Patient satisfaction after TKR ranges from 75 to 95 percent with 5 to 20 percent of patients who are dissatisfied with their outcome. Noble has shown pain to be the most important factor in patient satisfaction after TKR with others showing patient expectation and increased age to be important. Stability of the flexion gap has been shown by Dennis to be important in wear in the long term, but to our knowledge no study has been done linking stability of the flexion gap to patient satisfaction. 65 patients underwent a computer navigated TKR with a posterior stabilized fixed bearing prosthesis by a single surgeon. Intraoperative measurements were captured of the flexion gap laxity on varus and valgus stress to evaluate stability of the flexion gap. Patients were divided into a stable group with lift off of 3 mm or less and a lax group with lift off of more than 3 mm on either side. No patient in either group had symptoms of clinical instability. This was correlated with patient satisfaction at one year postoperatively as assessed by telephonic interview.Background
Methods