This was a retrospective analysis of the medium-
to long-term results of 46 TC3 Sigma revision total knee replacements
using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively,
at two years post-operatively, and at a mean follow-up of 8.5 years
(4 to 12). The mean pre-operative International Knee Society (IKS)
clinical score was 42 points (0 to 74), improving to 83.7 (52 to
100) by the final follow-up. The mean IKS score for function improved
from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up.
At the final follow-up 30 knees (65.2%) had an excellent result, seven
(15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor
result. There were two failures, one with anteroposterior instability
and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long
intramedullary stems and cemented femoral and tibial components,
in both septic and aseptic revisions, results in a satisfactory
clinical and radiological outcome, and has a good medium- to long-term
survival rate.
Resurfacing cemented Themis® prosthesis was used in all cases, with a lateral approach associated with a tibial tubercle osteotomy to achieve correct aligment of extensor mechanism. None patient was lost to follow-up.
Treatment of recurrent total hip arthroplasty (THA) dislocation is always a surgical challenge. Numerous treatments have been developed, but until now there is no gold standard. The goal of our study was to evaluate the results of a non-constrained tripolar implant (Novae) in this indication.
Radiological examination was performed numerically with the software Imagika®
362 revision and 920 primary THA were performed with a minimal of 5 years follow-up in the Orthopaedic Department of Amiens University Hospital with modular necks.
Revision surgery was performed six months to seven years after arthroplasty. Arthrodesis was required for pain related or not to implant loosening or talar necrosis. One patient developed a major deviation of the hind foot secondary to progressive loosening. One patient developed infection early. An iliac graft was used to fill the bone defect in eight patients. An anterior plate-screw fixation was used for six patients, crossed screws for one, a tibiotalar nail for one, and an external fixator for one (with infection).