header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 15 - 15
1 Jul 2022
Putnis S Klasan A Oshima T Grasso S Neri T Coolican M Fritsch B Parker D
Full Access

Abstract

Introduction

MRI has been increasingly used as an outcome measure and proxy for healing and integration after ACL reconstruction (ACLR). Despite this, it has not yet been established what a steady state graft MRI appearance is.

Methodology

MRI and clinical outcome measures were prospectively taken at 1 and minimum 2 years after hamstring autograft ACLR. MRI graft signal was measured using novel reconstructions both parallel and perpendicular to the graft, with lower signal indicative of better healing and expressed as the signal intensity ratio (SIR), and tunnel apertures analysed.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 489 - 494
1 Oct 2019
Klasan A Bäumlein M Dworschak P Bliemel C Neri T Schofer MD Heyse TJ

Objectives

Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies. The purpose of this study was a direct load-to-failure comparison of a double-wedged cementless stem and a short cementless stem in a cadaveric fracture model.

Methods

Eight hips from four human cadaveric specimens (age mean 76 years (60 to 89)) and eight fourth-generation composite femurs were used. None of the cadaveric specimens had compromised quality (mean T value 0.4 (-1.0 to 5.7)). Each specimen from a pair randomly received either a double-wedged stem or a short stem. A materials testing machine was used for lateral load-to-failure test of up to a maximal load of 5000 N.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 86 - 86
1 Dec 2016
Philippot R Boyer B Neri T Farizon F
Full Access

The main causes of total hip arthroplasty (THA) revisions are loosening and instability. Use of a dual mobility cup cemented in a acetabular reconstruction cage device limits the risk of instability and does not hinder the acetabular fixation during THA revisions. The objective of this study was to analyse a retrospective series of 123 THA revisions with antiprotusio cage and dual mobility socket.

Patients and methods: At a mean follow-up of 10 years, we analysed a continuous series of 123 revisions using a reconstruction device (87 Kerboull cross-plates, 12 Burch-Schneider antiprotrusio cages, 24 custom-fit Novae ARM cages associated in all cases with a Novae Stick dual mobility cup cemented into the cage). There were 80 women and 43 males. The mean age at the surgery was 69.2 years old.

PMA score increased from 9.6 +/− 3.06 preoperatively to 14.2 +/− 2. at the follow-up. 9 early dislocations occurred and one late dislocation. At the last follow-up, the X-rays showed nine hardware failures, including one cross-plate fracture, one hook fracture, and one flange fracture. Analysis of the radiological position of the cup showed a mean lowering of 13 mm and a 7 mm lateralisation compared to the preoperative position. 2 revisions for aseptic loosening and 3 for septic loosening were performed.

This study confirms the advantage of dual mobility cups during acetabular reconstruction cemented in antiprotrusio cages as a way to limit, without eliminating, the risk of dislocation. Therefore cemented fixation of dual mobility cups in cages appears to be a reliable short-term option.