header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 31 - 31
1 Dec 2017
Uchiyama K Kanda H Yamaguchi T Ibe S Sakurai K Nihonyanagi S Minegishi Y Ikeda S Kanou Y Fukushima K Takahira N Takaso M
Full Access

Aim

We used a polymerase chain reaction (PCR) lateral flow assay1) to rapidly diagnose joint infection. We evaluated the usefulness of multiplex-PCR (PCR lateral flow assay: PCR-LF) using detailed clinical data.

Method

A total of 35 synovial fluid samples were collected from 26 patients in whom bacterial infection was suspected, including 22 from knee joints, 11 from hip joints, and 2 from other joints. After purifying the DNA from the samples, multiplex PCR targeting two MRSA-associated genes (femA and mecA) and the bacterial 16S rRNA gene was performed. Amplified gene fragments were specifically detected with DNA probes immobilized on stick devices through DNA-DNA hybridization and visualization, enabling diagnosis of MRSA, MSSA, MRCNS, gram-positive, and/or gram-negative bacterial infection. Genetic identification of bacteria by determining the 16S rRNA gene sequence was also performed using multiplex PCR-positive samples. Finally, the usefulness of our PCR-LF method was evaluated using detailed clinical data.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 97 - 97
1 Dec 2017
Ikeda S Uchiyama K Kishino S Nakamura M Yoshida K Minegishi Y Sugo K Fukushima K Takahira N Kitasato H Takaso M
Full Access

Aim

The preparation of antibiotic-containing polymethyl methacrylate (PMMA), as spacers generates a high polymerization heat, which may affect their antibiotic activity; it is desirable to use bone cement with a low polymerization heat. Calcium phosphate cement (CPC) does not generate heat on polymerization, and comparative elution testings are reported that vancomycin (VCM)-containing CPC (VCM-CPC) exceeded the antibiotic elution volume and period of PMMA (VCM-PMMA). Although CPC alone is a weak of mechanical property spacer, the double-layered, PMMA-covered CPC spacer has been created and clinically used in our hospital. In this study, we prepared the double-layered spacers: CPC covered with PMMA and we evaluated its elution concentration, antimicrobial activity and antibacterial capability.

Method

We prepared spherical, double-layered, PMMA-coated (CPC+PMMA; 24 g CPC coated with 16 g PMMA and 2 g VCM) and PMMA alone (40 g PMMA with 2 g VCM) spacers (5 each). In order to facilitate VCM elution from the central CPC, we drilled multiple holes into the CPC from the spacer surface. Each spacer was immersed in phosphate buffer (1.5 mL/g of the spacer), and the solvent was changed daily. VCM concentrations were measured on days 1, 3, 7, 14, 28, 56, and 84. Antimicrobial activity against MRSA and MSSA was evaluated by the broth microdilution method. After measuring all the concentration, the spacers were compressed at 5 mm/min and the maximum compressive load up to destruction was measured.