Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 428 - 428
1 Apr 2004
Ohtsuki Y Takai S Yoshino N Kobayashi M Watanabe Y
Full Access

Introduction: Soft tissue balancing remains the most subjective and most artistic of current techniques in total knee arthroplasty. The flexion gap is traditionally measured at approximately 45 degree of hip flexion and 90 degree of knee flexion on the operation table. Despite of aiming equal joint gaps or tensions in flexion and extension, influence of the thigh weight on the flexion gap has not been documented. Therefore, the purpose of this study was to examine the flexion gaps in the 90-90 degree flexed position and the traditional 45-90 degree flexed position of hip-knee joints.

Materials and methods: Thirty patients with osteoarthritic knee underwent total knee arthroplasty. After the PCL sacrifice, soft tissue releases, and bone cuts, the specially designed tenser which has two load cells was employed. 160N was applied to open the joint gaps in the traditional 45-90 degree flexed position and the 90-90 degree flexed position of hip-knee joints.

Results: The flexion gap in the 90-90 degree flexed position of hip-knee joints was 2.1±1.2mm wider than that in the traditional 45-90 degree flexed position of hip-knee joints. The flexion gap had significant difference between the two different hip flexion angles (p< 0.001).

Discussions: In the traditional 45-90 degree flexed position of hip-knee joints on the operation table, the flexion gap is approximately 45 degree to the gravitation and influenced by the thigh weight. To avoid the influence of the thigh weight and obtain equal joint gaps or tensions in flexion and extension, the flexion gap should be checked in the 90-90 degree flexed position of hip-knee joints.