Eighteen hip fusions were converted to total
hip replacements. A constrained acetabular liner was used in three hips.
Mean follow up was five years (two to 15). Two (11%) hips failed,
requiring revision surgery and two patients (11%) had injury to
the peroneal nerve. Heterotopic ossification developed in seven
(39%) hips, in one case resulting in joint ankylosis. No hips dislocated. Conversion of hip fusion to hip replacement carries an increased
risk of heterotopic ossification and neurological injury. We advise
prophylaxis against heterotropic ossification. When there is concern
about hip stability we suggest that the use of a constrained acetabular
liner is considered. Despite the potential for complications, this procedure
had a high success rate and was effective in restoring hip function.
Infection following total knee arthroplasty is a devastating complication, requiring considerable effort on the part of the surgeon to eradicate the infection and restore joint function. Two-stage revision is the standard of care in the treatment of peri-prosthetic infection, using a temporary antibiotic-impregnated spacer between procedures. However, controversy remains concerning the use of static versus dynamic spacers, as well as the spacer material. The purpose of this study was to evaluate the clinical outcomes and complications of two-stage revision total knee arthroplasty in patients treated with a metal-on-polyethylene articulating spacer, as compared to those treated with a static antibiotic-impregnated cement spacer at the same centre. Twenty-seven knees in patients with a mean age of 65 years (range, 40 to 80 years) were treated with two-stage revision of an infected total knee arthroplasty using a metal-on-polyethylene dynamic prosthetic spacer fixed with antibiotic-impregnated cement. Clinical outcomes were evaluated using maximum active knee range of motion, as well as modified Knee Society knee scores and incidence of re-infection at a minimum one-year follow-up. The results were compared to those achieved at similar follow-up in 10 patients treated with a static cement spacer. Demographic profile as measured by age and gender, and pre-operative Knee Society scores and range of motion were similar between the two groups.Purpose
Method