Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 115 - 115
1 May 2012
A. H R. A D. C N. B
Full Access

Introduction

Cement pressurisation in the distal humerus is technically difficult due to the anatomy of the humeral intramedullary (IM) cavity. Conventional cement restrictors often migrate proximally or leak, reducing the effect of pressurisation during implantation. Theoretically with a better cement bone interdigitation, the longevity of the elbow replacement can be improved. The aim of this cadaveric study was to evaluate the usefulness of a novel technique for cementation.

Method

Eight paired fresh frozen cadaveric elbows were randomly allocated to conventional cementing techniques or cementing using a paediatric foley catheter as a temporary restrictor. The traditional cementing technique consisted of canal preparation using irrigation, brushing and drying prior to cementation, with no use of a cement restrictor. The new technique involved same canal preparation but prior to cementation a size 8 foley catheter was introduced and the balloon inflated to act as a temporary cement restrictor. The humeri were cut into 10mm sections. Each slice was photographed and radiographed. This dual imaging technique was used to establish the best methodology for evaluation of cement penetration. Cement penetration was calculated as a ratio of the area of intra-medullary cavity occupied by the cement.