Intracapsular neck of femur fractures are one of the most common injuries seen in Orthopaedics. When the fracture is amenable to internal fixation there are 2 main treatment options, namely multiple cannulated hip screws (MCS) and 2-hole sliding hip screws (SHS). In this retrospective study we examine the outcomes associated with these two methods of internal fixation. At present there is little consensus regarding which treatment should be used 161 patients were found to have suffered intracapsular neck of femur fracture treated with either SHS or MCS fixation over a 5 year period from April 2009 to April 2014, allowing at least 1 year follow up following injury. The patients imaging and clinical notes were then reviewed to ascertain the outcome of their treatment and any complications.Background
Methods
Statement of purpose. Cement fixation of total knee replacement (TKR) is commonly cited as being the gold standard, with better long-term survival rates when compared to uncemented fixation so the authors set out to analyse the longterm survivorship without aseptic loosening in a series of 471 uncemented TKR. A consecutive single surgeon series of patients undergoing routine follow up after a hydroxyapatite coated, uncemented and cruciate retaining TKR performed from 1992 to 1995 were analysed. All patients were invited for clinical review and radiological assessment. Revision of the TKR for aseptic loosening was the primary outcome. Secondary outcomes included Knee Society Score (0–200), range of movement, secondary surgical interventions and the presence of polyethylene wear or osteolysis on plain radiography. 471 TKRs were performed in 356 patients (115 bilateral). 432 TKRs were accounted for through follow up. 39 TKRs in 31 pts were lost to follow-up representing 8% who had a mean KSS of 176 at 10 yr f/u. Mean f/u time period was 16.4 yrs (range 15.1–18.5 yrs). Average age at f/u was 81 yrs. 11 TKR had been revised for aseptic loosening. 19 TKRs in 19 patients had had revision of femoral/tibial components for any reason. A further 7 TKRs had undergone polyethylene insert exchange leaving an overall revision rate of 9% or 91% survival without revision. Survivorship without aseptic loosening was 96% (95%CI of 91.9–98.1%) at up to 18 years. A competing risks analysis was undertaken in order to avoid overestimation of survivorship adjusted for the competing risk of death within the study group. This analysis estimated a cumulative risk of revision for aseptic loosening at 18 years of 4.5%. Mean KSS was 176 (SD 21.5). Mean range of movement was 113 degrees of flexion.Methods
Results
The aim of this study was to determine the correlation between body weight and fracture union for displaced intracapsular fracture neck of femur treated by closed reduction and internal fixation. A total of 197 patients with displaced intracapsular fracture of neck of femur, all of whom have been treated with closed reduction and internal fixation, were studied. The mean age was 71 years and 79% were female. Patients were followed up until fracture endpoint (union or non-union) with minimum follow up of 200 days.Objective
Patients and methods
A consecutive series of patients with a hydroxyapatite-coated
uncemented total knee replacement (TKR) performed by a single surgeon
between 1992 and 1995 was analysed. All patients were invited for
clinical review and radiological assessment. Revision for aseptic
loosening was the primary outcome. Assessment was based on the Knee
Society clinical score (KSS) and an independent radiological analysis.
Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients
were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in
31 patients lost to follow-up had a mean KSS of 176 (148 to 198)
at a mean of ten years. There were revisions in 26 TKRs (5.5%),
of which 11 (2.3%) were for aseptic loosening. Other further surgery
was carried out on 49 TKRs (10.4%) including patellar resurfacing
in 20, arthrolysis in 19, manipulation under anaesthetic in nine
and extensor mechanism reconstruction in one. Survivorship at up to 18 years without aseptic loosening was
96% (95% confidence interval 91.9 to 98.1), at which point the mean
KSS was 176 (134 to 200). Of 110 knees that underwent radiological
evaluation, osteolysis was observed in five (4.5%), one of which
was revised. These data indicate that uncemented hydroxyapatite-coated TKR
can achieve favourable long-term survivorship, at least as good
as that of cemented designs.
Radiographic analysis suggests that the position of the screws on the AP view (superior, middle, inferior or spread) did not alter the outcome significantly. However three factors were related to lower risk of non-union on the lateral view: the closer the middle screw to the center of the head (p<
0.04), the more anterior the anterior screw (p<
0.008), and the greater the ‘spread’ between the anterior and posterior screws (p<
0.005).