The cementless Oxford unicompartmental knee replacement
has been demonstrated to have superior fixation on radiographs and
a similar early complication rate compared with the cemented version.
However, a small number of cases have come to our attention where,
after an apparently successful procedure, the tibial component subsides into
a valgus position with an increased posterior slope, before becoming
well-fixed. We present the clinical and radiological findings of
these six patients and describe their natural history and the likely
causes. Two underwent revision in the early post-operative period,
and in four the implant stabilised and became well-fixed radiologically with
a good functional outcome. This situation appears to be avoidable by minor modifications
to the operative technique, and it appears that it can be treated
conservatively in most patients. Cite this article:
New developments in osteotomy techniques and methods of fixation have caused a revival of interest of osteotomies around the knee. The current consensus on the indications, patient selection and the factors influencing the outcome after high tibial osteotomy is presented. This paper highlights recent research aimed at joint pressure redistribution, fixation stability and bone healing that has led to improved surgical techniques and a decrease of post-operative time to full weight-bearing.
High Tibial Osteotomy (HTO) is an established treatment for unicompartmental osteoarthritis of the knee with malalignment. The classic procedure for correcting varus deformity is the lateral closed wedge osteotomy of the tibia with osteotomy of the fibula. The disadvantages of this technique are well known. Open wedge osteotomy from the medial sideeliminates the risk of compartment syndrome and peroneal nerve injuries. A new fixation device (TomoFix(tm)) with an adapted surgical technique allows stable fixation of the osteotomy without the need to fill the osteotomy gap with bone grafts. In a prospective study, 92 consecutive cases were treated with this procedure. Bony healing with remodelling of the medial and posterior cortical bone was observed. Full weight-bearing was possible ten weeks after surgery. There were no implant failures. Complications included one delayed union, two revarisations and one deep infection. Keywords: High Tibial Osteotomy (HTO), openwedge osteotomy, TomoFix(tm) plate, medial osteoarthritis, varus knee
We assessed proprioception in the knee using the angle reproduction test in 20 healthy volunteers, ten patients with acute anterior instability and 20 patients with chronic anterior instability after reconstruction of the anterior cruciate ligament (ACL). In addition, the Lysholm-knee score, ligament laxity and patient satisfaction were determined. Acute trauma causes extensive damage to proprioception which is not restored by rehabilitation alone. Three months after operation, there remained a slight decrease in proprioception compared with the preoperative recordings, but six months after reconstruction, restoration of proprioception was seen near full extension and full flexion. In the mid-range position, proprioception was not restored. At follow-up, 3.7 ± 0.3 years after reconstruction, there was further improvement of proprioception in the mid-range position. There was no difference between open and arthroscopic techniques. The highest correlation was found between proprioception and patient satisfaction. After reconstruction of the ACL reduced proprioception may explain the poor functional outcome in some patients, despite restoration of mechanical stability.