Advertisement for orthosearch.org.uk
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 58 - 58
1 Mar 2013
Drinkwater C Madsen W Brown M
Full Access

Hypothesis

Custom cutting blocks can produce similar alignment compared to computer navigated and conventional total knee arthroplasty (TKA) techniques.

Method

We conducted a retrospective review of 37 patients who underwent TKA by a single surgeon in a teaching hospital setting. Groups were conventional method (10), computer assisted navigation (10), and custom blocks (18). The custom group was further subdivided to CT and MRI based blocks. Post-operative alignment was measured (blinded) using full length weight bearing radiographs at 18 weeks on average. Hospital records were reviewed to determine operative time, transfusion requirements, length of hospital stay, complications and cost.