Vol. 94-B, Issue SUPP_XXV | Pages 46 - 46
1 Jun 2012
Jenny J Schoenahl J Louis P Diesinger Y
Full Access

INTRODUCTION

Computer-aided systems have been developed recently in order to improve the precision of implantation of a total knee replacement (TKR). Several authors demonstrated that the accuracy of implantation of TKR was higher with the help of a navigation system in comparison to the conventional, manual technique. Theoretically, the clinical results and the survival rates should be improved. Our team was one of the first all over the world which decided to use routinely a navigation system for TKR.

Prostheses designed with a mobile bearing polyethylene component allow an increased congruence between femoral and tibial gliding surface, and should decrease the risk of long-term polyethylene wear. We designed a prosthetic system with one of the highest congruence on the current market. These prostheses might be technically more demanding than more conventional designs, and involve specific complications like bearing luxation. Navigation systems might be helpful in this was as well.

In the present study, we wanted to test clinically the theoretic advantages of these three specific points of our system (navigated implantation, mobile bearing and increased congruence) with a five-year clinical and radiological follow-up.

MATERIAL AND METHODS

128 patients were operated on at our Department with this TKR system between 2000, and were contacted for a five-year clinical and radiological follow-up. The clinical and functional results were evaluated according to the Knee Society Scoring System (KSS). The subjective results were analyzed with the Oxford Knee Score. The accuracy of implantation was assessed on post-operative long leg antero-posterior and lateral X-rays. The survival rate after 5 years was calculated according to the Kaplan-Meier technique.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 47 - 47
1 Jun 2012
Jenny J Saussac F Louis P Diesinger Y
Full Access

INTRODUCTION

Computer-aided systems have been developed recently in order to improve the precision of implantation of a total knee replacement (TKR). Several authors demonstrated that the accuracy of implantation of an unicompartmental knee replacement (UKR) was also improved.

Minimal invasive techniques have been developed to decrease the surgical trauma related to the prosthesis implantation. The benefits of minimal-incision surgery might include less surgical dissection, less blood loss and pain, an earlier return to function, a smaller scar, and subsequently lower costs. However, there might be a concern about the potential of minimal invasive techniques for a loss of accuracy. Navigation might help to compensate for these difficulties.

Mobile bearing prostheses have been developed to decrease the risk of polyethylene wear. The benefits might be a better survival and less bone loss during revisions. However, these prosthesis are technically more demanding, and involve the specific risk of bearing luxation. Again, navigation might help to compensate for these difficulties.

MATERIAL AND METHODS

We wanted to combine the theoretical advantages of the three different techniques by developing a navigated, minimal invasive, mobile bearing unicompartmental knee prosthesis. 160 patients have been operated on at our institution with this system. The 81 patients with more than 2 year follow-up have been re-examined. Complications have been recorded. The clinical results have been analyzed according to the Knee Society Scoring System. The subjective results have been analyzed with the Oxford Knee Questionnaire. The accuracy of implantation has been analyzed on post-operative antero-posterior and lateral long leg X-rays. The 2-year survival rate has been calculated.