Vol. 93-B, Issue SUPP_III | Pages 356 - 356
1 Jul 2011
Efstathopoulos N Xypnitos F Nikolaou V Lazarettos J Kaselouris E Venetsanos D Provatidis C
Full Access

We investigated the effect of the location and the number of distal screws in the efficiency of an intramedullary nail implementing the finite element method (FEM).

The left proximal femur of a 93-year old man was scanned and two series of full 3D models were developed. The first series, consisting of five models, concerned the use of a single distal screw inserted in five different distal locations. The second series, consisting of four models, concerned the use of four different pairs of distal screws. Each model was analyzed with the (FEM) twice, first considering that the femur is fractured and then considering that the femur is healed.

For nails with a single distal screw, stresses around the nail hole were reduced with proximal placement of the distal screw but the area around the nail hole where the lag screw is inserted is stressed more. Furthermore, for nails with a pair of distal screws, placing the pair of distal screws at a specific location is most beneficial for the mechanical behavior of the femur/nail assembly.

The distal area of the nail generally gets less stressed when a pair of distal screws is introduced, while the presence of two distal screws far away from each other results in lower proximal femoral head displacements. The stress field at the area of fracture is not influenced significantly by the presence of a single distal screw or a pair of distal screws.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 358 - 358
1 Jul 2011
Efstathopoulos N Sourlas J Lazarettos J Nikolaou V Brilakis E Xypnitos F
Full Access

To evaluate the clinical outcome of arthroscopic treatment of ACL with an Achilles tendon allograft in patient with acute rupture.

22 patients, between 2003 and 2006, with acute rupture of ACL, were treated with an Achilles tendon allograft. The mean age was 26 years. Patients were evaluated before and after surgery and at the latest follow-up with Noulis-Lahmann test and Pivot shift test. We also used IKDC score, Lysholm score and one leg stance test and functional reach test. Patients were also evaluated with Cybex II + and with plain radiographies.

The mean follow-up time was 3.5 years. 90% of the patients had a negative pivot shift test and 95% of the patients had a score at Noulis-Lahmann test +1. The mean value of IKDC score was 88 (62–100) and the mean time of Lysholm score was 91 (75–100). Until the latest follow-up there were no clinical sighs of inflammation or graft rejection. Radiologic evaluation revealed no sign of tunnel enlargement.

We believe that the use of a fresh-frozen allograft in the treatment of acute ACL ruptures is an effective procedure for the restoration of ligamentous stability of the knee.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 129 - 129
1 Mar 2009
Efstathopoulos N Bourboulis EG Lazarettos J Nikolaou V Tsaganos T Koutoukas P Papalois A Tsiolis P Xypnitos F
Full Access

AIM: Chronic osteomyelitis is a difficult to treat infection requiring prolonged antimicrobial therapy and involving systems of local antimicrobial delivery. Linezolid is a new antimicrobial agent with well documented in vitro activity against gram positive cocci when resistance to other antistaphylococcal agents is present. Few data are present regarding its embedding in local antimicrobial delivery systems and subsequent elution. The elution of linezolid by a polylactic acid (PLA) system was studied.

METHODS: Linezolid was dry-mixed with PLA at a ratio of 1:9, ie 50mg of linezolid were mixed with 450mg PLA. The mixture was diluted with 0,5mL of methanol and placed at the bottom of a cylindrical vial. Two replicas were created and one mL of Mueller-Hinton broth was added over the free solid surface of each mixture. Vials were transferred to a 37°C incubator and broth was replaced every 48h for 11 days. Concentration of linezolid was determined by an HPLC method using a Zorbax Eclipse XDB-C8 column and UV detection.

RESULTS: Mean linezolid concentration at days 1, 3, 5, 7, 9 and 11 was 2778.54 mg/L, 2456.22 mg/L, 668.63 mg/L, 324.86 mg/L, 390.10 mg/L, and 155.28 mg/L respectively.

CONCLUSION: Elution of linezolid by a PLA local delivery system remains very high throughout the period studied. The results are promising for the therapy of staphylococcal chronic osteomyelitis with the use of a PLA local antimicrobial delivery system employing linezolid.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 179 - 179
1 Mar 2006
Lazarettos J Nikolaou V Efstathopoulos N Pneumaticos S Plessas S Papachristou G
Full Access

Aim: To evaluate the feasibility of Norian S.R.S in the treatment of comminuted distal radius fractures.

Material and methods: 24 patients with comminuted distal radius fractures were open reduced and preserved with external fixation. The bone gaps were filled with Norian S.R.S. The wrist was mobilized at the 3rd postoperative week and the external fixation was removed the 4th–6th postoperative week, when the fracture healing was radiologically confirmed. All the patients had regular clinical and radiological control the first postoperative date and the 1rd, 3rd, 4th postoperative week and monthly until the 9th postoperative month.

Results: In the postoperative follow-up we didn’t note any loss of reduction and the joint range of motion compared with the contralateral exceeded 50% in 3 months and came close to 85% in 6 months. There were no clinically significant adverse effects or complications.

Conclusions: We believe that the use of Norian S.R.S. offers the potential for filling bony voids, does not exhibit tissue reactions and is progressively absorbed. The results of this study are comparable with other therapeutic approaches. Additionally, the use of the Norian S.R.S offers the potential of earlier mobilization and as an implant is bioabsobable through osteoclastic activity. In conclusion we believe that use of Norian S.R.S in the filling of bony defects in the comminuted distal radius fractures is a reliable and safe method of treatment.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 70 - 71
1 Mar 2006
Efstathopoulos N Nikolaou V Lazarettos J Psixas X Xypnitos F Papachristou G
Full Access

Aim: To compare two implants, the Gamma Nail and the ACE Trochanteric Nail in the treatment of pertrochanteric femoral fractures.

Patients and methods: Sixty patients were randomized on admission to two treatment groups. Thirty patients were treated with the Gamma nail implants , and thirty had intramedullary fixation with ACE Trochanteric NailI . The average age of these patients was 79 years. 22 patients were men and 38 women. 11 fractures were stable and 49 unstable. Patients were followed for 1 year and had a regular clinical and radiological review at 1, 3 and 6 months postoperatively. Operation time, intra-operative blood loss and blood transfusion and complications were recorded. The mobility score was used to assess the preinjury and postoperative mobility status. All the patients were operated within 24 hours after their accident and 39 of them within the first 6 hours.

Results: There were no complications during the surgery. All the patients were mobilized the first 24 hours post operatively irrespectively of the fracture’s type, and weight bearing was permitted as tolerated. The mean follow up time was 8 months (range 6 to 12 months). 3 patients were lost at the follow up and 2 died. Union of the fracture was achieved in all 55 patients. There was no statistically significant difference between the two groups with regard to intraoperative blood loss and the duration of the surgery. There was no mechanical failure of the implants despite the early patients mobilization. All the patients achieved mobility status similar to the preoperative at the latest follow up.

Conclusions: Based on our study, intramedullary nailing of pertrochanteric hip fractures represents a reliable method of treatment. We did not observe any differences in the two patient groups concerning the operation time, the intraoperative blood loss, the postoperative complications and the patients functional status at the latest follow up.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 164 - 164
1 Mar 2006
Efstathopoulos N GiamarellosBourboulis E Lazarettos J Nikolaou V Baziaka F Panousis C
Full Access

Sepsis and multiple-organ failure are common sequelae of multiple trauma. Although sepsis is considered to result from bacteria translocating through the gut mucosa, evidence for that is lacking. In order to define the chronic involvement of bacterial translocation, fracture was induced after crushing of the right femor on its mid in 11 rabbits. Blood was collected at regular time intervals for quantitative culture and for estimation of endotoxins (LPS) by the QCL LAL-assay, tumor necrosis factor-alpha (TNFalpha) by a bioassay in L929 fibrosarcoma cell line and malondialdehyde (MDA) by HPLC. After death, segments of liver, lung and spleen were cut for quantitative culture. Mean +/−SE of the log10 of viable cells in blood were 2.48 +/− 0.43, 3.16 +/− 0.46, 2.77 +/− 0.69 and 2.12 +/− 0.43 at 2, 4, 24 and 48 hours after fracture. Respective values for LPS were 1.50 +/−0.29, 1.54 +/− 0.44, 1.17 +/− 0.17 and < 1.00; for MDA 3.57 +/− 0.55, 7.50 +/− 3.00, 15.77 +/− 12.26 and 5.07 +/− 2.18 μM; and for TNFalpha 11.8 +/− 1.2, 36.7 +/− 25.9, 40.7 +/− 24.0 and 56.8 +/− 45.3 pg/ml. Positive tissue cultures for Serratia marscecens and Pseudomonas aeruginosa were found for six rabbits. Median survival for animals drawn positive tissue cultures was 1.00 days and 7.00 days for animals with negative tissue cultures (p: 0.0092). It is concluded that bacterial translocation is a process occurring early in a significant percentage in the field of multiple trauma. Its occurrence is accompanied by rapid progression to death. Further research is mandatory to clarify the reasons favoring that process in certain hosts compared to others.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 253 - 253
1 Mar 2004
Efstathopoulos N Lazarettos J Papachristou G Tsifetakis S Panousis K Nikolaou B
Full Access

Aims: The evaluation of the results becoming from the use of demineralized bone matrix (DBM) in the bone defects. Methods: In the present study the above substance was implanted during the period 2000-2002 (28 months) to 24 patients, 11 males and 13 females average age 39,1 for the males and 60 for the females. As a cause was referred in 12 patients the fall, in 3 patients the car crash, in 5 patients the following the removal of osteosynthesis materials, in 2 patients the bone cysts, in 1 patient fracture of ankle joint following fusion and in 1 patient a pseudarthrosis. The implantation of DBM concerned 8 hips, 4 femurs, 6 knees, 1 humerus, 1 forearm, 1 ankle, 2 metacarpal and 1 phalanx. All the fractures as well the fusion were treated through internal fixation. There was a regular post op follow-up and concerned the clinical and x-ray examination per month until the total incorporation of the graft (12 weeks). Results: In all patients the total incorporation of the DBM was accomplished in a brief period of time, depended on the place of implantation without having local or systemic side effects. We have to remark the early signs of bone shadow around the 3rd week, as well the incorporation of the matrix around the 12th week in the x-ray findings. Conclusions: The use of DBM in bone defects could play an important role to the filling of bone defrects due to fractures or benign cysts as a result of its incorporation and without inducing local or systematic side effects.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 326 - 326
1 Mar 2004
Efstathopoulos N Lazarettos J Frangia K Plessas S Magnisalis E Papalois A
Full Access

Aims: The effectiveness of the local treatment of experimental osteomyelitis caused by MRSA (Methicillin Resistant Staph. aureus) performed with the implantation of acrylic bone cement (PMMA) mixture plus 4% grepaßoxacin into the femur of rabbits. Methods: 36 rabbits with chronic MRSA osteomyelitis of the right femur (Norden Model) were treated with a new local grepaßoxacin delivery system prepared by a mixture of PMMA plus 4% grepaßoxacin. Osteomyelitis was introduced by inoculating of the MRSA and the placement of a needle serving as a foreign body. The follow-up of the infection was performed by clinical, microbiological and x-rays þndings. On the 3rd week all animals were reoperated and the needle was removed followed by implantation of the mixture. One control and þve treated animals were sacriþced each week thereafter until the 6th week. Results: Osteomyelitis was induced in all rabbits. The in vitro grepaßoxacin levels were high for 6 weeks at least. Concerning the histological þndings serious tissue reactions were not observed. The lesions and the bone structure are progressively rehabilated after the implantation. The biomechanical study didnñt inßuence the mechanical properties of bone cement due to grepaßoxacin. Conclusions: The above mixture could be an approved supplementary method for the treatment of bone infections. In the chronic osteomyelitis itñs possible to replace the gentamycin PMMA beads. Furthermore could be use as a spacer in loosen arthroplasties due infection in combination with antibiotic administration.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 326 - 326
1 Mar 2004
Lazarettos J Efstathopoulos N Papachristou G St T Plessas S
Full Access

Aims: The effectiveness of the local treatment of experimental osteomyelitis by MRSA with a mixture of calcium phosphate bone cement and 3% teicoplanin into the femur of rabbits. Methods: Thirty-six male rabbits with chronic (3 weeks) MRSA (Methicillin Resistant Staph. aureus) osteomyelitis of the right femur (Model of Norden CW) were treated with a new local Teico-planin delivery system prepared by a mixture of calcium phosphate cement plus 3% teicoplanin. Osteomyelitis was introduced by inoculating 107 cfu/ml of the MRSA strain in a 2mm hole of the bone medula, placement of a needle serving as a foreign body and subsequent closure with a sterile bone wax. The follow-up of the infection was performed by clinical, microbiological, x-rays and histological þndings. On the third week all animals were reoperated and the needle was removed followed by implantation of the above mixture. One control and þve treated animals were sacriþced each week thereafter until the sixth week. Results: Cultures of the treated animals were positive during the þrst week but turned negative after the second week, while throughout the same period cultures from the controls remain positive. Clinical and histologic studies were in accordance. Conclusions: The above mixture could be approved as a supplementary method in the treatment of bone infections. It can be used by replacing the gentamycin polymethyl-methacrylate beads whose use demands reoperation to be removed. Finally it offers the possibility to contribute to the þlling of the bone gaps as it can be replaced by host bone.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 212 - 212
1 Mar 2003
Papachristou C Efstathopoulos N Lazarettos J Kalliakmanis A Sourlas J Nikolaou V Chronopoulos E
Full Access

Purpose: The aim of this paper is to present a new surgical method for the reconstruction of the recurrent sprain of the ankle.

Material – Methods: From 1980 until 1997, 17 patients 3 females and 14 males, average age 25.53 (19 – 44) underwent surgery suffering recurrent sprain of the ankle. In 11 patients the right ankle was involved and in 6 patients the left ankle. The cause of the injury was: athletic activities in 9 cases, weekend activities in 7 cases and daily activities in 1 case.

The patients were suffering from ankle instability 4–15 years prior the operation. All the patients underwent reconstructive surgery of the anterolateral elements (capsule and ligaments) according to senior author’s method. This included shortening of the anterolateral elements, capsule and ligaments, overlaping the anterolateral part over the anterolateral one in such a way, that the anterior drawer and varus tests were negative with the patient under anaesthesia.

Results: The follow up is 2–12 years. A patient underwent for a second time surgery, because of a new injury. In 2 patients early signs of ankle osteoarthritis. In the rest of them, restoration of the function of the ankle joint was excellent, obtaining full activities 3 months postperatively.

Conclusion: This surgical method for the reconstruction of the recurrent sprain of the ankle is considered satisfactory and when indicated allows young patients and athletes to participate in a rather short period of time, in their previous level of activities.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 217 - 218
1 Mar 2003
Lazarettos J Efstathopoulos N Papachristou C Kanellakopoulou K Giamarellou E Kapranou A Elemenoglou J Papalois A
Full Access

Aims: The effectiveness of the local treatment of experimental osteomyelitis by MRSA with a mixture of calcium phosphate bone cement and 3% teicoplanin into the femur of rabbits.

Methods: Thirty-six male rabbits with chronic (3 weeks) MRSA (Methicillin Resistant Staph. aureus) osteomyelitis of the right femur (Model of Norden CW) were treated with a new local Teicoplanin delivery system prepared by a mixture of calcium phosphate cement plus 3% teicoplanin. Osteomyelitis was introduced by inoculating 107 cfu/ml of the MRSA strain in a 2mm hole of the bone medula, placement of a needle serving as a foreign body and subsequent closure with a sterile bone wax. The follow-up of the infection was performed by clinical, microbiological, x-rays and histological findings. On the third week all animals were reoperated and the needle was removed followed by implantation of the above mixture. One control and five treated animals were sacrificed each week thereafter until the sixth week.

Results: Cultures of the treated animals were positive during the first week but turned negative after the second week, while throughout the same period cultures from the controls remain positive. Clinical and histologic studies were in accordance.

Conclusions: The above mixture could be approved as a supplementary method in the treatment of bone infections. It can be used by replacing the gentamycin polymethylmethacrylate beads whose use demands reoperation to be removed. Finally it offers the possibility to contribute to the filling of the bone gaps as it can be replaced by host bone.