Advertisement for orthosearch.org.uk
Results 1 - 20 of 40
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 56 - 56
2 Jan 2024
Kaneko Y Minehara H Sonobe T Kameda T Sekiguchi M Matsushita T Konno S
Full Access

The Masquelet technique is a variable method for treating critical-sized bone defects, but there is a need to develop a technique for promoting bone regeneration. In recent studies of bone fracture healing promotion, macrophage-mesenchymal stem cell (MSC) cross-talk has drawn attention. This study aimed to investigate macrophage expression in the induced membrane (IM) of the Masquelet technique using a mouse critical-sized bone defect model.

The study involved a 3-mm bone defect created in the femur of mice and fixed with a mouse locking plate. The Masquelet (M) group, in which a spacer was inserted, and the Control (C) group, in which the defect was left intact, were established. Additionally, a spacer was inserted under the fascia of the back (B group) to form a membrane due to the foreign body reaction. Tissues were collected at 1, 2, and 4 weeks after surgery (n=5 in each group), and immunostaining (CD68, CD163: M1, M2 macrophage markers) and RT-qPCR were performed to investigate macrophage localization and expression in the tissues.

The study found that CD68-positive cells were present in the IM of the M group at all weeks, and RT-qPCR showed the highest CD68 expression at 1 week. In addition, there was similar localization and expression of CD163. The C group showed lower expression of CD68 and CD163 than the M group at all weeks. The B group exhibited CD68-positive cells in the fibrous capsule and CD163-positive cells in the connective tissue outside the capsule, with lower expression of both markers compared to the M group at all weeks.

Macrophage expression in IM in M group had different characteristics compared to C group and B group. These results suggest that the IM differs from the fibrous capsules due to the foreign body reaction, and the macrophage-MSC cross-talk may be involved in Masquelet technique.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 34 - 34
4 Apr 2023
Kaneko Y Minehara H Nakamura M Sekiguchi M Matsushita T Konno S
Full Access

Recent researches indicate that both M1 and M2 macrophages play vital roles in tissue repair and foreign body reaction processes. In this study, we investigated the dynamics of M1 macrophages in the induced membrane using a mouse femur critical-sized bone defect model.

The Masquelet method (M) and control (C) groups were established using C57BL/6J male mice (n=24). A 3mm-bone defect was created in the right femoral diaphysis followed by a Kirschner wire fixation, and a cement spacer was inserted into the defect in group M. In group C, the bone defect was left uninserted. Tissues around the defect were harvested at 1, 2, 4, and 6 weeks after surgery (n=3 in each group at each time point). Following Hematoxylin and eosin (HE) staining, immunohistochemical staining (IHC) was used to evaluate the CD68 expression as a marker of M1 macrophage. Iron staining was performed additionally to distinguish them from hemosiderin-phagocytosed macrophages.

In group M, HE staining revealed a hematoma-like structure, and CD68-positive cells were observed between the spacer and fibroblast layer at 1 week. The number of CD68-positive cells decreased at 2 weeks, while they were observed around the new bone at 4 and 6 weeks. In group C, fibroblast infiltration and fewer CD68-positive cells were observed in the bone defect without hematoma-like structure until 2 weeks, and no CD68-positive cells were observed at 4 and 6 weeks. Iron staining showed hemosiderin deposition in the surrounding area of the new bone in both groups at 4 and 6 weeks. The location of hemosiderin deposition was different from that of macrophage aggregation.

This study suggests that M1 macrophage aggregation is involved in the formation of induced membranes and osteogenesis and may be facilitated by the presence of spacers.


Bone & Joint Research
Vol. 7, Issue 3 | Pages 252 - 262
1 Mar 2018
Nishida K Matsushita T Takayama K Tanaka T Miyaji N Ibaraki K Araki D Kanzaki N Matsumoto T Kuroda R

Objectives

This study aimed to examine the effects of SRT1720, a potent SIRT1 activator, on osteoarthritis (OA) progression using an experimental OA model.

Methods

Osteoarthritis was surgically induced by destabilization of the medial meniscus in eight-week-old C57BL/6 male mice. SRT1720 was administered intraperitoneally twice a week after surgery. Osteoarthritis progression was evaluated histologically using the Osteoarthritis Research Society International (OARSI) score at four, eight, 12 and 16 weeks. The expression of SIRT1, matrix metalloproteinase 13 (MMP-13), a disintegrin and metalloproteinase with thrombospondin motifs-5 (ADAMTS-5), cleaved caspase-3, PARP p85, and acetylated nuclear factor (NF)-κB p65 in cartilage was examined by immunohistochemistry. Synovitis was also evaluated histologically. Primary mouse epiphyseal chondrocytes were treated with SRT1720 in the presence or absence of interleukin 1 beta (IL-1β), and gene expression changes were examined by real-time polymerase chain reaction (PCR).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 40 - 40
1 Mar 2017
Takayama K Matsumoto T Muratsu H Ishida K Matsushita T Kuroda R
Full Access

Background

Post-operative (postop) lower limb alignment in unicompartmental knee arthroplasty (UKA) has been reported to be an important factor for postop outcomes. Slight under-correction of limb alignment has been recommended to yield a better clinical outcomes than neutral alignment. It is useful if the postop limb alignment can be predicted during surgery, however, little is known about the surgical factors affecting the postop limb alignment in UKA. The purpose of this study was to examine the influence of the medial tibial joint line elevation on postop limb alignment in UKA.

Methods

Seventy-four consecutive medial UKAs were enrolled in this study. All the patients received a conventional fixed bearing UKA. Pre-operative (preop) and postop limb alignment was examined using long leg radiograph and lower limb alignment changes were calculated. Femoral and tibial osteotomy thickness were measured during surgery. Medial tibial joint line change was defined as polyethylene thickness minus tibial osteotomy thickness and sawblade thickness (1.27mm). Positive values indicated a tibial joint line elevation. Medial femoral joint line change was defined as femoral distal component thickness (6.5mm) minus femoral distal osteotomy thickness and sawblade thickness. Positive values indicated a femoral joint line reduction. Medial joint distraction width was also calculated by tibial joint line elevation plus femoral joint line reduction. The correlation of lower limb alignment change with polyethylene insert thickness, the medial tibial joint line elevation, femoral joint line reduction, or joint distraction width were analyzed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 141 - 141
1 Feb 2017
Matsumoto T Takayama K Ishida K Tanaka T Inokuchi T Matsushita T Kuroda R
Full Access

Purpose

Recently, kinematic aligned total knee arthroplasty (TKA) has gained interest for achieving better clinical outcomes over mechanical aligned TKA. The primary goal of kinematic aligned TKA is to position the femoral and tibial components so that the angles and levels of the distal and posterior femoral joint lines and the tibial joint line are each restored to the patient's natural alignment, and not to a neutral limb alignment that is unnatural for most patients. Despite good clinical outcomes reported at short to mid-term follow-up, surgeons should know reasons why this method is useful and safe surgery and carefully assess the long-term outcomes until this new technique is settled as standardized procedure for TKA. The main purpose of the present study was to compare postoperative radiography and clinical scores following kinematic and mechanical aligned TKA.

Methods

Sixty TKAs—30 kinematic and 30 mechanical aligned—were performed in patients with varus-type osteoarthritis using a navigation system. Using postoperative double-leg and single-leg standing long leg radiographs, joint line orientation angle to the floor, conventional mechanical axis (cMA), and true mechanical axis (tMA; line from hip center to the lowest point of calcaneus) were compared between the two groups. One-year after surgeries, range of motion and the patient-derived score of the 2011 Knee Society Score (2011 KSS), which includes four categories: symptoms, patient satisfaction, patient expectations, and functional activities, e.g., walking/standing, standard activities, advanced activities, and discretionary activities, were compared between the two groups


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 24 - 24
1 May 2016
Matsumoto T Shibanuma N Takayama K Sasaki H Ishida K Nakano N Matsushita T Kuroda R Kurosaka M
Full Access

The influence of soft tissue balance in mobile-bearing posterior-stabilized (PS) total knee arthroplasty (TKA) on the patellofemoral (PF) joint was investigated in thirty varus-type osteoarthritis patients. Intraoperative soft tissue balance including joint component gap and varus/valgus ligament balance and the medial/lateral patellar pressure were measured throughout the range of motion after the femoral component placement and the PF joint repair. The lateral patellar pressure, which was significantly higher than the medial side in the flexion arc, showed inverse correlation with the lateral laxity at 60° and 90° of flexion. The lateral patellar pressure at 120° and 135° of flexion also inversely correlated with the postoperative flexion angle. Surgeons should take medial and lateral laxity into account when considering PF joint kinematics influencing postoperative flexion angle in PS TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 53 - 53
1 Jan 2016
Mori S Asada S Inoue S Matsushita T Hashimoto K Akagi M
Full Access

Objective

Tibia vara seen in Japanese patients reportedly influences the tibial component alignment when performing TKA. However, it is unclear whether tibia vara affects the component position and size selection. We therefore determined (1) the amount of medial tibial bow, (2) whether the tibia vara influences the aspect ratio of the tibial resected surface in aligning the tibial component with the tibial shaft axis (TSA), and (3) whether currently available tibial components fit the shapes of resected proximal tibias in terms of aspect ratio.

Material and Methods

The study was performed using CT data from 90 lower limbs in 74 Japanese female patients with primary varus knee OA, scheduled for primary TKAs between January 2010 and March 2012. We measured the tibia vara angle (TVA; the angle between the TSA and the tibial mechanical axis), proximal varus angle (PVA; angle between the TSA and the line connecting the center of the tibial eminence and the center of the proximal 1/3 of the tibia) using three-dimensional preoperative planning software [Fig.1]. Then the mediolateral and middle AP dimensions of the resected surface when the tibial component was set so that its center aligned with the TSA was measured. We determined the correlations of the aspect ratio (the ML dimension divided by the AP dimension) of the resected surface with TVA or PVA and compared the aspect ratios to those of five prosthesis designs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 37 - 37
1 Jan 2016
Hidani K Matsushita T
Full Access

Total knee arthroplasty(TKA) for patients with severe varus deformity has become common operation in Japan because of the rapid aging of the population. Treatment of severe malalignment, instability and bone defects is important. Here we report the clinical results of total knee arthroplasty for 23 knees with severe varus deformity. We defined a severe varus knee femorotibial angle(FTA) as one exceeding 195 degrees. The average observation period was 64 months. Autologous bone graft was performed for 3 knees and augmentation and long tibia stem was used for 3 knees. We used SF-36 for clinical evaluation. Image assessment was based on the standing HKA(Hip-Knee-Ankle)angle, and the Knee Society TKA roentgenographic evaluation and scoring system. The mean SF-36 score improved from 47.6 points to 63.7 points after TKA. The standing mean HKA angle was 204°(range 197° to 215°) before surgery and was corrected to 185°(range 176° to 195°). The post-operative standing HKA angle was classified as HKA>184°, 184°>HKA>177°, HKA<176°. A clear zone appeared in zone1 on tibia APX-ray in 4 knees belonging to the HKA>184° group. Our 23 knees achieved good results, and careful postoperative observation is still necessary especially in the vgarus group.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 29 - 29
1 Jan 2016
Matsumoto T Takayama K Kawakami Y Ishida K Muratsu H Matsuzaki T Uefuji A Nakano N Matsushita T Kuroda R Kurosaka M
Full Access

Purpose

Surgeons sometimes encounter moderate or severe varus deformed osteoarthritic cases in which medial substantial release including semimembranosus is compelled to appropriately balance soft tissues in total knee arthroplasty (TKA). However, medial stability after TKA is important for acquisition of proper knee kinematics to lead to medial pivot motion during knee flexion. The purpose of the present study is to prove the hypothesis that step by step medial release, especially semimembranosus release, reduces medial stability in cruciate-retaining (CR) total knee arthroplasty (TKA).

Methods

Twenty CR TKAs were performed in patients with moderate varus-type osteoarthritis (10° < varus deformity <20°) using the tibia first technique guided by a navigation system (Orthopilot). During the process of medial release, knee kinematics including tibial internal rotation and anterior translation during knee flexion were assessed using the navigation system at 3 points; (1) after anterior cruciate ligament resection (pre-release), (2) medial tibial and femoral osteophyte removal and release of minimum deep layer of medial collateral ligament (minimum release) and (3) release of semimembranosus (semimembranosus release). In addition, the kinematics after all prostheses implantation (semimembranosus release group) were assessed and compared with those assessed in another 20 patients in which only minimum release was performed (minimum release group).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 48 - 48
1 Jan 2016
Takayama K Matsumoto T Muratsu H Nakano N Shibanuma N Tei K Matsushita T Kuroda R Kurosaka M
Full Access

Purpose

The tibia first technique in unicompartmental knee arthroplasty (UKA) may have the advantage that surgeons can obtain a balanced flexion-extension gap. However, changes of the soft tissue tension during UKA has not been elucidated yet. The purpose of this study was to examine the correlation between the soft tissue tension before the femoral osteotomy and after the femoral component in place using the tensor in UKA.

Methods

Thirty UKAs for isolated medial compartmental osteoarthritis or idiopathic osteonecrosis were assessed. The mean age was 71.8±8.5 years old (range: 58–85), and the average coronal plane femorotibial angle (FTA) was 181.2±3.2 degree preoperatively. All the patients received a conventional medial Zimmer Unicompartmental High Flex Knee System (Zimmer Inc, Warsaw, Ind). The actual values of the proximal and posterior femoral osteotomy were calculated by adding the thickness of the bone saw blades to the thickness of the bony cut. Using a UKA tensor which designed to facilitate intra-operative soft tissue tension throughout the range of motion (ROM), the original gap before the femoral osteotomy, the component gap after the femoral osteotomy, and component placement were assessed under 20 lb distraction forces. (Figure 1)


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 78 - 78
1 Jan 2016
Nakano N Matsumoto T Muratsu H Matsushita T Takayama K Kawakami Y Nagai K Kuroda R Kurosaka M
Full Access

Patients planning to undergo total knee arthroplasty (TKA), especially in Asian and Middle Eastern countries, usually expect to be able to perform activities requiring knee flexion such as sitting cross-legged or kneeling with ease after the surgery. Postoperative range of motion (ROM) can be affected by multiple factors such as the patient's gender, age, preoperative ROM, diagnosis, the surgeon's technique, the pre- and post-operative rehabilitation program, and the design of the prosthesis. Among these, the choice of the prosthesis depends on the surgeon's preference. As a result, several trials and studies have been conducted to improve postoperative ROM by modifying prosthesis design. The present study aimed to examine the results of TKA with the NexGen LPS-Flex system (Zimmer, Warsaw, Indiana), which is one of several high-flexion total knee prostheses that were designed to achieve a wide ROM for osteoarthritis in the valgus knee. A total of 27 primary TKAs in 26 osteoarthritis patients with valgus knee deformities (femorotibial angle (FTA) ≤ 170°) were performed using the NexGen LPS-Flex fixed prosthesis between July 2003 and December 2011. The patients included 2 men (7.7%, 2 knees) and 24 women (92.3%, 25 knees) with a mean age of 72.6 years (range, 59 to 83 years) at the time of the surgery. The mean duration of follow-up after surgery was 50.1 months (range, 24 to 126 months). Knee Society Knee Score (KSKS), Knee Society Function Score (KSFS), maximum flexion angle, maximum extension angle, and radiological femorotibial angle (FTA) were evaluated pre- and post-operatively. The mean preoperative KSKS and KSFS were 42.6 points (SD 7.5) and 41.1 points (SD 8.6), respectively, which improved after surgery to 82.2 points (SD 8.2) and 80.9 points (SD 7.6), respectively (P < 0.01). The maximum flexion angle improved from 109.1° (SD 23.1) to 117.3° (SD 12.4) postoperatively, but it did not reach statistical significance (P = 0.097). The preoperative maximum extension angle improved from −9.7° (SD 10.8) to −3.6° (SD 4.9) postoperatively (p < 0.05). The mean radiological FTA was 166.4° (SD 4.2; range: 155° − 170°) preoperatively and 172.4° (SD 2.7; range: 168° − 178°) at the final follow-up, and the difference was statistically significant (P < 0.01). None of the patients had undergone revision surgery by the final follow-up. As a conclusion, the results of the present study showed that the use of NexGen LPS-Flex implant in TKA for knee osteoarthritis with valgus deformity produced a satisfactory improvement in the clinical and radiological outcomes. Further studies on the outcomes of other prosthesis are needed to determine whether the NexGen LPS-Flex implant is advantageous for osteoarthritis patients with valgus knees who undergo TKA, and further large-scale studies with longer term follow-up are necessary to verify our results.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 68 - 68
1 Jul 2014
Harada N Watanabe Y Abe S Sato K Iwai T Yamamoto I Yamada K Yamanaka K Sakai Y Kaneko T Matsushita T
Full Access

Introduction

Mesenchymal stem cells (MSCs) are identified by having the ability to differentiate into various tissues and typically used to generate bone tissue by a process of resembling intramembranous ossification, namely by direct osteoblastic differentiation. However, most bones develop by endochondral ossification, namely via remodeling of hypertrophic cartilaginous templates. To date, reconstruction of bone defects by endochondral ossification using mesenchymal stem cell-derived chondrocytes (MSC-DCs) have not been reported. The purpose of this study was to evaluate the effects of the transplantation of MSC-DCs on bone healing in segmental defects in rat femurs.

Methods

Segmental bone defects (5, 10, 15-millimeter) were produced in the mid-shaft of the femur of the Fisher 344 rats and stabilised with an external fixator. Bone marrow was aspirated from the rat's femur and tibia at 4 weeks before operation. MSCs were isolated and grown in culture and seeded on a Poly dl-lactic-co glycolic acid (PLGA) scaffold. Subsequently, the scaffold was cultured using chondrogenic inducing medium for 21 days. The characteristics of the PLGA scaffold are radiolucent and to be absorbed in about 4 months. The Treatment Group received MSC-DCs, seeded on a PLGA scaffold, locally at the site of the bone defect, and Control Group received scaffold only. The healing processes were monitored radiographically and studied biomechanically and histologically.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 19 - 19
1 Apr 2013
Harada N Watanabe Y Abe S Sato K Yamanaka K Sakai Y Kaneko T Matsushita T
Full Access

Purpose

The purpose of this study was to evaluate the effects of implantation of mesenchymal stem cell derived condrogenic cells (MSC-DC) on bone healing in segmental defects in rat femur.

Methods

Five-millimeter segmental bone defects were produced in the mid-shaft of the femur of Fisher 344 rats and stabilized with external fixator. The Treatment Group received MSC-DC, seeded on a PLGA scaffold, locally at the site of the bone defect, and Control Group received scaffold only. The healing processes were monitored radiographically (Softex), and studied radiographically (Micro-CT) and histologically.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 65 - 65
1 Apr 2013
Watanabe Y Takenaka N Kobayashi M Matsushita T
Full Access

Objective

To investigate the outcomes of patients following the chipping procedures as an alternative to bone grafting in treatment of non-unions after long bone fracture.

Patients

Sixteen patients with femoral or tibial non-union were included. The median follow-up was 24 months.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 83 - 83
1 Apr 2013
Sato K Watanabe Y Abe S Harada N Yamanaka K Sakai Y Kaneko T Matsushita T
Full Access

Introduction

what size of defect is optimal for creating an atrophic nonunion animal model has not been well defined. Our aim in this study was to establish a clinically relevant model of atrophic nonunion in rat femur by creation of a bone defect to research fracture healing and nonunion.

Materials and methods

We used 30 male Fischer 344 rats (aged 10–11 weeks), which were equally divided into six groups. The segmental bone defects to a single femur in each rat were performed by double transverse osteotomy, and different sized defects were created by group for each group (1 mm, 2 mm, 3 mm, 4 mm, 5 mm and 6 mm). The defects were measured and maintained strictly by using an original external fixator. The periosteum for each defect was stripped both proximally and distally. Thereafter, these models were evaluated by radiology and histology. Radiographs were taken at baseline and at intervals of two weeks over a period of 8 weeks. Atrophic nonunion was defined as a lack of continuity and atrophy of both defect ends radiologically and histologically at eight weeks.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 35 - 35
1 Apr 2013
Sato K Watanabe Y Abe S Harada N Yamanaka K Sakai Y Kaneko T Matsushita T
Full Access

Reconstruction of 10mm segmental bone defects in rat by mesenchymal stem cell derived chondrogenic cells (MSC-DC)

Background

Mesenchymal stem cell derived condrogenic cells (MSC-DC) have excellent potential for healing 5 mm bone defect in rat femur.

Purpose

To evaluate the effectiveness of MSC-DC on bone healing in 10 mm segmental bone defects in rat femur.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 30 - 30
1 Apr 2013
Watanabe Y Arai Y Takenaka N Kobayashi M Matsushita T
Full Access

Objective

To determine what factors affect fracture healing with low-intensity pulsed ultrasound (LIPUS) for delayed unions and nonunions.

Patients

A consecutive cohort of 101 delayed unions and 50 nonunions after long bone fractures treated with LIPUS between May 1998 and April 2007.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 36 - 36
1 Apr 2013
Matsui K Miyamoto W Tsuchida Y Takao M Matsushita T
Full Access

Background

Growing of the geriatric population has brought about increase of lower extremity fractures. The purpose of this study was to investigate the occurrence of surgical site infection after the surgery for lower extremity fractures, except proximal femoral fracture, in over eighty years old patients.

Methods

Patients with closed lower extremity fracture which were treated surgically in 2011 were divided into two groups (Group O; the equal or more than 80 years old, Group Y; from 20 to 65 years old), and the incidence of infection and the outcome after its treatment was compared between Group O and Group Y.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 123 - 123
1 Mar 2013
Matsumoto T Muratsu H Kubo S Tei K Sasaki H Matsuzaki T Matsushita T Kurosaka M Kuroda R
Full Access

Backgrounds

In order to permit soft tissue balancing under more physiological conditions during total knee arthroplasties (TKAs), we developed an offset type tensor to obtain soft tissue balancing throughout the range of motion with reduced patella-femoral (PF) and aligned tibiofemoral joints and reported the intra-operative soft tissue balance assessment in cruciate-retaining (CR) and posterior-stabilized (PS) TKA [1, 2]. However, the soft tissue balance in unicompartmental knee arthroplasty (UKA) is unclear. Therefore, we recently developed a new tensor for UKAs that is designed to assist with soft tissue balancing throughout the full range of motion. The first purpose of the present study is to assess joint gap kinematics in UKA. Secondly, we attempted to compare the pattern in UKA with those in CR and PS TKA with the reduced PF joint and femoral component placement, which more closely reproduces post-operative joint alignment.

Methods

Using this tensor, we assessed the intra-operative joint gap measurements of UKAs performed at 0, 10, 30, 45, 60, 90, 120 and 135° of flexion in 20 osteoarthritic patients. In addition, the kinematic pattern of UKA was compared with those of CR and PS TKA that were calculated as medial compartment gap from the previous series of this study.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 257 - 257
1 Mar 2013
Matsuzaki T Matsumoto T Kubo S Muratsu H Matsushita T Oka S Nagai K Kurosaka M Kuroda R
Full Access

Introduction

Appropriate intraoperative soft tissue balancing is recognized to be essential in total knee arthroplasty (TKA). However, it has been rarely reported whether intraoperative soft tissue balance reflects postoperative outcomes. In this study, we therefore assessed the relationship between the intra-operative soft tissue balance measurements and the post-operative stress radiographs at a minimum 1-year follow-up in cruciate-retaining (CR) TKA, and further analyzed the postoperative clinical outcome.

Methods

The subjects were 25 patients diagnosed with osteoarthritis with varus deformity and underwent primary TKA. The mean age at surgery was 72.0 ± 7.5 years (range, 47–84 years). The Surgeries were performed with the tibia first gap technique using CR-TKA (e motion, B. Braun Aesculap) and the image-free navigation system (Orthopilot). We intraoperatively measured varus ligament balance (°, varus angle; VA) and joint component gap (mm, center gap; CG) at 10° and 90° knee flexion guided by the navigation system, with the patella reduced. At a minimum 1-year follow-up, post-operative coronal laxity at extension was assessed by varus and valgus stress radiographs of the knees with 1.5 kgf using a Telos SE arthrometer (Fa Telos) and that at flexion was assessed by epicondylar view radiographs of the knees with a 1.5-kg weight at the ankle. After calculating postoperative VA and CG from measurements of radiographs, measurements and preoperative and postoperative clinical outcome, such as Knee Society Clinical Rating System (Knee score; KSS, Functional score; KSFS) and postoperative knee flexion, were analyzed statistically using linear regression models and Pearson's correlation coefficient.