Advertisement for orthosearch.org.uk
Results 1 - 20 of 67
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 759 - 759
1 Jul 2024
Bae K Lee B Kim J Bin S Lee J Kim D Jeon T


Aims

The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral.

Methods

The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype.


Bone & Joint Open
Vol. 4, Issue 9 | Pages 676 - 681
5 Sep 2023
Tabu I Goh EL Appelbe D Parsons N Lekamwasam S Lee J Amphansap T Pandey D Costa M

Aims

The aim of this study was to describe the current pathways of care for patients with a fracture of the hip in five low- and middle-income countries (LMIC) in South Asia (Nepal and Sri Lanka) and Southeast Asia (Malaysia, Thailand, and the Philippines).

Methods

The World Health Organization Service Availability and Readiness Assessment tool was used to collect data on the care of hip fractures in Malaysia, Thailand, the Philippines, Sri Lanka, and Nepal. Respondents were asked to provide details about the current pathway of care for patients with hip fracture, including pre-hospital transport, time to admission, time to surgery, and time to weightbearing, along with healthcare professionals involved at different stages of care, information on discharge, and patient follow-up.


Bone & Joint Research
Vol. 12, Issue 8 | Pages 497 - 503
16 Aug 2023
Lee J Koh Y Kim PS Park J Kang K

Aims

Focal knee arthroplasty is an attractive alternative to knee arthroplasty for young patients because it allows preservation of a large amount of bone for potential revisions. However, the mechanical behaviour of cartilage has not yet been investigated because it is challenging to evaluate in vivo contact areas, pressure, and deformations from metal implants. Therefore, this study aimed to determine the contact pressure in the tibiofemoral joint with a focal knee arthroplasty using a finite element model.

Methods

The mechanical behaviour of the cartilage surrounding a metal implant was evaluated using finite element analysis. We modelled focal knee arthroplasty with placement flush, 0.5 mm deep, or protruding 0.5 mm with regard to the level of the surrounding cartilage. We compared contact stress and pressure for bone, implant, and cartilage under static loading conditions.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 663 - 667
1 Jun 2023
Youn S Rhee SM Cho S Kim C Lee J Rhee YG

Aims

The aim of this study was to investigate the outcomes of arthroscopic decompression of calcific tendinitis performed without repairing the rotator cuff defect.

Methods

A total of 99 patients who underwent treatment between December 2013 and August 2019 were retrospectively reviewed. Visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) scores were reviewed pre- and postoperatively according to the location, size, physical characteristics, and radiological features of the calcific deposits. Additionally, the influence of any residual calcific deposits shown on postoperative radiographs was explored. The healing rate of the unrepaired cuff defect was determined by reviewing the 29 patients who had follow-up MRIs.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 45 - 45
1 Dec 2022
Lung T Lee J Widdifield J Croxford R Larouche J Ravi B Paterson M Finkelstein J Cherry A
Full Access

The primary objective is to compare revision rates for lumbar disc replacement (LDR) and fusion at the same or adjacent levels in Ontario, Canada. The secondary objectives include acute complications during hospitalization and in 30 days, and length of hospital stay.

A population-based cohort study was conducted using health administrative databases including patients undergoing LDR or single level fusion between October 2005 to March 2018. Patients receiving LDR or fusion were identified using physician claims recorded in the Ontario Health Insurance Program database. Additional details of surgical procedure were obtained from the Canadian Institute for Health Information hospital discharge abstract. Primary outcome measured was presence of revision surgery in the lumbar spine defined as operation greater than 30 days from index procedure. Secondary outcomes were immediate/ acute complications within the first 30 days of index operation.

A total of 42,024 patients were included. Mean follow up in the LDR and fusion groups were 2943 and 2301 days, respectively. The rates of revision surgery at the same or adjacent levels were 4.7% in the LDR group and 11.1% in the fusion group (P=.003). Multivariate analysis identified risk factors for revision surgery as being female, hypertension, and lower surgeon volume. More patients in the fusion group had dural tears (p<.001), while the LDR group had more “other” complications (p=.037). The LDR group had a longer mean hospital stay (p=.018).

In this study population, the LDR group had lower rates of revision compared to the fusion group. Caution is needed in concluding its significance due to lack of clinical variables and possible differences in indications between LDR and posterior decompression and fusion.


Bone & Joint Research
Vol. 11, Issue 7 | Pages 494 - 502
20 Jul 2022
Kwon HM Lee J Koh Y Park KK Kang K

Aims

A functional anterior cruciate ligament (ACL) or posterior cruciate ligament (PCL) has been assumed to be required for patients undergoing unicompartmental knee arthroplasty (UKA). However, this assumption has not been thoroughly tested. Therefore, this study aimed to assess the biomechanical effects exerted by cruciate ligament-deficient knees with medial UKAs regarding different posterior tibial slopes.

Methods

ACL- or PCL-deficient models with posterior tibial slopes of 1°, 3°, 5°, 7°, and 9° were developed and compared to intact models. The kinematics and contact stresses on the tibiofemoral joint were evaluated under gait cycle loading conditions.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 62 - 62
1 Mar 2021
Lee J Perera J Trottier ER Tsoi K Hopyan S
Full Access

Paediatric bone sarcomas around the knee are often amenable to either endoprosthetic reconstruction or rotationplasty. Cosmesis and durability dramatically distinguish these two options, although patient-reported functional satisfaction has been similar among survivors. However, the impact on oncological and surgical outcomes for these approaches has not been directly compared.

We retrospectively reviewed all wide resections for bone sarcoma of the distal femur or proximal tibia that were reconstructed either with an endoprosthesis or by rotationplasty at our institution between June 2004 and December 2014 with a minimum two year follow-up. Pertinent demographic information, surgical and oncological outcomes were reviewed. Survival analysis was performed using the Kaplan-Meier method with statistical significance set at p<0.05.

Thirty eight patients with primary sarcomas around the knee underwent wide resection and either endoprosthetic reconstruction (n=19) or rotationplasty (n=19). Groups were comparable in terms of demographic parameters and systemic tumour burden at presentation. We found that selection of endoprosthetic reconstruction versus rotationplasty did not impact overall survival for the entire patient cohort but was significant in subgroup analysis. Two-year overall survival was 86.7% and 85.6% in the endoprosthesis and rotationplasty groups, respectively (p=0.33). When only patients with greater than 90% chemotherapy-induced necrosis were considered, overall survival was significantly better in the rotationplasty versus endoprosthesis groups (100% vs. 72.9% at two years, p=0.013). Similarly, while event-free survival was not affected by reconstruction method (60.2% vs. 73.3% at two years for endoprosthesis vs rotationplasty, p=0.27), there was a trend towards lower local recurrence in rotationplasty patients (p=0.07). When surgical outcomes were considered, a higher complication rate was seen in patients that received an endoprosthesis compared to those who underwent rotationplasty. Including all reasons for re-operation, 78.9% (n=15) of the endoprosthesis patients required a minimum of one additional surgery compared with only 26.3% (n=5) among rotationplasty patients (p=0.003). The most common reasons for re-operation in endoprosthesis patients were wound breakdown/infection (n=6), limb length discrepancy (n=6) and periprosthetic fracture (n=2). Excluding limb length equalisation procedures, the average time to re-operation in this patient population was 5.6 months (range 1 week to 23 months). Similarly, the most common reason for a secondary procedure in rotationplasty patients was wound breakdown/infection, although only two patients experienced this complication. Average time to re-operation in this group was 23.8 months (range 5 to 49 months).

Endoprosthetic reconstruction and rotationplasty are both viable limb-salvage options following wide resection of high-grade bony sarcomas located around the knee in the paediatric population. Endoprosthetic reconstruction is associated with a higher complication rate and may negatively impact local recurrence. Study of a larger number of patients is needed to determine whether the reconstructive choice affects survival.


Bone & Joint Research
Vol. 9, Issue 9 | Pages 593 - 600
1 Sep 2020
Lee J Koh Y Kim PS Kang KW Kwak YH Kang K

Aims

Unicompartmental knee arthroplasty (UKA) has become a popular method of treating knee localized osteoarthritis (OA). Additionally, the posterior cruciate ligament (PCL) is essential to maintaining the physiological kinematics and functions of the knee joint. Considering these factors, the purpose of this study was to investigate the biomechanical effects on PCL-deficient knees in medial UKA.

Methods

Computational simulations of five subject-specific models were performed for intact and PCL-deficient UKA with tibial slopes. Anteroposterior (AP) kinematics and contact stresses of the patellofemoral (PF) joint and the articular cartilage were evaluated under the deep-knee-bend condition.


Aims

Mobile-bearing unicompartmental knee arthroplasty (UKA) with a flat tibial plateau has not performed well in the lateral compartment, leading to a high rate of dislocation. For this reason, the Domed Lateral UKA with a biconcave bearing was developed. However, medial and lateral tibial plateaus have asymmetric anatomical geometries, with a slightly dished medial and a convex lateral plateau. Therefore, the aim of this study was to evaluate the extent at which the normal knee kinematics were restored with different tibial insert designs using computational simulation.

Methods

We developed three different tibial inserts having flat, conforming, and anatomy-mimetic superior surfaces, whereas the inferior surface in all was designed to be concave to prevent dislocation. Kinematics from four male subjects and one female subject were compared under deep knee bend activity.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 76 - 76
1 Jul 2020
Alaqeel M Crapser A Tat J Lee-Howes J Schupbach J Tamimi I Martineau PA
Full Access

Anterior cruciate ligament (ACL) injuries are frequent among athletes and a leading cause of time away from competition. Stability of the knee involves the ACL for limiting anterior tibial translation and the ALL (anterolateral ligament) to restrain internal rotation of the tibia. Present indications for treatment with a combined ACL-ALL reconstruction remain unclear and mostly subjective. We mathematically modeled the tibial plateau geometry to try and identify patients at risk of ACL injury, and develop an objective trigger point for the decision to proceed with additional surgery to optimize rotational stability in these higher risk patients. We hypothesized that an increased convexity and steepness of the posterior aspect of the lateral plateau would subject knees to higher rotational torques leading to potentially a higher risk of ACL injury.

The study design was a case-control study involving ACL reconstruction cases (n=68) and matched controls (n=68) between 2008–2015 at our institution. We used a two-dimensional approach, evaluating sagittal MRI images of the knee to model the posterior convexity of the lateral tibial plateau. Points were selected along the articular surface, and a least-squares regression was used to curve-fit a power function (y = a xn). In the equation, larger coefficient a and n represented steeper slopes. The cases and controls were compared using a Mann-Whitney-U test, and the statistical significance was set at α < 0.05. A subgroup analysis for females and males was also performed for the curve-fit coefficients.

We observed a significant difference in the tibial surface geometry between our ACL reconstruction cases and matched controls (Figure 1). The modeled power equation for our ACL cases had larger coefficients compared to controls for all groups. For all pooled subjects, coefficient a (ACL recon cases = 0.90 vs controls = 0.68, p < 0.0001) and coefficient n (ACL recon cases = 0.34 vs controls = 0.30, p = 0.07) (Table 1). For the statistically significant coefficient a, we found it had a sensitivity of 78.9% and specificity of 77.5% for the statistically significant coefficient a, we found it had a sensitivity of 78.9% and specificity of 77.5% for predicting injury, using a cut off coefficient of a = 0.78. The odds ratio was 12.6 [5.5 – 29].

The posterolateral cartilaginous slope of the tibial plateau was mathematically modeled in patients with ACL injury. Patients with ACL injury demonstrated abnormally steep and fast slopes compared to controls that may play predispose to ACL injury by increasing anterior translation forces and internal rotation torques sustained by their knee joint. A steeper slope may also explain high-grade pivot shifts on physical exam that are thought to be a relative indication for adding an associated ALL reconstruction. Our findings are promising for adding more objectivity to surgical decision-making, especially with identifying high-risk patients that may be candidates for combined ACL-ALL reconstructions.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 125 - 125
1 Jul 2020
Chen T Camp M Tchoukanov A Narayanan U Lee J
Full Access

Technology within medicine has great potential to bring about more accessible, efficient, and a higher quality delivery of care. Paediatric supracondylar fractures are the most common elbow fracture in children and at our institution often have high rates of unnecessary long term clinical follow-up, leading to an inefficient use of healthcare and patient resources. This study aims to evaluate patient and clinical factors that significantly predict necessity for further clinical visits following closed reduction and percutaneous pinning.

A total of 246 children who underwent closed reduction and percutaneous pinning following supracondylar humerus fractures were prospectively enrolled over a two year period. Patient demographics, perioperative course, goniometric measurements, functional outcome measures, clinical assessment and decision making for further follow up were assessed. Categorical and continuous variables were analyzed and screened for significance via bivariate regression. Significant covariates were used to develop a predictive model through multivariate logistical regression. A probability cut-off was determined on the Receiver Operator Characteristic (ROC) curve using the Youden index to maximize sensitivity and specificity. The regression model performance was then prospectively tested against 22 patients in a blind comparison to evaluate accuracy.

246 paediatrics patients were collected, with 29 cases requiring further follow up past the three month visit. Significant predictive factors for follow up were residual nerve palsy (p < 0 .001) and maximum active flexion angle of injured elbow (p < 0 .001). Insignificant factors included other goniometric measures, subjective evaluations, and functional outcomes scores. The probability of requiring further clinical follow up at the 3 month post-op point can be estimated with the equation: logit(follow-up) = 11.319 + 5.518(nerve palsy) − 0.108(maximum active flexion). Goodness of fit of the model was verified with Nagelkerke R2 = 0.574 and Hosmer & Lemeshow chi-square (p = 0.739). Area Under Curve of the ROC curve was C = 0.919 (SE = 0.035, 95% CI 0.850 – 0.988). Using Youden's Index, a cut-off for probability of follow up was set at 0.094 with the overall sensitivity and specificity maximized to 86.2% and 88% respectively. Using this model and cohort, 194 three month clinic visits would have been deemed medically unnecessary. Preliminary blind prospective testing against the 22 patient cohort demonstrates a model sensitivity and specificity at 100% and 75% respectively, correctly deeming 15 visits unnecessary.

Virtual clinics and automated clinical decision making can improve healthcare inefficiencies, unclog clinic wait times, and ultimately enhance quality of care delivery. Our regression model is highly accurate in determining medical necessity for physician examination at the three month visit following supracondylar fracture closed reduction and percutaneous pinning. When applied correctly, there is potential for significant reductions in health care expenditures and in the economic burden on patient families by removing unnecessary visits. In light of positive patient and family receptiveness toward technology, our promising findings and predictive model may pave the way for remote health care delivery, virtual clinics, and automated clinical decision making.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 126 - 126
1 Jul 2020
Chen T Lee J Tchoukanov A Narayanan U Camp M
Full Access

Paediatric supracondylar fractures are the most common elbow fracture in children, and is associated with an 11% incidence of neurologic injury. The goal of this study is to investigate the natural history and outcome of motor nerve recovery following closed reduction and percutaneous pinning of this injury.

A total of 246 children who underwent closed reduction and percutaneous pinning following supracondylar humerus fractures were prospectively enrolled over a two year period. Patient demographics (age, weight), Gartland fracture classification, and associated traumatic neurologic injury were collected and analyzed with descriptive statistics. Patients with neurologic palsies were separated based on nerve injury distribution, and followed long term to monitor for neurologic recovery at set time points for follow up.

Of the 246 patient cohort, 46 patients (18.6%) sustained a motor nerve palsy (Group 1) and 200 patients (82.4%) did not (Group 2) following elbow injury. Forty three cases involved one nerve palsy, and three cases involved two nerve palsies. No differences were found between patient age (Group 1 – 6.6 years old, Group 2 – 6.2 years old, p = 0.11) or weight (Group 1 – 24.3kg, Group 2 – 24.5kg, p = 0.44). A significantly higher proportion of Gartland type III and IV injuries were found in those with nerve palsies (Group 1 – 93.5%, Group 2 – 59%, p < 0 .001). Thirty four Anterior Interosseous Nerve (AIN) palsies were observed, of which 22 (64.7%) made a full recovery by three month. Refractory AIN injuries requiring longer than three month recovered on average 6.8 months post injury. Ten Posterior Interosseous Nerve (PIN) palsies occurred, of which four (40%) made full recovery at three month. Refractory PIN injuries requiring longer than three month recovered on average 8.4 months post injury. Six ulnar nerve motor palsies occurred, of which zero (0%) made full recovery at three month. Ulnar nerve injuries recovered on average 5.8 months post injury.

Neurologic injury occurs significantly higher in Gartland type III and IV paediatric supracondylar fractures. AIN palsies remain the most common, with an expected 65% chance of full recovery by three month. 40% of all PIN palsies are expected to fully recover by three month. Ulnar motor nerve palsies were slowest to recover at 0% by the three month mark, and had an average recovery time of approximately 5.8 months. Our study findings provide further evidence for setting clinical and parental expectations following neurologic injury in paediatric supracondylar elbow fractures.


Bone & Joint Research
Vol. 8, Issue 12 | Pages 593 - 600
1 Dec 2019
Koh Y Lee J Lee H Kim H Chung H Kang K

Aims

Commonly performed unicompartmental knee arthroplasty (UKA) is not designed for the lateral compartment. Additionally, the anatomical medial and lateral tibial plateaus have asymmetrical geometries, with a slightly dished medial plateau and a convex lateral plateau. Therefore, this study aims to investigate the native knee kinematics with respect to the tibial insert design corresponding to the lateral femoral component.

Methods

Subject-specific finite element models were developed with tibiofemoral (TF) and patellofemoral joints for one female and four male subjects. Three different TF conformity designs were applied. Flat, convex, and conforming tibial insert designs were applied to the identical femoral component. A deep knee bend was considered as the loading condition, and the kinematic preservation in the native knee was investigated.


Bone & Joint Research
Vol. 8, Issue 11 | Pages 563 - 569
1 Nov 2019
Koh Y Lee J Lee H Kim H Kang K

Objectives

Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty with isolated medial or lateral compartment osteoarthritis. However, polyethylene wear can significantly reduce the lifespan of UKA. Different bearing designs and materials for UKA have been developed to change the rate of polyethylene wear. Therefore, the objective of this study is to investigate the effect of insert conformity and material on the predicted wear in mobile-bearing UKA using a previously developed computational wear method.

Methods

Two different designs were tested with the same femoral component under identical kinematic input: anatomy mimetic design (AMD) and conforming design inserts with different conformity levels. The insert materials were standard or crosslinked ultra-high-molecular-weight polyethylene (UHMWPE). We evaluated the contact pressure, contact area, wear rate, wear depth, and volumetric wear under gait cycle loading conditions.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_10 | Pages 38 - 38
1 Oct 2019
Barrett-Lee J Harker R
Full Access

Background

NICE guidance suggests that caudal epidural injections of steroid and local anaesthetic may be considered for acute and severe sciatica, however studies have demonstrated limited long-term benefit and impact on future surgery. This study aimed to investigate the use of caudal epidural injections in a district general hospital setting and the rate of subsequent operation.

Methods

All patients undergoing caudal epidural injection between 1st January and 30th June 2015 were included. Records were reviewed to obtain diagnosis, pre- and post-epidural clinical findings, prior interventions, and subsequent operations.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 123 - 123
1 Nov 2018
Moon J Jung Y Lee J
Full Access

Suture anchor have been used in surgical procedure of tendon or ligament repair. Recently, there has been developed an all suture anchor (soft anchor) which can be used even when the insertion area is narrow. But, the stability of soft anchors due to narrow zone has not been elucidated. This purpose of this study was to investigate stability of soft anchors with respect to their fixation intervals. Polyurethane foams with two different bone densities (10 pcf; 0.16g / cm³, 20 pcf; 0.32g / cm³) were used. All suture anchors and conventional suture anchors were fixed at 10mm, 5mm, and 2.5mm intervals. The failure load was measured using a mechanical testing machine. The average load to failure of conventional suture anchor were 200.4N, 200.2N, 184.7N in the 10mm, 5mm and 2.5mm interval with 10pcf foam bones and 200.4 N, 200.2 N and 184.7 N with the 20 pcf foam bone respectively. Average load to failure load of soft anchor was 97.3N, 93.9N and 76.9N with 10pcf foam bones and 200.4 N, 200.2 N and 184.7 N with 20 pcf foam bone. Suture screw spacing and bone density are important factors in anchor pullout strength. In osteoporotic bone density, insertion of the suture screw interval of 5 mm might be necessary.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 37 - 37
1 Aug 2018
Baek S Lee J Lee YS Kim S
Full Access

We evaluated (1) wear rate, (2) prevalence and volume of osteolysis using 3D-CT scan, (3) other bearing-related complications, (4) HHS and survivorship free from revision at 15 years after THA using first-generation XLPE (1G XLPE).

One-hundred sixty THAs were evaluated regarding bearing-related complication, HHS and survivorship. Among them, 112 hips underwent 3D-CT to analyze wear rate and osteolysis. All THAs were performed by single surgeon using cup of identical design, a 28-mm metal head and 1G XLPE (10 Mrad). Average age were 57 years and mean follow-up was 15.2 years. 3D-CT scan was performed at average of 13.0 years. Clinical evaluation included HHS and radiographic analysis was performed regarding stem alignment, cup anteversion and inclination angle, component stability, wear rate and osteolysis. Wear was measured using digital software. The prevalence and volume of osteolysis were also evaluated. Complications included XLPE dissociation/rim fracture, dislocation, periprosthetic fracture, infection, HO and any revision. Survivorship free from revision at 15 years was estimated.

Average inclination and anteversion angle of cups were 40.7° and 20.6°. Mean stem alignment was 0.1° valgus. Average bedding-in and annual wear rate wear rate was 0.085 mm and 0.025 mm/yr. Eleven hips (10%) demonstrated osteolysis; pelvic osteolysis with average volume of 1.4 cm3 in six and femoral osteolysis with mean size of 0.4 cm2 in seven hips. Of 160 THAs, 5 hips (3%) dislocated. Overall, bearing-related complications occurred in 16 hips (10%). Other complications included postoperative periprosthetic fracture in 4 (3%), infection and HO in 3 hips, respectively. No hip demonstrated loosening, XLPE rim fracture/dissociation. Seven THAs (4%) were revised; recurrent dislocation in 5 and periprosthetic joint infection in 2 hips. Average HHS at last follow-up improved from 47.7 preoperatively to 91.2 points (p<0.001). Estimated survivorship free from revision at 15 years was 95.6 %.

THA using 1G XLPE demonstrated low wear rate as well as low incidence of osteolysis at average follow-up of fifteen years. Longer-term studies will be necessary to determine if XLPE will continue to demonstrate this improved osteolysis characteristics.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 17 - 17
1 Apr 2018
Lee J
Full Access

Purpose

The purpose of this study is to report the results of the first 1000 cases hip arthroplasty using the Bencox® hip stem, the first hip prosthesis developed and manufactured in Korea.

Material & Method

This study reviewed 1000 cases retrospectively who underwent arthroplasty using Bencox® hip system. The Bencox® hip stem is the first hip prosthesis developed and manufactured in Korea. This stem have a double-tapered, wedge shape figure with a rectangular-shaped cross-section and specially designed neck shape, which is design to achieve normal stress pattern of the proximal femur and to increase initial stability and to increase range of motion. Surface is treated with MAO (Micro Arc Oxidation) coating.

From the first arthroplasty with this system in September 2006, sequentially 1000 arthroplasties were performed by single surgeon until the July 2014. This material included 439 men and 561 female. Average age of patients was 65 year old. Follow up period was average 72.1 month (minimum 34 months to maximum 120 months). 1000 cases consisted of 569 hips in patients with femoral neck or intertrochanteric fracture or subtrochanteric fracture (fracture group), 155 hips in osteoarthritis, 192 hips in patients with osteonecrosis of the femoral head (arthritis group), 84 hips in revision surgery (revision group). Revision cases consisted of 58 hips with aseptic loosening and 26 hips with loosening due to infection sequelae. They were underwent hip arthroplasty using a Bencox® hip stem in combination with Bencox® bipolar cup and Bencox®acetabular cup. Patients in the fracture group usually underwent bipolar hip arthroplasty, and those in the arthritis group and revision group underwent total hip arthroplasty. They were reviewed by medical records, clinically and radiologically


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 1 - 1
1 Apr 2018
Jo S Lee S Lim W Kim D Lee J
Full Access

Introduction

Cobalt chrome femoral head has been used widely in total hip arthroplasty and has shown favorable outcome. However, there is still of concern of potential metal toxicity from the wear debris. In the other hand, titanium is well known for its biocompatibility but it is not used in bearing surface of arthroplasty due to its brittleness. Recently, coating of the prosthesis using plasma electrolytic oxidation (PEO) has shown favorable surface protection. Thus, in this study, we tried to find out whether the PEO coating on the titanium surface would provide surface protection.

Materials and methods

Five Titanium alloy (Ti-6Al-4V) ball mimicking femoral head was manufactured and was coted using plasma electrolytic oxidation. Wear rate was tested using validated wear tester with 10N compression force at 80rpm. The amount of wear was detected by measuring change of weight after wear test was completed. This was compared with femoral head manufactured with titanium alloy without PEO coating. Toxicity of the debris was also tested using MTT assay with human osteoblast cell line.