Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered. Cite this article:
Historically, the outcomes of knee replacement were evaluated based on implant longevity, major complications and range of motion. Over the last recent years however, there has been an intensively growth of interest in the patient's perception of functional outcome. However, the currently used patient related outcome (PRO) scores are limited by ceiling effects which limit the possibility to distinguish between good and excellent results post knee arthroplasty. The Forgotten Joint Score (FJS) is a new PRO score which is not influenced by ceiling effects, therefore making it the ideal instrument to compare functional outcome between various types of implants. It is based on the thought that the ultimate goal in joint arthroplasty is the ability of a patient to forget their artificial joint in everyday life. The aim of this study is to compare the FJS between patients who undergo TKA and patients who undergo medial UKA at least 12 months post-operatively. We hypothesized that the UKA which is less extensive surgical procedure will present better FJS than TKA, even 12 month postoperative. All patients who underwent medial UKA or TKA were contacted 12 months post-operatively. They were asked to complete the FJS, the Western Ontario and McMasters Universities Osteoarthritis index (WOMAC) and the EuroQol-5D (EQ-5D). A priori power analysis was conducted using two-sample t-test. 64 patients in each group were needed to reach 80% power for detecting a 12 point (SD 24) significant difference on the FJS scale with a two-sided significant level of 0.05. A p-value <0.05 was considered as statistically significant.Introduction
Methods
Chronic uneven distribution of forces over the articular cartilage, which are present in OA, has been shown to be a risk factor for the development of OA. Certain regions of the articular cartilage will be exposed to increased chronic peak loads, whereas other regions encounter a corresponding relative reduction of transmitted forces. This has a well known influence on cartilage viability and is a precursor of degenerative progression. Congruence of joints has an important impact on force distribution across articular surfaces. Therefore, tibiofemoral incongruence could lead to alterations of load distribution and ultimately to progressive degenerative changes. In clinical practice the routine method for evaluation of progressive OA is analysis of joint space width (JSW) using weight bearing radiographs. Recent studies have suggested that JSW has a strong positive correlation with cartilage compression, volume and meniscal extrusion Lateral unicondylar knee arthroplasty (UKA) has gained increasing popularity over the last decade in the treatment of isolated unicompartmental osteoarthritis (OA). However, progressive degenerative alterations of the medial compartment following lateral unicompartmental knee arthroplasty remains a leading cause of revision surgery. Therefore, the purpose of this study is to evaluate the medial compartment congruence (MCC) and joint space width (JSW) alterations following lateral UKA. The MCC of 53 knees following lateral UKA was evaluated on pre- and postoperative radiographs and compared to 41 healthy knees, using an Interative Closest Point (ICP) algorithm. The ICP algorithm calculated the Congruence Index (CI) by performing a rigid transformation that best aligns the digitized tibial and femoral surfaces (figure 1A). Inner, middle and outer JSW was measured by subdividing the medial compartment into four quarters on weight bearing tunnel view radiographs pre- and postoperatively (figure 1B).Introduction
Methods
There are several advantages of unicompartmental knee arthroplasty (UKA) in the treatment of isolated compartment osteoarthritis (OA) compared to the conventional total knee arthroplasty. Although various series report similar survivorship results, the national registries tend to show higher revision rates among the UKA. Persisting, unexplainable pain is a leading cause for UKA revision surgery. Therefore it is essential to investigate the various patient specific characteristics which might influence outcome following UKA in order to minimize revision rates and optimize clinical outcomes. The purpose of this study is to evaluate the influence of the various individual patient factors, including pre-operative radiographic parameters, on the outcome following UKA. 168 consecutive patients who underwent robot assisted UKA (MAKO Tactile Guidance System, MAKO Surgical Corporation, Ft. Lauderdale, FL, USA) were included. The investigated pre- and/or postoperative parameters included gender, BMI, age, type of tibial implant (inlay versus onlay), laterality, state of OA (i.e. Kellgren and Lawrence grade) of the operated and non-operated compartment and mechanical axis alignment. Pre-operatively and at a minimum of 1 year (average 1.97 years, range 1 – 4.2 years) following surgery, patients were asked to complete the Western Ontario and McMaster Universities Arthritis Index (WOMAC) questionnaire. It is subdivided in three separate scales (i.e. pain, stiffness and function). A score of 0 represents the best possible outcome and a score of 100 the worst. A p-value <0.05 was considered statistically significant.Introduction
Methods
Highly cross-linked polyethylene (HCLPE) was introduced to reduce wear and osteolysis in total hip arthroplasty (THA). There is no reported data regarding wear rates and clinical performance of Crossfire HCLPE (Stryker, Mahwah, New Jersey) in young and active patients. The purpose of this prospective study is to assess minimum 10-year wear rates and survivorship of Crossfire in young and active patients. Between January 2001 to December 2003, 52 consecutive THAs (43 patients; 26 males and 17 females), 55 years and younger, with an average University of California Los Angeles activity (UCLA) score of 7.3 ± 1.5 (5 – 10) at the time of surgery were prospectively followed. The mean age of patients was 47.4 ± 7.8 years old (range 24 to 55 years). Indication for surgery included osteoarthritis in all cases. All operations were performed by the senior surgeon via a posterolateral approach. All components were non-cemented SecurFit femoral stem, 28 mm Cobalt-Chromium (Co-Cr) femoral head, and Trident PSL cup with Crossfire HCLPE acetabular liner (Stryker, Mahwah, New Jersey). At minimum 10-years follow-up (mean 11.5 ± 0.94 years), wear rates were assessed using the Roman software. Hospital for Special Surgery (HSS) scores and survivorship data were analyzed.Background
Material and Methods
Progressive degenerative changes in the medial
compartment of the knee following lateral unicompartmental arthroplasty
(UKA) remains a leading indication for revision surgery. The purpose
of this study is to evaluate changes in the congruence and joint
space width (JSW) of the medial compartment following lateral UKA.
The congruence of the medial compartment of 53 knees (24 men, 23
women, mean age 13.1 years; Our data suggest that a well conducted lateral UKA may improve
the congruence and normalise the JSW of the medial compartment,
potentially preventing progression of degenerative change. Cite this article:
In patients with a tumour affecting the distal
ulna it is difficult to preserve the function of the wrist following extensive
local resection. We report the outcome of 12 patients (nine female,
three male) who underwent excision of the distal ulna without local
soft-tissue reconstruction. In six patients, an aggressive benign
tumour was present and six had a malignant tumour. At a mean follow-up
of 64 months (15 to 132) the mean Musculoskeletal Tumour score was
64% (40% to 93%) and the mean DASH score was 35 (10 to 80). The
radiological appearances were satisfactory in most patients. Local
recurrence occurred in one patient with benign disease and two with
malignant disease. The functional outcome was thus satisfactory
at a mean follow-up in excess of five years, with a relatively low
rate of complications. The authors conclude that complex reconstructive
soft-tissue procedures may not be needed in these patients. Cite this article:
Computer assisted surgery (CAS) systems have been shown to improve alignment accuracy in total knee arthroplasty (TKA), yet concerns regarding increased costs, operative times, pin sites, and the learning curve associated with CAS techniques have limited its widespread acceptance. The purpose of this study was to compare the alignment accuracy of an accelerometer-based, portable navigation device (KneeAlignÒ 2) to a large console, imageless CAS system (AchieveCAS). Our hypothesis is that no significant difference in alignment accuracy will be appreciated between the portable, accelerometer-based system, and the large-console, imageless navigation system. 62 consecutive patients, and a total of 80 knees, received a posterior cruciate substituting TKA using the Achieve CAS computer navigation system. Subsequently, 65 consecutive patients, and a total of 80 knees, received a posterior cruciate substituting TKA using the KneeAlignÒ 2 to perform both the distal femoral and proximal tibial resections (femoral guide seen in Figure 1, and tibial guide seen in Figure 2). Postoperatively, standing AP hip-to-ankle radiographs were obtained for each patient, from which the lower extremity mechanical axis, tibial component varus/valgus mechanical alignment, and femoral component varus/valgus mechanical alignment were digitally measured. Each measurement was performed by two, blinded independent observers, and interclass correlation for each measurement was calculated. All procedures were performed using a thigh pneumatic tourniquet, and the total tourniquet time for each procedure was recorded.Introduction
Methods
We measured the plasma 25-hydroxyvitamin D3 (25(OH)D3) levels in 62 consecutive Caucasian patients undergoing total hip replacement for osteoarthritis. The patients were divided into two groups based on whether they were vitamin D sufficient or deficient. The groups were matched for age, gender and the American Society of Anaesthesiologists (ASA) grade. The prevalence of vitamin D deficiency in our patients was comparable with recent population-based studies performed in the United Kingdom. Patients with vitamin D deficiency had lower pre-operative Harris hip scores (Mann-Whitney test, p = 0.018) and were significantly less likely to attain an excellent outcome from total hip replacement (chi-squared test, p = 0.038). Vitamin D levels were found to positively correlate with both pre- and post-operative Harris hip scores. These results warrant further study of vitamin D deficiency in patients undergoing joint replacement as it is a risk factor for a suboptimal outcome which is relatively simple and cheap to correct.
We undertook a prospective randomised controlled trial to investigate the efficacy of autologous retransfusion drains in reducing the need for allogenic blood requirement after unilateral total knee replacement. We also monitored the incidence of post-operative complications. There were 86 patients in the control group, receiving standard care with a vacuum drain, and 92 who received an autologous drain and were retransfused postoperatively. Following serial haemoglobin measurements at 24, 48 and 72 hours, we found no difference in the need for allogenic blood between the two groups (control group 15.1%, retransfusion group 13% (p = 0.439)). The incidence of post-operative complications, such as wound infection, deep-vein thrombosis and chest infection, was also comparable between the groups. There were no adverse reactions associated with the retransfusion of autologous blood. Based on this study, the cost-effectiveness and continued use of autologous drains in total knee replacement should be questioned.
Schwannomas are the most common tumours of the sheath of peripheral nerves. The clinical diagnosis is usually straightforward, but may be delayed for many years in a schwannoma of the posterior tibial nerve. The symptoms are often attributed to entrapment neuropathy or to lumbosacral radiculopathy. We describe 25 patients with a schwannoma of the posterior tibial nerve. Only three were diagnosed within a year of presentation. The mean time to diagnosis was 86.5 months with a median of 48 months (2 to 360). All the patients complained of pain, which was felt specifically in the sole of the foot in 18. A Tinel sign was detected in all 25 patients. MRI confirmed the diagnosis in all the cases in which it had been undertaken. Surgical resection of the lesion abolished the neuropathic pain. In patients with a long history of neuropathic pain in the lower limb in whom lumbar and pelvic lesions have been excluded, a benign tumour of the sheath of a peripheral nerve may explain the symptoms. Surgical resection of the tumour is safe and effective.