Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 24 - 24
1 May 2013
Nunn T Pratt E Dickens W Bell M Jones S Madan S Fernandes J
Full Access

The Pelvic Support Osteotomy (PSO) or Ilizarov Hip Reconstruction(IHR) is well described for the treatment of septic sequelae of infancy. The purpose of this study was to clinically, functionally and radiographically assess our short-term results of this procedure.

25 patients (16 boys, 9 girls) who had undergone a IHR using the Ilizarov/TSF construct over a period of 10 years for a variety of pathologies were reviewed. The mean age at surgery was 15 years 4 months. The pre-operative diagnoses were SCFE(10), hip sepsis (6), DDH (6) and Perthes (3). All had significant leg length discrepancies, 16 had a painful stiff hip, 6 had a painful mobile hip and 3 had a painless unstable hip. At surgery, a mean measured proximal valgus angle of 51° and a mean extension angle of 15° was achieved. Distal femoral lengthening averaged 4.2 cm and distal varus correction was a mean of 8°. The mean fixator time was 173 days.

At a mean of 2 years and 7 months follow-up the lower-extremity length discrepancy had improved from a mean of 5.6 cm apparent shortening to 2.3 cm. Trendelenberg sign was eliminated in 18/25 cases. Improvements in range of hip movements and gait parameters were observed. Stance time asymmetry, step length asymmetry, pelvic dip and trunk lurch improved significantly. One patient had conversion to a total hip replacement after 7 years, 4 patients required re-do PSO due to remodelling of the proximal osteotomies, two had heterotopic ossification and two had significant knee stiffness due to lack of compliance.

The early results of IHR are encouraging to equalise limb lengths, negate trendelenburg gait, provide a mobile hip with a reasonable axis and the possibility of conversion to THR in the future if needed. Complications need to be anticipated and the effects of remodelling and maintaining adequate knee range of motion must be emphasised.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_11 | Pages 12 - 12
1 Feb 2013
Nunn T Bajaj S Geddes C Wright J Bellamy J Madan S Fernandes J
Full Access

Aim

The use of intraoperative cell salvage as a tool for reducing allogenic transfusion has been demonstrated in pelvic osteotomies. The aims of this audit were to identify any problems or complications with cell salvage, reduction in allogenic transfusion and identify procedures that would benefit.

Methods

The use of cell salvage and allogenic transfusions were prospectively recorded over a 27-month period for all those who had major non spinal surgery looking at whether cell-salvage reduced allogenic transfusions and where cell salvage was used it was matched to procedure, diagnosis and age with cases where it was not used over the same time period.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 10 - 10
1 Feb 2013
Nunn T Horner A Pallister I
Full Access

Introduction

The ability of activated platelets to induce cellular proliferation is well recognised. In a previous diffusion model, platelets combined with Tri-calcium phosphate (TCP) led to an osteoprogenitor mitogenic response followed by cellular differentiation. This study was designed to look at osteoprogenitor responses when cultured directly onto TCP granules combined with activated platelets.

Method

Human osteoprogenitors were loaded onto TCP with activated platelets at a low seeding density and high seeding densities. Cellular proliferation was assessed using the pico-green DNA content analysis. Differentiation towards osteoblastic phenotype was assessed using an alkaline phosphatase assay. RNA extraction, reverse transcription and quantitative real-time polymerase chain reaction was used to assess gene expression for type 1 collagen and osteocalcin. Histological assessment for live/dead staining and alkaline phosphatase was used on cultured granule samples.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 499 - 499
1 Oct 2010
Sharif K Bagga T Nunn T Rehman F
Full Access

The 2007 National Institute for health and Clinical Excellence (NICE) thromboprophylaxis guidelines concerning hip arthroplasty remain contentious. A survey among British Hip Society members was performed to investigate the impact of these guidelines. Information on thromboprophylactic measures before and after guideline publication was gathered in the three categories of Total Hip Replacement (THR), hip fracture and high-risk patients as defined by NICE. The response rate was 185/250 (74%). All responders used thromboprophylaxis, but only 44%, 22% and 7% indicated they were currently acting in accordance with guidance for THR, high risk and hip fracture groups respectively. 19%, 14% and 14% had changed their practice since publication of the guidance in THR, high risk and hip fracture groups respectively. The effects of the NICE guidance in influencing the responders’ thromboprophylactic protocols have been very limited. These results do not appear to endorse the authority of NICE in decisions made in this area.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1197 - 1200
1 Sep 2009
Betts HM Abu-Rajab R Nunn T Brooksbank AJ

We describe the longer term clinical and radiological findings in a prospectively followed series of 49 rheumatoid patients (58 shoulders) who had undergone Neer II total shoulder replacement. The early and intermediate results have been published previously.

At a mean follow-up of 19.8 years (16.5 to 23.8) 14 shoulders survived. Proximal migration of the humeral component was associated with progressive loosening of the glenoid and humeral components, but was independent of the state of the rotator cuff at the time of operation. Despite these changes the range of movement was preserved. Most patients had little or no pain in the shoulder, could sleep undisturbed and could attend to personal hygiene and grooming.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1539 - 1544
1 Nov 2006
Abu-Rajab RB Stansfield BW Nunn T Nicol AC Kelly IG

This study evaluated the effect on movement under load of three different techniques for re-attachment of the tuberosities of the humerus using test sawbones. In the first, the tuberosities were attached both to the shaft and to each other, with one cerclage suture through the anterior hole in the prosthesis. The second technique was identical except for omission of the cerclage suture and in the third the tuberosities were attached to the prosthesis and to the shaft. An orthogonal photogrammetric system allowed all segments to be tracked in a 3D axis system. The humeri were incrementally-loaded in abduction, and the 3D linear and angular movements of all segments were calculated. Displacement between the tuberosities and the shaft was measured.

The first and second techniques were the most stable constructs, with the third allowing greater separation of fragments and angular movement. Separation at the midpoint of the tuberosities was significantly greater using the latter technique (p < 0.05). The cerclage suture added no further stability to the fixation.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 389 - 389
1 Oct 2006
Abu-Rajab R Kelly I Nicol A Stansfield B Nunn T
Full Access

The purpose of this study was to evaluate the effect on movement under load of different techniques of reat-tachment of the humeral tuberosities following 4-part proximal humeral fracture. Biomechanical test sawbones were used. 4-part fracture was simulated and a cemented Neer3 prosthesis inserted. Three different techniques of reattachment of the tuberosities were used – 1)tuberosities attached to the shaft, and to each other through the lateral fins in the prosthesis with one cerclage suture through the anterior hole in the prosthesis, 2)as 1 without cerclage suture, and 3)tuberosities attached to the prosthesis and to the shaft. All methods used a number 5 ethibond suture. Both tuberosities and the shaft had multiple markers attached. Two Digital cameras formed an orthogonal photogrammetric system allowing all segments to be tracked in a 3-D axis system. Humeri were incrementally loaded in abduction using an Instron machine, to a minimum 1200N, and sequential photographs taken. Photographic data was analysed to give 3-D linear and angular motions of all segments with respect to the anatomically relevant humeral axis, allowing intertuberosity and tuberosity-shaft displacement to be measured. Techniques 1 and 2 were the most stable constructs with technique 3 allowing greater separation of fragments and angular movement. True intertuberosity separation at the midpoint of the tuberosities was significantly greater using technique 3 (p< 0.05). The cerclage suture used in technique 2 added no further stability to the fixation. In conclusion, our model suggests that the most effective and simplest technique of reattachment involves suturing the tuberosities to each other as well as to the shaft of the humerus. The cerclage suture appears to add little to the fixation in abduction, although the literature would suggest it may have a role in resisting rotatory movements.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 159 - 159
1 Apr 2005
Abu-Rajab RB Kelly IG Nicol AC Stansfield B Nunn T
Full Access

The purpose of this study was to evaluate the effect on movement under load of different techniques of reattachment of the humeral tuberosities following 4-part proximal humeral fracture.

Biomechanical test sawbones were used. 4-part fracture was simulated and a cemented Neer3 prosthesis inserted. Three different techniques of reattachment of the tuberosities were used – 1)tuberosities attached to the shaft, and to each other through the lateral fins in the prosthesis with one cerclage suture through the anterior hole in the prosthesis, 2)as 1 without cerclage suture, and 3)tuberosities attached to the prosthesis and to the shaft. All methods used a number 5 ethibond suture. Both tuberosities and the shaft had multiple markers attached. Two Digital cameras formed an orthogonal photogrammetric system allowing all segments to be tracked in a 3-D axis system. Humeri were incrementally loaded in abduction using an Instron machine, to a minimum 1200N, and sequential photographs taken. Photographic data was analysed to give 3-D linear and angular motions of all segments with respect to the anatomically relevant humeral axis, allowing intertuberosity and tuberosity-shaft displacement to be measured.

Techniques 1 and 2 were the most stable constructs with technique 3 allowing greater separation of fragments and angular movement. True intertuberosity separation at the midpoint of the tuberosities was significantly greater using technique 3 (p< 0.05). The cerclage suture used in technique 2 added no further stability to the fixation.

In conclusion, our model suggests that the most effective and simplest technique of reattachment involves suturing the tuberosities to each other as well as to the shaft of the humerus. The cerclage suture appears to add little to the fixation in abduction, although the literature would suggest it may have a role in resisting rotatory movements.