

The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with Cephalomedullary nails to review and compare Gamma (2013–2017) and TFNA (2017–2023) failure rates and the timing of the failures. Infected and Elective revision to Arthroplasty cases were excluded.

The results are 1034 cases had been included, 784 fixed with TFNA and 250 cases fixed Gamma nails. Out of the 784 patients fixed with TFNA, 19 fixation failed (2.45%). Out of the 250 cases fixed with Gamma nails, 15 fixation failed (6%). Mean days for fixation failure were 323 and 244 days in TFNA and Gamma nails respectively.

We conclude that TFNA showed remarkable less failure rates if compared to Gamma nails. At point of launch, testing was limited and no proof of superiority of TFNA over Gamma nail. Several failures identified with proximal locking aperture in TFNA which can be related to the new design which had Substantial reduction in lateral thickness at compression screw aperture.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 85 - 85
1 May 2017
Folkard S Bloomfield T Page P Wilson D Ricketts D Rogers B
Full Access

Introduction

We used patient reported outcome measures (PROMS) to evaluate qualitative and societal outcomes of trauma.

Methods

We collected PROMs data between Sept 2013 and March 2015 for 92 patients with injury severity score (ISS) greater than 9. We enquired regarding return to work, income and socioeconomic status, dignity and satisfaction and the EQ-5D questionnaire.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 46 - 46
1 May 2017
Page P Lee C Rogers B
Full Access

Background

Fractures of the femoral neck occurring outside the capsule of the hip joint are assumed to have an intact blood supply and hence their conventional management is by fixation rather than arthroplasty. The dynamic hip screw and its variants have been used over many years to fix such fractures but have inherent vulnerabilities; they require an intact lateral femoral cortex, confer a relatively long moment arm to the redistribution of body weight and may cause a stress riser due to the plate with which they are fixed to the femur. Intramedullary devices for fixation of proximal femoral fractures have a shorter moment arm, can be distally locked with reduced perforation of the femoral cortex and are believed to be inherently more stable. For these reasons, a number of surgeons believe them to be superior to the DHS for all extracapsular fractures and their use is now widespread. In this study, we present the usage trends of both devices in extracapsular fractures over the last five years and set these results in the context of patient demographics.

Methods

Our departmental electronic patient management system was used to identify all patients undergoing surgery coded as either DHS or its variants or intramedullary fixation of hip fracture. The patients’ age, sex and American Society of Anaesthesiologists grading were recorded. Comparison between groups was made using appropriate tests in SPSS.