Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 30 - 30
1 Dec 2014
Nortje M Hussey D McLennan-Smith R Dymond I Grobler G Dower B Bragdon C Muratoglu O Malchau H
Full Access

Introduction:

The ASR™ Articular Surface Replacement and ASR™ XL Metal-on-Metal systems were recalled due to high revision rates at five years. A worldwide clinical follow-up of patients was initiated. This paper summarizes current findings in South Africa (SA) in comparison with those outside SA (OSA).

Methods:

Patients were followed annually, or until revision, from 10 clinical centers worldwide. Data collected includes demographic, surgical, radiographic, blood metal ion levels, and patient reported outcome measures (PROM).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 62 - 62
1 Aug 2013
McLennan-Smith R
Full Access

It is estimated that 15 % of the population is allergic to metal, most commonly to Nickel, which is a common component of the alloys in most knee and hip arthroplasties. It would therefore be expected that allergy to metal is a frequent form of implant failure – but very little is reported in the literature. With the recent concerns about metal-on-metal bearings and metal ion issues, there has been renewed interest in metal allergy – with the Australian Joint Registry 2010 reporting it as a causative factor in 7 % of Hip Resurfacing revisions.

With over 200 BHR and 571 ASR Hip Resurfacing arthroplasties in my series from 2001, I have identified only 1 patient with implant failure due to metal allergy.

In 2010 two Total Knee Arthroplasty patients presented with pain and strongly positive Melisa allergy tests – these patients were revised to Titanium coated implants resulting in a complete relief of symptoms.

This paper will analyse the problem of metal sensitivity, the investigation and management of the allergic patient who has, or requires, joint arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 8 - 8
1 Mar 2012
Cobb A Isaac G McLennan-Smith R Oakeshott R Siebel T
Full Access

Introduction

A metal ion study was undertaken in patients who had received an articular surface replacement. The design of these components is optimised in line with lubrication theory and produces low levels of wear in hip joint simulators.

Methods

Patients were recruited in four centres. Whole blood samples were analysed for metal ion levels using high resolution ICP-MS (inductively coupled plasma mass spectrophotometry). A total of 75 patients was enrolled into the study and 65 and 47 patients were assessed after 12 and 24 months implantation respectively. Results are included irrespective of clinical outcome.