Severe heterotopic ossification (grade III and IV) after contemporary total hip arthroplasty (THA) requiring excision is very uncommon. We performed a systematic review of the literature, and report a new case series with operative treatment after primary uncemented THA. A systematic review identified papers describing patients who had excision of heterotopic ossification (HO) after contemporary THA, defined as performed after 1988. Concepts of hip arthroplasty, heterotopic ossification, and surgical excision were searched in MEDLINE, Embase, and Scopus, from database inception to November 2022. Inclusion criteria were: articles that included specific patient data on grade of heterotopic ossification, operative procedure, and prophylaxis. Studies were screened for inclusion by two independent reviewers. Extracted data included demographic data, interval from index surgery to excision, clinical results, and complications. One surgeon performed reoperation for ankylosis of primary THA in three patients with severe pain and deformity. Seven case series or case report studies were included. There were 41 patients, with grade III or IV HO, that had excision, and in five patients, revision of a component was also performed. Perioperative prophylaxis was irradiation alone in 10 patients, irradiation and indomethacin in 10, and indomethacin alone in 21 patients. At a mean follow-up time of 14.8 months, definition of the results was not uniform, and range of motion was improved, but relief of pain was inconsistent. There was one dislocation, one gastrointestinal complication, and two recurrences. Treatment of the three patients, with wide excision of peri-articular bone, selective exchange of components, and peri-operative irradiation prophylaxis, was successful in improving motion and deformity. There is insufficient data on the treatment of severe symptomatic HO after contemporary THA. Prophylaxis with low-dose irradiation was successful to prevent recurrence. Multicenter studies will be needed to determine the optimum timing and prognosis for treatment.
Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years. Using the database of
a single academic centre, 126 revision THAs in 117 patients using a single
design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for aseptic loosening, and acetabular revision for any reason. The secondary endpoints were surgical complications and the radiological outcome.Aims
Methods
To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period. This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.Aims
Methods
There are case series of debonding of the ATTUNE® tibial component introduced in 2013. We studied the early clinical results of this total knee arthroplasty (TKA) and compared it to other designs at one hospital. This is a retrospective study of 223 consecutive, non-randomized, cemented fixed-bearing posterior-stabilized ATTUNE® TKAs at one hospital by 5 surgeons from 2013 through 2017. We excluded 4 knees with early infection and 53 with follow-up less than 6 months. Of 166 TKAs reviewed, the mean patient age was 63.8 years, mean BMI 32, and mean follow-up 25 months. We compared this to a “control” cohort of 511 TKAs of other manufacturers performed at the same hospital. The endpoints were revision performed and revision pending.Background
Methods
Modular dual mobility (MDM) acetabular components are often used to prevent dislocation in revision total hip arthroplasty (THA). As there is insufficient data on these components, the outcomes were evaluated in a cohort with a mean follow-up time of greater than five years. Using the database of a single academic center, 126 revision THAs (117 patients) with one MDM were retrospectively reviewed. There were 94 hips in 88 patients with a mean follow-up time of 5.5 years. Survivorship analysis was performed with the endpoints of dislocation, reoperation for dislocation, cup revision for aseptic loosening, and cup revision for any reason. The secondary endpoints were perioperative complications and radiographic review.Background
Methods
There is insufficient data on the trends of anticoagulation after total knee arthroplasty (TKA) in the USA, and the efficacy and safety of rivaroxaban, beyond randomized clinical trials and small cohort studies. Using the Truven Health MarketScan database, we retrospectively evaluated new anticoagulation prescriptions after elective TKA from 2010 to 2015. The frequency of deep vein thrombosis (DVT), pulmonary embolism (PE), and adverse events, within 90 days, were then evaluated in 24,856 new users of warfarin and 21,398 new users of rivaroxaban in commercially insured patients (COM), and 15,483 new users of warfarin and 8,997 new users of rivaroxaban in Medicare supplement patients (MED). Data was analyzed by odds ratios using logistic regression models with stabilized inverse probability treatment weighting.Introduction
Patients and Methods
There is insufficient evidence to recommend the use of alternative polyethylene bearings in modular, fixed-bearing total knee arthroplasty (TKA). The purpose of this study was to compare standard polyethylene (SP) and highly crosslinked polyethylene (XLP) tibial liners in posterior-stabilized TKA, with osteolysis as the primary outcome and clinical results and the rate of re-operation as the secondary outcomes. This is a single-surgeon, prospective randomized study involving one design of modular posterior-stabilized TKA. An analysis of 122 TKAs with an SP compression moulded liner and 123 with an XLP liner was performed, with a mean follow-up of six years (2 to 11). Patients were evaluated clinically using the Knee Society score, Lower Extremity Activity Score (LEAS), and the presence of an effusion, and standard radiographs were assessed for radiolucent lines and osteolytic lesions.Aims
Patients and Methods
Patients may present with concurrent symptomatic osteoarthritis (OA) of the hip and degenerative disorders of the lumbar spine, with surgical treatment being indicated for both. Whether arthroplasty of the hip or spinal surgery should be performed first remains uncertain. Clinical scenarios were devised for a survey asking the preferred order of surgery and the rationale for this decision for five fictional patients with both OA of the hip and degenerative lumbar disorders. These were symptomatic OA of the hip and: 1) lumbar spinal stenosis with neurological claudication; 2) lumbar degenerative spondylolisthesis with leg pain; 3) lumbar disc herniation with leg weakness; 4) lumbar scoliosis with back pain; and 5) thoracolumbar disc herniation with myelopathy. This survey was sent to 110 members of The Hip Society and 101 members of the Scoliosis Research Society. The choices of the surgeons were compared among scenarios and between surgical specialties using the chi-squared test. The free-text comments were analyzed using text-mining.Aims
Materials and Methods
Polyethylene wear and osteolysis remain a concern with the use of modular, fixed bearing total knee arthroplasty (TKA). A variety of highly cross-linked polyethylenes (XLPs) have been introduced to address this problem, but there are few data on the results and complications of this polyethylene in posterior-stabilized knee prosthesis. We have previously reported an interim analysis of a study comparing polyethylene tibial liners. This is a prospective randomized study of one modular posterior-stabilized total knee arthroplasty by a single surgeon. 265 patients (329 knees) were randomized to receive a standard compression molded liner (SP) or a highly cross-linked (6.5 CGy electron-beam irradiated and remelted) polyethylene liner (XLP). Patients were evaluated clinically using the classic Knee Society scores, LEAS score, presence of a knee effusion, and by standard radiographs for radiolucent lines and osteolytic lesions. The analysis was performed at a mean of 6 years (range, 2–11 years).Introduction
Methods
Many pharmacologic agents have been used for venous thromboembolism (VTE) prophylaxis after elective total hip arthroplasty (THA). Rivaroxaban was the first novel oral anticoagulant approved for THA patients, but its actual efficacy and safety in clinical practice, beyond randomized trials, is unknown. This is a retrospective study, using the Truven Health MarketScan database, of anticoagulation medication prescriptions after elective THA, in both commercially insured (CI) and Medicare supplement insured (MS) patients, from 2010 to 2015. After exclusions, there were 83,179 CI and 50,534 MS patients available for analysis. There were 12,876 new users of warfarin (W) and 10,892 new users of rivaroxaban (R) in CI patients, and 7,416 new users of W and 4,739 new users of R in MS patients. We asked the following questions: (1) What were the trends and predictive factors for anticoagulant use after elective THA? (2) What was the actual clinical efficacy: frequency of deep vein thrombosis (DVT) and pulmonary embolism (PE), and frequency of adverse events within 90 days with the two most commonly used oral agents, rivaroxaban and warfarin, from June 2011 to September 2015? Data was analyzed for each anticoagulant by odds ratios using logistic regression models with stabilized inverse probability treatment weighting.Introduction
Materials and Methods
Patients may present with concurrent symptomatic hip and spine problems, with surgical treatment indicated for both. Controversy exists over which procedure, total hip arthroplasty (THA) or lumbar spine procedure, should be performed first, and does the surgeon's area of expertise influence the choice. Clinical scenarios were devised for 5 fictional patients with both symptomatic hip and lumbar spine disorders for which surgical treatment was indicated. An email with survey link was sent to 110 clinical members of the Hip Society and 101 experienced spine surgeons in the USA requesting responses to: which procedure should be performed first, and the rationale for the decision with comments. The clinical scenarios were painful hip osteoarthritis and (1) lumbar spinal stenosis with neurologic claudication; (2) lumbar degenerative spondylolisthesis with leg pain; (3) lumbar disc herniation with leg weakness; (4) lumbar scoliosis with back pain; and (5) thoracolumbar disc herniation with myelopathy. Surgeon choices were compared among scenarios and between surgical specialties using chi-square analysis and comments analyzed using text mining.Purpose
Materials & Methods
To report our experience with trunnion corrosion following metal-on-polyethylene
total hip arthroplasty, in particular to report the spectrum of
presentation and determine the mean time to presentation. We report the presenting symptoms and signs, intraoperative findings,
and early results and complications of operative treatment in nine
patients with a mean age of 74 years (60 to 86). The onset of symptoms
was at a mean of seven years (3 to 18) after index surgery.Aims
Patients and Methods
The ‘jumbo’ acetabular component is now commonly
used in acetabular revision surgery where there is extensive bone
loss. It offers high surface contact, permits weight bearing over
a large area of the pelvis, the need for bone grafting is reduced
and it is usually possible to restore centre of rotation of the
hip. Disadvantages of its use include a technique in which bone
structure may not be restored, a risk of excessive posterior bone
loss during reaming, an obligation to employ screw fixation, limited
bone ingrowth with late failure and high hip centre, leading to increased
risk of dislocation. Contraindications include unaddressed pelvic
dissociation, inability to implant the component with a rim fit,
and an inability to achieve screw fixation. Use in acetabulae with
<
50% bone stock has also been questioned. Published results
have been encouraging in the first decade, with late failures predominantly because
of polyethylene wear and aseptic loosening. Dislocation is the most
common complication of jumbo acetabular revisions, with an incidence
of approximately 10%, and often mandates revision. Based on published results,
a hemispherical component with an enhanced porous coating, highly
cross-linked polyethylene, and a large femoral head appears to represent
the optimum tribology for jumbo acetabular revisions. Cite this article:
Metaphyseal bone loss is common with revision
total knee replacement (RTKR). Using the Anderson Orthopaedic Research
Institute (AORI) classification, type 2-B and type 3 defects usually
require large metal blocks, bulk structural allograft or highly
porous metal cones. Tibial and femoral trabecular metal metaphyseal
cones are a unique solution for large bone defects. These cones
substitute for bone loss, improve metaphyseal fixation, help correct
malalignment, restore the joint line and may permit use of a shorter
stem. The technique for insertion involves sculpturing of the remaining
bone with a high speed burr and rasp, followed by press-fit of the
cone into the metaphysis. The fixation and osteoconductive properties
of the porous cone outer surface allow ingrowth and encourage long-term
biological fixation. The revision knee component is then cemented
into the porous cone inner surface, which provides superior fixation
compared with cementing into native but deficient metaphyseal bone.
The advantages of the cone compared with allograft include: technical
ease, biological fixation, no resorption, and possibly a lower risk
of infection. The disadvantages include: difficult extraction and
relatively short-term follow-up. Several studies using cones report
promising short-term results for the reconstruction of large bone
defects in RTKR. Cite this article:
Persistent groin pain after seemingly successful
total hip replacement (THR) appears to have become more common.
Recent studies have indicated a high incidence after metal-on-polyethylene
and metal-on-metal conventional THR and it has been documented in
up to 18% of patients after metal-on-metal resurfacing. There are many
causes, including acetabular loosening, stress fracture, and iliopsoas
tendonitis and impingement. The evaluation of this problem requires
a careful history and examination, plain radiographs and an algorithmic approach
to special diagnostic imaging and tests. Non-operative treatment
is not usually successful. Specific operative treatment depending
on the cause of the pain usually involves revision of the acetabular
component, iliopsoas tenotomy or other procedures, and is usually
successful. Here, an appropriate algorithm is described.
The optimal characteristics of pneumatic compression for mechanical prophylaxis of thromboembolism after total knee arthroplasty (TKA) are not known. Our study compared two methods of calf compression, with the hypothesis that the device which provided a larger increase in peak venous velocity would produce a lower rate of thromboembolism. We performed a prospective, randomised study on 423 patients (472 knees). Duplex ultrasonography was carried out by experienced technicians who were blinded to the device used. Overall, 206 patients (232 knees) used a rapid inflation, asymmetrical compression (RIAC) device and 217 (240 knees) a sequential circumferential compression device (SCD). The rate of venous thromboembolism was 6.9% with the RIAC device compared with 15% for the SCD device (p = 0.007). The incidence of thrombi with unilateral primary TKA was 8.4% for the RIAC compared with 16.8% for the SCD device (p = 0.03). In 47 patients with a bilateral TKA, the incidence of thrombi was 4% for the RIAC compared with 22.7% for the SCD device (p = 0.05 per knee). There was a low rate of mortality and pulmonary embolism when using mechanical prophylaxis for thromboembolism after TKA. Our findings show that the use of rapid inflation, asymmetrical calf compression gave a significantly lower rate of thromboembolism.