Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.Aims
Methods
The gluteus minimus (GMin) and gluteus medius (GMed) have unique structural and functional segments that may be affected to varying degrees, by end-stage osteoarthritis (OA) and normal ageing. We used data from patients with end-stage OA and matched healthy controls to 1) quantify the atrophy of the GMin and GMed in the two groups and 2) describe the distinct patterns of the fatty infiltration in the different segments of the GMin and GMed in the two groups. A total of 39 patients with end-stage OA and 12 age- and sex frequency-matched healthy controls were prospectively enrolled in the study. Fatty infiltration within the different segments of the GMin and the GMed was assessed on MRI according to the semiquantitative classification system of Goutallier and normalized cross-sectional areas were measured.Aims
Methods
Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component.Aims
Methods
Experimental studies indicate that non-steroidal anti-inflammatory drugs (NSAIDs) may have negative effects on fracture healing. This study aimed to assess the effect of immediate and delayed short-term administration of clinically relevant parecoxib doses and timing on fracture healing using an established animal fracture model. A standardized closed tibia shaft fracture was induced and stabilized by reamed intramedullary nailing in 66 Wistar rats. A ‘parecoxib immediate’ (Pi) group received parecoxib (3.2 mg/kg bodyweight twice per day) on days 0, 1, and 2. A ‘parecoxib delayed’ (Pd) group received the same dose of parecoxib on days 3, 4, and 5. A control group received saline only. Fracture healing was evaluated by biomechanical tests, histomorphometry, and dual-energy x-ray absorptiometry (DXA) at four weeks.Objectives
Methods
Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function. A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6).Aims
Materials and Methods
The aim of this randomized trial was to compare the functional outcome of two different surgical approaches to the hip in patients with a femoral neck fracture treated with a hemiarthroplasty. A total of 150 patients who were treated between February 2014 and July 2017 were included. Patients were allocated to undergo hemiarthroplasty using either an anterolateral or a direct lateral approach, and were followed for 12 months. The mean age of the patients was 81 years (69 to 90), and 109 were women (73%). Functional outcome measures, assessed by a physiotherapist blinded to allocation, and patient-reported outcome measures (PROMs) were collected postoperatively at three and 12 months.Aims
Patients and Methods
Dupuytren’s contracture is a benign, myoproliferative condition
affecting the palmar fascia that results in progressive contractures
of the fingers. Despite increased knowledge of the cellular and
connective tissue changes involved, neither a cure nor an optimum
form of treatment exists. The aim of this systematic review was
to summarize the best available evidence on the management of this
condition. A comprehensive database search for randomized controlled trials
(RCTs) was performed until August 2017. We studied RCTs comparing
open fasciectomy with percutaneous needle aponeurotomy (PNA), collagenase
clostridium histolyticum (CCH) with placebo, and CCH with PNA, in
addition to adjuvant treatments aiming to improve the outcome of
open fasciectomy. A total of 20 studies, involving 1584 patients,
were included.Aims
Materials and Methods
Total hip replacement (THR) in children and very young teenagers is experimental since we do not know long-term results in these. We investigated the clinical and radiographic outcomes of THR performed in children and teenage patients identified in the Norwegian Arthroplasty Register We included 111 patients (132 hips) who underwent THR before 20 years of age., together with information on the primary diagnosis, types of implants, and any revisions that required implant change. Radiographs and Harris hip score (HHS) were evaluated for patients that attended clinical follow-up. The mean age at primary THR was 17 (11–19) years, 60% were girls. Mean follow-up time was 14 (3–26) years. The 10-year survival rate after primary THR (with endpoint any revision) was 70%. Survival was better for the patients operated after 1996 (10 y 50% vs 90%). 39 patients had at least 1 revision and 16 patients had 2 or more revisions. In the latest radiographs, osteolysis and atrophy were observed in 19% and 27% of the acetabulae and 21% and 62% of the femurs, respectively. The mean HHS at the final follow-up was 83 (15–100). EQ-5DVAS was 74 (82 in normal population). The clinical scores after THR in these young patients were acceptable, but many revisions had been performed. The bone stock in many patients was poor, which could complicate future revisions.
Cemented femoral stems with force closed fixation
designs have shown good clinical results despite high early subsidence.
A new triple-tapered stem in this category (C-stem AMT) was introduced
in 2005. This study compares this new stem with an established stem
of similar design (Exeter) in terms of migration (as measured using radiostereometric
analysis), peri-prosthetic bone remodelling (measured using dual
energy x-ray densitometry, DXA), Oxford Hip Score, and plain radiographs. A total of 70 patients (70 hips) with a mean age of 66 years
(53 to 78) were followed for two years. Owing to missing data of
miscellaneous reasons, the final analysis represents data from 51
(RSA) and 65 (DXA) patients. Both stems showed a typical pattern
of migration: Subsidence and retroversion that primarily occurred
during the first three months. C-stem AMT subsided less during the
first three months (p = 0.01), before stabilising at a subsidence rate
similar to the Exeter stem from years one to two. The rate of migration
into retroversion was slightly higher for C-stem AMT during the
second year (p = 0.03). Whilst there were slight differences in
movement patterns between the stems, the C-stem AMT exhibits good
early clinical outcomes and displays a pattern of migration and
bone remodelling that predicts good clinical performance. Cite this article:
Many patients with displaced intracapsular femoral neck fractures (IFNF) are treated with hemiarthroplasty (HA) which has been shown superior to internal fixation(IF) the first year after injury. Long term results, however, are sparse. A total of 222 consecutive patients above 60 years, including mentally disabled, with IFNF were randomized to either internal fixation with two parallel screws or hemiarthroplasty, and operated by the surgeon on call. After 5 years, 68 of the 70 surviving patients accepted a follow-up visit. The reviewers were blinded for initial treatment.Introduction
Methods
An experimental rabbit model was used to test the null hypothesis,
that there is no difference in new bone formation around uncoated
titanium discs compared with coated titanium discs when implanted
into the muscles of rabbits. A total of three titanium discs with different surface and coating
(1, porous coating; 2, porous coating + Bonemaster (Biomet); and
3, porous coating + plasma-sprayed hydroxyapatite) were implanted
in 12 female rabbits. Six animals were killed after six weeks and
the remaining six were killed after 12 weeks. The implants with
surrounding tissues were embedded in methyl methacrylate and grinded
sections were stained with Masson-Goldners trichrome and examined
by light microscopy of coded sections.Objectives
Methods
The costs of hip fractures are high. For the individual suffering a hip fracture there are both physical and psychological costs. For society there are costs of medical attention such as hospital treatment, rehabilitation and an increased level of care. We aimed to assess whether total hospital and societal costs for the treatment of elderly patients with displaced femoral neck fractures differ between patients operated with either internal fixation or hemiarthroplasty.
Traditional techniques for the insertion of femoral stems in arthroplasty of the hip in osteopetrosis carry a considerable risk of penetration of the femoral cortex and intra-operative fractures, due to obliteration of the intramedullary cavity and greatly increased stiffness and brittleness of the bone. In order to reduce the risk of such complications we manufactured a customised stem and a computer-based guiding device for the preparation of a cavity within the proximal femur. This system was used successfully in three hips in two patients. We describe the system and the operative technique.
RSA after two years: (table deleted)
In conclusion we found significantly reduced wear for aluminumoxide heads compared to cobalt chrome heads which could be beneficial for young and active patients.
Fracture prevention has so far been studied in patients included on the basis of low bone density, and not after a fracture. In this study the inclusion criteria was a new hip fracture irrespective of bone density. An international, multicenter, randomized, double-blind, placebo-controlled, parallel-group trial (HORIZON-RFT) studied whether the bisphosphonate, zoledronic acid (ZOL) 5 mg, reduced subsequent clinical fractures in men and women ≥50 yrs after a hip fracture.
Hip arthroplasty has its true genesis in 1962 when the Charnley Total Hip was first implanted. The system comprised a stainless steel femoral stem with fixed 22,225mm head articulating against an all polyethylene acetabular cup. Both components were fixed in position with acrylic bone cement. There have been a number of changes in design, materials and surgical technique but the essential concept remains the same. The system was widely used by both senior and junior surgeons. Numerically implantations peaked at ~45,000 per annum in the late1980’s and is still at around ~25,000 per annum in the mid 2000’s. Geographically the system was used in all five continents. Patients varied widely both in age, activity, and diagnosis. It would therefore seem an appropriate vehicle to examine the variations in results of total hip replacement by patient profile, geography, and era of implantation. A search was carried out on the US NCBI website for publications reporting on results with the Charnley system up to the end of 2002, and which comprised a follow-up of more than 10 years, and gave survivorship data. This resulted in 28 papers with 14 countries of origin available for review. For all studies basic data such as age and diagnosis, range implantation dates, likely specific design of prosthesis, origin of study and number in study was either reported or could be deduced. A ten year survivorship was reported in 16 studies for stem and cup and 7 for stem only. If the longest follow-up was considered for each study then 18 reported on stem and cup (9392 hips, implanted 1962–92) and 15 on stem only (4243 hips, implanted 1966–91). A total of 11 studies had four of more points on a survivorship curve, seven with stem and cup, four with stem only. There are a number of points of interest in this data. The first is that with one exception the performance is remarkably consistent as shown by the survivorship curves. There is no significant difference in the survival rates from different centres, countries, and with implantation dates ranging from 1962 through to 1992. Secondly, there appears to have been little or no change in the average age of patients with implant date. There is some evidence to indicate from the 10 year data that failure rate per year is lower in older patients but does not seem to be affected by implantation date. The latter despite the fact that both surgical technique and component design changed over the 30 year implantation period. A further observation is that the failure rate per year is lower in studies with greater numbers of patients. The general conclusion from this review is that the Charnley Total Hip is remarkably consistent in its performance both over time and location of implantation. Its performance also seems to have been affected very little by changes in technique or design.
Conventional non-steroidal anti-inflammatory drugs (NSAIDs) and newer specific cyclo-oxygenase-2 (cox-2) inhibitors are commonly used in musculoskeletal trauma and orthopaedic surgery to reduce the inflammatory response and pain. These drugs have been reported to impair bone metabolism. In reconstruction of the anterior cruciate ligament the hamstring tendons are mainly used as the graft of choice, and a prerequisite for good results is healing of the tendons in the bone tunnel. Many of these patients are routinely given NSAIDs or cox-2 inhibitors, although no studies have elucidated the effects of these drugs on tendon healing in the bone tunnel. In our study 60 female Wistar rats were randomly allocated into three groups of 20. One received parecoxib, one indometacin and one acted as a control. In all the rats the tendo-Achillis was released proximally from the calf muscles. It was then pulled through a drill hole in the distal tibia and sutured anteriorly. The rats were given parecoxib, indometacin or saline intraperitoneally twice daily for seven days. After 14 days the tendon/bone-tunnel interface was subjected to mechanical testing. Significantly lower maximum pull-out strength (p <
0.001), energy absorption (p <
0.001) and stiffness (p = 0.035) were found in rats given parecoxib and indometacin compared with the control group, most pronounced with parecoxib.
Open tibia fractures are often associated with delayed union and non-union. The use of recombinant human bone morphogenetic protein-2 (rhBMP-2) to treat acute, open tibial shaft fractures has been approved in both Europe (InductOs) and the United States (INFUSE Bone Graft). These approvals were based on the results of a prospective, randomized study of 450 patients with open tibia fractures that has already been published (