Osteolysis has been reported following ACJ reconstruction with a synthetic graft. We present the first study into its prevalence and pattern, and its effect on patient outcome. Patients who underwent treatment of an unstable ACJ injury using the Surgilig/LockDown implant were identified via our database. Patients were invited to attend a dedicated outpatient clinic for clinical examination, radiographic evaluation, and completion of outcome scoring. Patients who were unable to attend were contacted by telephone. 49 patients were identified. We assessed 21 clinically at a mean of 7 years post-procedure (range 3–11 years). All had radiographic evidence of distal clavicle and coracoid osteolysis. We did not observe progression of osteolysis from the final post-operative radiographs. A further 13 were contacted by phone. The mean Oxford Shoulder Score was 43 (range 31–48) and mean DASH score was 8.5 (range 3–71). The average Patient Global Impression of Change score was 6 (range 2–7). Six patients underwent removal of a prominent screw at a mean of 2 years after surgery; the pattern of osteolysis was no different in this group. All patients had comparable abduction, forward flexion and internal rotation to their uninjured shoulder. We did not observe any relationship between patient demographics, position of implant or etiology and the pattern of osteolysis. Osteolysis of the distal clavicle and/or coracoid is always seen following synthetic reconstruction of the ACJ using this implant, but is non-progressive. Range of shoulder movement is largely unaffected and patient outcomes remain high.
The TruFit® plug is a cylindrical scaffold designed to bridge defects in articular cartilages. It is a porous structure with interconnected pores, which gives it the capability of providing a framework for the ingrowth new tissue and remodelling to articular cartilage and bone. The aim of this study was to assess the radiological incorporation of TruFit® Plugs using MRI. Between December 2007 & August 2009, 22 patients underwent treatment of a chondral or osteochondral lesion using one or more TruFit Plugs. At a minimum of 2 years, 10 patients (12 lesions) were MRI scanned and assessed with a modified MOCART Scoring system by an independent Consultant Musculoskeletal Radiologist. 8 patients were no longer contactable and 4 patients declined MRI as their knee was asymptomatic. 8 of 12 lesions showed congruent articular cartilage cover with a surface of a similar thickness and signal to the surrounding cartilage and reconstitution of the subchondral bone plate. 2 lesions had a thicker congruent articular surface with a similar signal to the surrounding articular cartilage without restoration of the subchondral bone plate. 2 lesions showed no graft incorporation at all and were filled with granulation tissue. Full incorporation of the bony portion of the plug had occurred in only 3 lesions with partial incorporation in 7 lesions. The remaining portion of these 7 lesions looked cystic on MRI. The MRI appearances of the TruFit® Plug at 2 years are encouraging with the majority (83%) showing good restoration of the articular surface with tissue of similar thickness, congruity and signal as the surrounding articular cartilage. However complete incorporation of the TruFit® Plug is rare and cystic change is common. The significance of this cystic change is not clear.
Previous studies have demonstrated the need of accurate reduction of ankle syndesmosis. Measurement of syndesmosis is difficult on plain radiographs. Recently, a difference of 2mm in anterior and posterior measurements at incisura of the inferior tibio-fibular joint on CT has been described as a measure of malreduction (depicted as ‘G’ for ease of description). Our practice changed towards routine post operative bilateral CT following syndesmosis fixation to assess the reduction and identify potential problems at an early stage. The aim of this primarily radiological study was to determine if the use of bilateral cross sectional imaging brings additional benefit above the more conventional practice of unilateral imaging. Between 2007 and 2009, nineteen patients with ankle fractures involving the syndesmosis were included in the study group who had bilateral CT post operatively. The values of ‘G’ and the mean diastasis (MD) were calculated, representing the average measurement between the fibula and the anterior and posterior incisura.Introduction
Method