Vol. 106-B, Issue SUPP_16 | Pages 41 - 41
19 Aug 2024
Cobb J Maslivec A Clarke S Halewood C Wozencroft R
Full Access

A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls.

Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis.

cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain.

This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 6 - 6
17 Apr 2023
Maslivec A Leon D Cobb J
Full Access

Reports of improved functional outcome of Metal on Metal Hip Resurfacing Arthroplasty (mHRA) to Total Hip Replacement needs to be balanced with concerns of metal ion release. By removing cobalt-chrome, cHRA reduces these risks. To the author's knowledge, there is no data available on functional outcomes of cHRA, therefore the aim of the study was to compare the function between cHRA patients and mHRA patients.

24 patients received a unilateral cHRA (H1, Embody) and was compared to 24 age and gender matched patients with a unilateral mHRA (BHR, Smith and Nephew). All patients completed the Oxford Hip Score (OHS)[T2] and underwent gait analysis on an instrumented treadmill before and at a mean of 74wks (+/− 10) for mHRA and 53wks (+/− 2) for cHRA post op. Walking trials started at 4km/h and increased in 0.5km/h increments until a top walking speed (TWS) was achieved. Vertical ground reaction forces (GRF) were recorded along with the symmetry index (SI). Spatiotemporal measures of gait were also recorded. Vertical GRF were captured for the entire normalised stance phase using statistical parametric mapping (SPM; CI = 95%).

The gain in OHS was similar: H1 (25-46), BHR(27-47). TWS increased by 19% with H1 (6.02 – 8.0km/hr), and 20% with BHR (6.02 – 7.37km/hr). SPM of the entire gait cycle illustrated the restoration of symmetry in both groups with no difference in GRF across the stance phase between groups at 5km/hr pre-op and post-op. At faster speeds (6.5km/hr), H1 patients had a mid-support GRF slightly closer to normal compared to BHR. Both groups increased step length similar from pre to post op (H1:0.76 – 0.85cm, BHR:0.77-0.86cm).

In this study, subjective and objective functional outcome measures suggest that short term functional outcomes of ceramic resurfacing is not inferior to metal resurfacing.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 54 - 54
1 Dec 2021
Maslivec A Ng KCG Cobb J
Full Access

Abstract

Objectives

Although hip replacement and resurfacing procedures both aim to restore mobility, improve joint function, and relieve pain, it is unclear how each differ in terms of gait mechanics and if they are affected by varying walking speeds. We compared limb symmetry and ground reaction force (GRF) profiles between bilateral total hip arthroplasty patients (THA), bilateral hip resurfacing arthroplasty patients (HRA), and healthy control participants (CON) during level-treadmill walking at different speeds.

Methods

Bilateral THA and bilateral HRA patients (nTHA = 15; nHRA = 15; postoperative 12–18 months), and age-, mass-, and height-matched CON participants (nCON = 20) underwent gait analysis on an instrumented treadmill. Walking trials started at 4 km/h and increased in 0.5 km/h increments until top walking speed (TWS) was achieved. Gait symmetry index (SI = 0% for symmetry) was assessed between limbs during weight-acceptance, mid-stance and push-off phases of gait; and vertical GRFs were captured for the normalised stance phase using statistical parametric mapping (SPM; CI = 95%).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 6 - 6
1 Nov 2021
Edwards T Maslivec A Ng G Woringer M Wiik A Cobb J
Full Access

Patients may be able to return to higher level activities following hip arthroplasty with modern techniques and prostheses, but the Oxford hip score, the standard PROM used by the NJS exhibits severe skew and kurtosis. The commonest score is 48/48. Most patients score above 40 preventing any discrimination between approaches or prostheses. We therefore sought both subjective and objective metrics which were relevant and valid without skew or high kurtosis in postoperative patients. The Metabolic Equivalent of Task (MET) reports energy usage in kcal/min burnt across a range of activities, condensed into a score of 0–25. A MET over 8 is considered ‘conditioning exercise’ tethered to life expectancy. A 2 point difference in average MET is considered a clinically relevant difference. Walking speed is a simple valid metric tethered to life expectancy, with a 0.1m/sec difference in walking speed equates to a clinically important difference.

Oxford Hip Score (OHS), and the MET were prospectively recorded in 221 primary hip arthroplasty procedures pre-operatively and at 1-year using a web based application. Pre and postoperative Gait analysis was undertaken on a subgroup of 34 patients, in comparison with age and sex matched controls.

Post-operatively, the OHS demonstrated significant skewed distributions with ceiling effects of 41% scoring 48/48. The MET was normally distributed around a mean of 10.3, with a standard deviation of 3.8 and no ceiling effect. Walking speed was normally distributed around a mean of 1.8m/sec, with a standard deviation was 0.15 m/sec

The MET is a simple patient reported score, which is normally distributed in patients following hip arthroplasty, around a mean of 10.3 with a standard deviation of 3.8. This valid activity metric correlates well with fast walking speed. This is also normally distributed with a standard deviation of over 0.1m/sec confirming low kurtosis. These simple measures have face validity: undertaking less active pastimes and being unable to keep up with other walkers are obviously inadvisable. The normal kurtosis of these metrics suggest that they may able to detect clinically relevant differences in outcome which are undetectable with commonly used PROMs. For surgeons developing less invasive approaches or using novel stems, these measures may detect clinically important improvements undetectable by the Oxford Hip Score.