Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 386 - 393
1 Mar 2022
Neufeld ME Liechti EF Soto F Linke P Busch S Gehrke T Citak M

Aims

The outcome of repeat septic revision after a failed one-stage exchange for periprosthetic joint infection (PJI) in total knee arthroplasty (TKA) remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat septic revision after a failed one-stage exchange, and to determine whether the Musculoskeletal Infection Society (MSIS) stage is associated with subsequent infection-related failure.

Methods

We retrospectively reviewed all repeat septic revision TKAs which were undertaken after a failed one-stage exchange between 2004 and 2017. A total of 33 repeat septic revisions (29 one-stage and four two-stage) met the inclusion criteria. The mean follow-up from repeat septic revision was 68.2 months (8.0 months to 16.1 years). The proportion of patients who had a subsequent infection-related failure and all-cause revision was reported and Kaplan-Meier survival for these endpoints was determined. Patients were categorized according to the MSIS staging system, and the association with subsequent infection was analyzed.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 27 - 33
1 Jan 2022
Liechti EF Neufeld ME Soto F Linke P Busch S Gehrke T Citak M

Aims

One-stage exchange for periprosthetic joint infection (PJI) in total hip arthroplasty (THA) is gaining popularity. The outcome for a repeat one-stage revision THA after a failed one-stage exchange for infection remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat one-stage exchange, and to investigate the association between the Musculoskeletal Infection Society (MSIS) staging system and further infection-related failure.

Methods

We retrospectively reviewed all repeat one-stage revision THAs performed after failed one-stage exchange THA for infection between January 2008 and December 2016. The final cohort included 32 patients. The mean follow-up after repeat one-stage exchange was 5.3 years (1.2 to 13.0). The patients with a further infection-related failure and/or all-cause revision were reported, and Kaplan-Meier survival for these endpoints determined. Patients were categorized according to the MSIS system, and its association with further infection was analyzed.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 27 - 27
1 Nov 2021
Gehrke T Althaus L Linke P Salber J Krenn V Citak M
Full Access

Arthrofibrosis is a relatively frequent complication after total knee arthroplasty. Although stiffness after total hip arthroplasty (THA), because of formation of heterotopic ossification or other causes, is not uncommon, to the authors’ best knowledge, arthrofibrosis after THA has not been described. The aim of this study is to describe the arthrofibrosis of the hip after primary total hip arthroplasty using an established clinical and histological classification of arthrofibrosis.

We retrospectively examined all patients who were histologically confirmed to have arthrofibrosis after primary THA during revision surgery by examination of tissue samples in our clinic. Arthrofibrosis was diagnosed according to the histopathological SLIM-consensus classification, which defines seven different SLIM types of the periimplant synovial membrane. The SLIM type V determines the diagnosis of endoprosthesis-associated arthrofibrosis.

The study population consists of 66 patients who were revised due to arthrofibrosis after primary THA. All patients had a limitation in range of motion prior to revision with a mean flexion of 90° (range from 40 to 125), mean internal rotation of 10° (range from 0 to 40) and mean external rotation of 20° (range from 0 to 50). All patients had histological SLIM type V arthrofibrosis, corresponding to endoprosthesis-associated arthrofibrosis. Histological examination revealed that seven patients (10.6%) had particle-induced and 59 patients (89.4%) had non-particle-induced arthrofibrosis.

This is the first decription of endoprosthetic-associated arthrofibrosis after primary THA on the basis of a well-established histological classification. Our study results could enable new therapeutic and diagnostic opportunities in patients with such an arthrofibrosis. Surgeons should keep arthrofibrosis as a possible cause for stiffness and pain after primary total hip arthroplasty in mind. Level of evidence Diagnostic study, Level of Evidence IV

Thorsten Gehrke and Lara Althaus contributed equally to the writing of this manuscript.