Hada M Mizu-uchi H Okazaki K Murakami K Kaneko T Higaki H Nakashima Y

Aims

This study aims to investigate the effects of posterior tibial slope (PTS) on knee kinematics involved in the post-cam mechanism in bi-cruciate stabilized (BCS) total knee arthroplasty (TKA) using computer simulation.

Methods

In total, 11 different PTS (0° to 10°) values were simulated to evaluate the effect of PTS on anterior post-cam contact conditions and knee kinematics in BCS TKA during weight-bearing stair climbing (from 86° to 6° of knee flexion). Knee kinematics were expressed as the lowest points of the medial and lateral femoral condyles on the surface of the tibial insert, and the anteroposterior translation of the femoral component relative to the tibial insert.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 122 - 122
1 Apr 2019
Okazaki K Mizu-uchi H Hamai S Akasaki Y Nakashima Y
Full Access

Regaining the walking ability is one of the main purposes of total knee arthroplasty (TKA). Improving the activities of daily living is a key of patient satisfaction after TKA. However, some patients do not gain enough improvement of ADL as they preoperatively expected, and thus are not satisfied with the surgery. The purpose of this study is to clarify the relationship between preoperative and postoperative physical functional status and whether preoperative scoring can predict the postoperative walking ability. Consecutive 136 patients who underwent total knee arthroplasty for osteoarthritis were prospectively assessed. The average age (±SD) was 74±7.7 and 74% of the patients was female. Berg Balance Scale (BBS) was assessed preoperatively and one year after the surgery. The time needed for 10m walking, muscle power for knee extension and flexion, visual analog scale (VAS) for pain in walking, and necessity of canes in walking were also assessed at one year after the surgery. Multivariate correlation analysis was performed for each parameter. Speaman rank correlation coefficient revealed that preoperative BBS was significantly correlated with the time needed for 10m walking (ρ=0.66, p<0.001). Logistic regression analysis also revealed that preoperative BBS is also correlated with the necessity for canes in walking one year after the surgery. The cut-off value of preoperative BBS for the necessity of canes in walking by ROC curve analysis was 48 points with 79% in sensitivity and 80% in specificity. The muscle powers were also weakly correlated with the walking ability at one year after the surgery, but VAS for pain was not. The study indicated that preoperative physical balance could predict the ability of walking one year after TKA regardless of the reduction of pain. It is suggested that surgery should be recommended before the physical balance function deteriorates to achieve the better walking ability after the TKA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 134 - 134
1 Jan 2016
Kuwashima U Tashiro Y Okazaki K Mizu-uchi H Hamai S Okamoto S Iwamoto Y
Full Access

«Purpose»

High tibial osteotomy (HTO) is a useful treatment option for osteoarthritis of the knee. Closing-wedge HTO (CW-HTO) had been mostly performed previously, but the difficulties of surgical procedure when total knee arthroplasty (TKA) conversion is needed are sometimes pointed out because of the severe deformity in proximal tibia. Recently, opening-wedge HTO (OW-HTO) is becoming more popular, but the difference of the two surgical techniques about the influence on proximal tibia deformity and difficulties in TKA conversion are not fully understood. The purpose of this study was to compare the influence of two surgical techniques with CW-HTO and OW-HTO on the tibial bone deformity using computer simulation and to assess the difficulties when TKA conversion should be required in the future.

«Methods»

In forty knees with medial osteoarthritis, the 3D bone models were created from the series of 1 mm slices two-dimensional contours using the 3D reconstruction algorithm. The 3-D imaging software (Mimics, materialize NV, Leuven, Belgium) was applied and simulated surgical procedure of each CW-HTO and OW-HTO were performed on the same knee models. In CWHTO, insertion level was set 2cm below the medial joint line [Fig.1]. While in OW-HTO, that was set 3.5cm below the medial joint line and passed obliquely towards the tip of the fibular head [Fig.2]. The correction angle was determined so that the postoperative tibiofemoral angle would be 170 degrees. The distance between the center of resection surface and anatomical axis, and the angle of anatomical axis and mechanical axis were measured in each procedure. Secondly, a simulated TKA conversion was operated on the each tibial bone models after HTO [Fig.3]. The distance between the nearest points of tibial implant and lateral cortical bone was assessed as the index of the bone-implant interference.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 25 - 25
1 Jan 2016
Hamai S Okazaki K Mizu-uchi H Shimoto T Higaki H Iwamoto Y
Full Access

Introduction

Controversy still exists as to whether total knee arthroplasty (TKA) provides reproducible knee kinematics during activities. In this study, we evaluated the in vivokinematics of stair-climbing after TKA using a 3D-to-2D model-to-image registration technique.

Patients and Methods

A total of twenty four knees in nineteen patients following cruciate-retaining (CR) or posterior-stabilized (PS) TKA were randomly included in the study. The twenty-four knees included 22 female knees and 2 male knees in patients aged 73 years. The pre-operative diagnosis was osteoarthritis in 22 knees and rheumatoid arthritis in 2 knees. The average follow-up period after surgery was 29 months, and average post-operative knee extension/flexion angle was 2°/121°. The average knee score was 93 and the average functional score was 77. Continuous sagittal radiological images were obtained during stair-climbing for each patient using a large flat panel detector. Anteroposterior (AP) tibiofemoral position, implant flexion, and axial rotation angles were determined in three dimensions using a 3D-to-2D model-to-image registration technique. In CR TKA, the minimum distances between the femoral trochlea and the intercondylar eminence of the tibial insert were measured using a CAD software program. In PS TKA, the minimum distances between the femoral cam and the posterior aspect of the tibial post and between the femoral trochlea and the anterior aspect of the tibial post were measured.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 47 - 47
1 Jan 2016
Mizu-uchi H Okazaki K D'Lima D Hamai S Okamoto S Iwamoto Y Matsuda S
Full Access

Introduction

Using the tibial extramedullary guide needs meticulous attention to accurately align the tray in total knee arthroplasty (TKA). We previously reported the risk for varus tray alignment if the anteroposterior (AP) axis of the ankle was used for the rotational direction of the guide. The purpose of our study was to determine whether aligning the rotational direction of the guide to the AP axis of the proximal tibia reduced the incidence of varus tray alignment when compared to aligning the rotational direction of the guide to the AP axis of the ankle.

Materials and Methods


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 101 - 101
1 Jan 2016
Okamoto S Mizu-uchi H Okazaki K Hamai S Tashiro Y Nakahara H Kuwashima U
Full Access

Introduction

Radiographs and computed tomography (CT) images are used for the preoperative planning in total knee arthroplasty (TKA), however, these two-dimensional (2D) measurements are affected easily by limb position and scanning direction relative to three-dimensional (3D) bone model analyses. The purpose of our study was to compare these measurements to evaluate the factors affecting the difference.

Patients and Methods

A total of 75 osteoarthritis knees before primary TKA were assessed. The full-length weight-bearing anteroposterior radiograph and CT slices were used for the 2D measurement. Three-dimensional measurement used 3D bone model reconstructed from the CT data and the coordinate system as the previous reports (Figure 1). We measured FVA (femoral valgus angle), CRA (the angle between the posterior condylar line <PC-L> and the clinical epicondylar axis <CEA>), and SRA (the angle between the PC-L and the surgical epicondylar axis <SEA>). Intra- and inter-observer reliabilities were assessed by intraclass correlation coefficients (ICC), and the differences between the 2D and the 3D measurements (Differences) were evaluated. In addition, we evaluated whether preoperative factors (preoperative extension angle, HKA, BMI and CT scanning direction) affected the differences between the 3D and the 2D measurements. Computer simulation was used to examine the influences of CT scanning direction.


Bone & Joint Research
Vol. 4, Issue 8 | Pages 128 - 133
1 Aug 2015
Kuwashima U Okazaki K Tashiro Y Mizu-Uchi H Hamai S Okamoto S Murakami K Iwamoto Y

Objectives

Because there have been no standard methods to determine pre-operatively the thickness of resection of the proximal tibia in unicompartmental knee arthroplasty (UKA), information about the relationship between the change of limb alignment and the joint line elevation would be useful for pre-operative planning. The purpose of this study was to clarify the correlation between the change of limb alignment and the change of joint line height at the medial compartment after UKA.

Methods

A consecutive series of 42 medial UKAs was reviewed retrospectively. These patients were assessed radiographically both pre- and post-operatively with standing anteroposterior radiographs. The thickness of bone resection at the proximal tibia and the distal femur was measured radiographically. The relationship between the change of femorotibial angle (δFTA) and the change of joint line height, was analysed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 37 - 37
1 Sep 2012
Patil S Manning M Mizu-uchi H Ezzet K D'Lima D
Full Access

Introduction

It is well known that total knee arthroplasty (TKA) does not preserve normal knee kinematics. This outcome has been attributed to alteration of soft-tissue balance and differences between the geometry of the implant design and the normal articular surfaces. Bicompartmental knee arthroplasty (BKA) has been developed to replace the medial and anterior compartments, while preserving the lateral compartment, the anterior cruciate ligament (ACL), and the posterior cruciate ligament (PCL). In a previous study, we reported that unicompartmental knee arthroplasty did not significantly change knee kinematics and attributed that finding to a combination of preservation of soft-tissue balance and minimal alteration of joint articular geometry (Patil, JBJS, 2007). In the present study, we analyzed the effect of replacing trochlear surface in addition to the medial compartment by implanting cadaver knees with a bicompartmental arthroplasty design. Our hypothesis was that kinematics after BCKA will more closely replicate normal kinematics than kinematics after TKA.

Methods

Eight human cadaveric knees underwent kinematic analysis with a surgical navigation system. Each knee was evaluated in its normal intact state, then after BKA with the Deuce design (Smith & Nephew, Memphis, TN), then after ACL sacrifice, and finally after implanting a PCL-retaining TKA (Legion, Smith & Nephew). Knees were tested on the Oxford knee rig, which simulates a quadriceps-driven dynamic deep knee bend. Tibiofemoral rollback and rotation and patellofemoral shift and tilt were recorded for each condition and compared using repeated measures ANOVA for significance.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 37 - 37
1 Jun 2012
Mizu-Uchi H Flores-Hernandez C Colwell C Steklov N Matsuda S Iwamoto Y D'Lima D
Full Access

INTRODUCTION

Knee contact force during activities after total knee arthroplasty (TKA) is very important, since it directly affects component wear and implant loosening. While several computational models have predicted knee contact force, the reports vary widely based on the type of modeling approach and the assumptions made in the model. The knee is a complex joint, with three compartments of which stability is governed primarily by soft tissues. Multiple muscles control knee motion with antagonistic co-contraction and redundant actions, which adds to the difficulty of accurate dynamic modeling. For accurate clinically relevant predictions a subject-specific approach is necessary to account for inter-patient variability.

METHODS

Data were collected from 3 patients who received custom TKA tibial prostheses instrumented with force transducers and a telemetry system. Knee contact forces were measured during squatting, which was performed up to a knee flexion angle that was possible without discomfort (range, 80–120°). Skin marker-based video motion analysis was used to record knee kinematics. Preoperative CT scans were reconstructed to extract tibiofemoral bone geometry using MIMICS (Materialise, Belgium). Subject-specific musculoskeletal models of dynamic squatting were generated in a commercial software program (LifeMOD, LifeModeler, USA). Contact was modeled between tibiofemoral and patellofemoral articular surfaces and between the quadriceps and trochlear groove to simulate tendon wrapping. Knee ligaments were modeled with nonlinear springs: the attachments of these ligaments were adjusted to subject-specific anatomic landmarks and material properties were assigned from published reports.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 436 - 436
1 Nov 2011
Matsuda S Mizu-uchi H Miura H Iwamoto Y
Full Access

Total knee arthroplasty (TKA) has become one of the most successful procedures in orthopedics, and its survival rates are reportedly greater than 90% after 15 years.

Malpositioning of the component, however, can lead to various failures, such as aseptic loosening, instability, polyethylene wear, and patellar dislocation. Navigation systems for TKA have been developed to improve postoperative alignment. Many clinical and experimental studies of these navigation systems have shown that the accuracy of implanted components has improved.

We have compared the alignment of 150 total knee replacements implanted using a computed tomography-based navigation system and using the conventional alignment guide system when performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs and computed tomography scans. For the navigated group, the average hip-knee-ankle angle, the femoral component angle to the femoral mechanical axis, and the tibial component angle to the mechanical tibial axis were 179.5, 89.4 and 89.7 degrees. The rotational femoral and tibial component angles to the planning axis were 0.6 and 0.3 degrees. The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with CT-based navigation system, especially with respect to rotational alignment.

Recently, we established a new method for 3D reconstruction from postoperative CT images in order to accurately measure the alignment of the component relative to any designed plane. The results showed that the discrepancy between the two-dimensional and three-dimensional evaluations was 0.3 ± 1.8 (−2.7–3.4) degrees.

The coronal femoral angle for 36 knees (97.3%) and the coronal tibial angle for all the 37 knees (100%) were obtained within 3 degrees from the optimal angle. It is possible to measure the postoperative alignment for TKA more accurately on the basis of the defining plane. Three-dimensional analysis is necessary to evaluate the accuracy of the navigation system.

We conclude that navigation system is a very useful tool for achieving proper postoperative alignment. Controversy still exists regarding accuracy in rotational alignment with image-free navigation, but our results showed that CT-based system significantly improved accuracy of rotational alignment. We should keep using and improving the systems to establish more simplified and accurate systems.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1025 - 1031
1 Aug 2008
Mizu-uchi H Matsuda S Miura H Okazaki K Akasaki Y Iwamoto Y

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans.

The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8° (174.2° to 188.3°), 88.5° (84.0° to 91.8°) and 89.7° (86.3° to 95.1°), respectively for the conventional group and 180.8° (178.2° to 185.1°), 89.3° (85.8° to 92.0°) and 89.9° (88.0° to 93.0°), respectively for the navigated group.

The mean sagittal femoral component angle was 85.5° (80.6° to 92.8°) for the conventional group and 89.6° (85.5° to 94.0°) for the navigated group.

The mean rotational femoral and tibial component angles were −0.7° (−8.8° to 9.8°) and −3.3° (−16.8° to 5.8°) for the conventional group and −0.6° (−3.5° to 3.0°) and 0.3° (−5.3° to 7.7°) for the navigated group.

The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.