Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 4 - 4
1 Feb 2021
Coomer S LaCour M Khasian M Cates H Komistek R
Full Access

Introduction

The patella experiences large forces and variable kinematic patterns throughout flexion which could influence function and patient satisfaction after a total knee arthroplasty (TKA). Therefore, the objective of this study is to analyze in vivo patellar mechanism forces and kinematics throughout flexion to determine influencing factors that may lead to patient dissatisfaction.

Methods

Fifty subjects were evaluated in this study, 40 having a Journey II bi-cruciate stabilized (BCS) TKA and 10 having normal, healthy knees. Similar demographics were controlled for each group. Each subject performed a deep knee bend. Kinematics were evaluated using a validated 3D-to-2D fluoroscopic technique while forces were determined using a validated inverse mathematical knee model. A two-tailed t-test was used to evaluate statistical significance.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 18 - 18
1 Feb 2021
LaCour M Khasian M Jennings J Dennis D Komistek R
Full Access

Introduction

Many groups consider passive flexion to be a good indicator of postoperative success, to the point where this outcome directly influences certain outcome scores such as Knee Society Scores (KSS). However, it is alternatively believed that normal-like kinematics result in better TKA outcomes, and previous fluoroscopy studies have demonstrated that there are many parameters that affect weight-bearing range-of-motion. The objective of this study to investigate the correlations between patient-reported outcomes, passive flexion, and weight-bearing knee kinematics.

Methods

The femorotibial kinematics, passive and weight-bearing range-of-motion, and KOOS and KSS for 291 TKA subjects were collected in a retrospective study. The average age, BMI, and post-op time was 69.2±7.2 years, 29.3±4.6, and 22.4±16.3 months, respectively. Pearson correlation analysis was used to find the statistical correlations between the various parameters, and two-tailed t-tests were carried out to find statistical differences.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 32 - 32
1 Feb 2021
Dessinger G LaCour M Dennis D Kleeman-Forsthuber L Komistek R
Full Access

Introduction

Although surgical remedies tend to be the long-term solutions for patients with osteoarthritis (OA), many alternatives exist that offer the potential to slow progression, alleviate pain, and/or restore function. One such option is the unloader OA knee brace. The objective of this study was to assess the in vivo medial joint space narrowing with and without the brace during weight-bearing portion of gait.

Methods

Twenty subjects were evaluated after being clinically assessed by a single surgeon to be bone-on-bone on the medial side. In vivo gait kinematics were collected using a validated 3D-to-2D fluoroscopic registration technique (Figure 1). Subjects were asked to first walk on a treadmill without a brace (Figure 2), and then, after a qualified technician fit a properly sized brace to each subject, they were asked to walk again (Figure 3). In vivo fluoroscopic images were captured and registered at heel-strike (HS) and mid stance (MS) for both scenarios. CT scans were used to acquire the patient-specific bone models that were used in the registration process.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 14 - 14
1 Feb 2021
LaCour M Ta M Callaghan J MacDonald S Komistek R
Full Access

Introduction

Current methodologies for designing and validating existing THA systems can be expensive and time-consuming. A validated mathematical model provides an alternative solution with immediate predictions of contact mechanics and an understanding of potential adverse effects. The objective of this study is to demonstrate the value of a validated forward solution mathematical model of the hip that can offer kinematic results similar to fluoroscopy and forces similar to telemetric implants.

Methods

This model is a forward solution dynamic model of the hip that incorporates the muscles at the hip, the hip capsule, and the ability to modify implant position, orientation, and surgical technique. Muscle forces are simulated to drive the motion, and a unique contact detection algorithm allows for virtual implantation of components in any orientation. Patient-specific data was input into the model for a telemetric subject and for a fluoroscopic subject.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 48 - 48
1 Feb 2021
Khasian M LaCour M Dennis D Komistek R
Full Access

Introduction

A common goal of total knee arthroplasty (TKA) is to restore normal knee kinematics. While substantial data is available on TKA kinematics, information regarding non-implanted knee kinematics is less well studied especially in larger patient populations. The objectives of this study were to determine normal femorotibial kinematics in a large number of non-implanted knees and to investigate parameters that yield higher knee flexion with weight-bearing activities.

Methods

Femorotibial kinematics of 104 non-implanted healthy subjects performing a deep knee bend (DKB) activity were analyzed using 3D to 2D fluoroscopy. The average age and BMI were 38.1±18.2 years and 25.2±4.6, respectively. Pearson correlation analysis was used to determine statistical correlations.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 70 - 70
1 Feb 2020
Khasian M LaCour M Dessinger G Meccia B Komistek R
Full Access

Introduction

Forward solution joint models (FSMs) can be powerful tools, leading to fast and cost-efficient simulation revealing in vivo mechanics that can be used to predict implant longevity. Unlike most joint analysis methods, mathematical modeling allows for nearly instantaneous evaluations, yielding more rapid surgical technique and implant design iterations as well as earlier insight into the follow-up outcomes used to better assess potential success. The current knee FSM has been developed to analyze both the kinematics and kinetics of commercial TKA designs as well as novel implant designs.

Objective

The objective of this study was to use the knee FSM to predict the condylar translations and axial rotation of both fixed- and mobile-bearing TKA designs during a deep knee bend activity and to compare these kinematics to known fluoroscopy evaluations.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 93 - 93
1 Feb 2020
Ta M Nachtrab J LaCour M Komistek R
Full Access

Introduction

Conventional hip radiographs allow surgeons, during preoperative planning, to make important decisions. Size and location of implants are routinely measured by overlaying schematics of the implanted components onto preoperative radiographs. Most currently available planning tools are in two-dimensions (2D), using X-ray images and 2D templates of the implants. Determination of the ideal component size requires two radiographic views of the femur: the anterior-posterior (AP) and the lateral direction. The surgeon uses this information to determine component sizes. Even though this approach has been used for many years leading to very good results, this manual process potentially carries multiple shortcomings. The biggest issue with the AP X-ray image is the fact that it is 2D in nature while the measurement's objective is to obtain three-dimensional (3D) parameters.

Objective

The objective of this study is to derive a methodology to automatically select correct THA implant sizes while keeping the anatomical center of each specific patient within a forward solution model (FSM) that predicts post-operative outcomes.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 61 - 61
1 Feb 2020
LaCour M Nachtrab J Ta M Komistek R
Full Access

Introduction

Traditionally, conventional radiographs of the hip are used to assist surgeons during the preoperative planning process, and these processes generally involve two-dimensional X-ray images with implant templates. Unfortunately, while this technique has been used for many years, it is very manual and can lead to inaccurate fits, such as “good” fits in the frontal view but misalignment in the sagittal view. In order to overcome such shortcomings, it is necessary to fully describe the morphology of the femur in three dimensions, therefore allowing the surgeon to successfully view and fit the components from all possible angles.

Objective

The objective of this study was to efficiently describe the morphology of the proximal femur based on existing anatomical landmarks for use in surgical planning and/or forward solution modeling.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 81 - 81
1 Feb 2020
Dessinger G Nachtrab J LaCour M Komistek R
Full Access

Introduction

Untreated hip osteoarthritis is a debilitating condition leading to pain, bone deformation, and limited range of motion. Unfortunately, studies have not been conducted under in vivo conditions to determine progressive kinematics variations to a hip joint from normal to pre-operative and post-operative THA conditions. Therefore, the objective was this study was to quantify normal and degenerative hip kinematics, compared to post-operative hip kinematics.

Methods

Twenty unique subjects were analyzed; 10 healthy, normal subjects and 10 degenerative, subjects analyzed pre-operatively and then again post-operatively after receiving a THA. During each assessment, the subject performed a gait (stance and swing phase) activity under mobile, fluoroscopic surveillance. The normal and diseased subjects had CT scans in order to acquire bone geometry while implanted subjects had corresponding CAD models supplied. Femoral head and acetabular cup centers were approximated by spheres based on unique geometries while the component centers were pre-defined as the center of mass. These centers were used to compare femoral head sliding magnitudes on the acetabular cup during the activity for all subjects. Subjects were noted to have separation with changes in center magnitudes of more than 1 mm during gait. Utilizing 3D-to-2D registration techniques, the hip joint kinematics were derived and assessed. This allowed for visualization of normal subject positioning, pre-op bone deterioration, and implant placement within the bones.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 137 - 137
1 Feb 2020
Dessinger G Argenson J Bizzozero P LaCour M Komistek R
Full Access

Introduction

Numerous fluoroscopic studies have been conducted to investigate kinematic variabilities of total knee arthroplasty (TKA). In those studies, subjects having a posterior stabilized (PS) TKA experience greater weightbearing knee flexion and posterior femoral rollback of the lateral condyle. In those same studies, subjects did experience a high incidence of variable medial condyle motion and reverse axial rotation, especially occurring when the cam engaged the post. More recently, a PS TKA was designed to accommodate both gender and ethnicity. Therefore, the objective of this study was to assess in vivo kinematics for subjects having this TKA type to determine if subjects having this PS TKA experienced more optimal knee kinematics.

Methods

Twenty-five subjects in this study were asked to perform a deep knee bend to maximum knee flexion and a step-up maneuver while under fluoroscopic surveillance. All subjects were patients of one experienced surgeon and received the same PS TKA. Using a 3D-2D registration technique, the CAD models, supplied by the sponsoring company, were superimposed over x-ray images at specified increments throughout the fluoroscopic footage. The kinematics were then analyzed to evaluate lateral anterior/posterior (LAP) and medial anterior/posterior (MAP) condyle translation as well as axial rotation of the femur with respect to the tibia.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 94 - 94
1 Feb 2020
Ta M Nachtrab J LaCour M Komistek R
Full Access

Introduction

Obtaining accurate anatomical landmarks may lead to a better morphologic understanding, but this is challenging due to the variation of bony geometries. A manual approach, non-ideal for surgeons or engineers, requires a CT or MRI scan, and landmarks must be chosen based on the 3D representation of the scanned data. Ideally, anatomical landmarking is achieved using either a statistical shape model or template matching. Statistical modeling approaches require multitude of training data to capture population variation. Prediction of anatomical landmarks through template matching techniques has also been extensively investigated. These techniques are based on the minimization or maximization of an objective or cost function. As is the nature of non-rigid algorithms, these techniques can fail in the local maxima if the template and new bone models have noise or outliers. Therefore, a combination of rigid and non-rigid registration techniques is needed, in order to obtain accurate anatomical landmarks and improve the prediction process.

Objective

The objective of this study was to find a way to efficiently obtain accurate anatomical landmarks based on an existing template's landmarks for use in a forward solution model (FSM) to predict patient specific mechanics.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 62 - 62
1 Feb 2020
LaCour M Nachtrab J Ta M Komistek R
Full Access

Introduction

Previous research defines the existence of a “safe zone” (SZ) pertaining to acetabular cup implantation during total hip arthroplasty (THA). It is believed that if the cup is implanted at 40°±10° inclination and 15°±10° anteversion, risk of dislocation is reduced. However, recent studies have documented that even when the acetabular cup is placed within the SZ, high incidence dislocation and instability remains due to the combination of patient-specific configuration, cup diameter, head size, and surgical approach. The SZ only investigates the angular orientation of the cup, ignoring translational location. Translational location of the cup can cause a mismatch between anatomical hip center and implanted cup center, which has not been widely explored.

Objective

The objective of this study is to define a zone within which the implanted joint center can be altered with respect to the anatomical joint center but will not increase the likelihood of post-operative hip separation or dislocation.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 95 - 95
1 Feb 2020
Ta M Nachtrab J LaCour M Komistek R
Full Access

Summary

The mathematical model has proven to be highly accurate in measuring leg length before and after surgery to determine how leg length effects hip joint mechanics.

Introduction

Leg length discrepancy (LLD) has been proven to be one of the most concerning problems associated with total hip arthroplasty (THA). Long-term follow-up studies have documented the presence of LLD having direct correlation with patient dissatisfaction, dislocation, back pain, and early complications. Several researchers sought to minimize limb length discrepancy based on pre-operative radiological templating or intra-operative measurements. While often being a common occurrence in clinical practice to compensate for LLD intra-operatively, the center of rotation of the hip joint has often changes unintentionally due to excessive reaming. Therefore, the clinical importance of LLD is still difficult to solve and remains a concern for clinicians.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 100 - 100
1 Feb 2020
Khasian M LaCour M Coomer S Komistek R
Full Access

Background

Although early TKA designs were symmetrical, during the past two decades TKA have been designed to include asymmetry, pertaining to either the trochlear groove, femoral condylar shapes or the tibial component. More recently, a new TKA was designed to include symmetry in all areas of the design, in the hopes of reducing design and inventory costs.

Objective

The objective of this study was to determine the in vivo kinematics for subjects implanted with this symmetrical TKA during a weight-bearing deep knee bend activity.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 85 - 85
1 Feb 2020
Dessinger G LaCour M Komistek R
Full Access

Introduction

Diagnosis of osteoarthritis relies primarily on image-based analyses. X-ray, CT, and MRI can be used to evaluate various features associated with OA including joint space narrowing, deformity, articular cartilage integrity, and other joint parameters. While effective, these exams are costly, may expose the patient to ionizing radiation, and are often conducted under passive, non-weightbearing conditions. A supplemental form of analysis utilizing vibroarthrographic (VAG) signals provides an alternative that is safer and more cost-effective for the patient. The objective of this study is to correlate the kinematic patterns of normal, diseased (pre-operative), and implanted (post-operative) hip subjects to their VAG signals that were collected and to more specifically, determine if a correlation exists between femoral head center displacement and vibration signal features.

Methods

Of the 28 hips that were evaluated, 10 were normal, 10 were diseased, and 8 were implanted. To collect the VAG signal from each subject, two uniaxial accelerometers were placed on bony landmarks near the joint; one was placed on the greater trochanter of the femur and the other along the anterior edge of the iliac crest. The subjects performed a single cycle gait (stance and swing phase) activity under fluoroscopic surveillance. The CAD models of the implanted components were supplied by the sponsoring company while the subject bone models were created from CT scans. 3D-to-2D registration was conducted on subject fluoroscopic images to obtain kinematics, contact area, and femoral center head displacement. The VAG signals were trimmed to time, passed with a denoise filter and wavelet decomposition.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 61 - 61
1 Apr 2019
Ta M LaCour M Sharma A Komistek R
Full Access

During the preoperative examination, surgeons determine whether a patient, with a degenerative hip, is a candidate for total hip arthroplasty (THA). Although research studies have been conducted to investigate in vivo kinematics of degenerative hips using fluoroscopy, surgeons do not have assessment tools they can use in their practice to further understand patient assessment. Ideally, if a surgeon could have a theoretical tool that efficiently allows for predictive post-operative assessment after virtual surgery and implantation, they would have a better understanding of joint conditions before surgery.

The objectives of this study were (1) to use a validated forward solution hip model to theoretically predict the in vivo kinematics of degenerative hip joints, gaining a better understanding joint conditions leading to THA and (2) compare the predicted kinematic patterns with those derived using fluoroscopy for each subject.

A theoretical model, previously evaluated using THA kinematics and telemetry, was used for this study, incorporating numerous muscles and ligaments, including the quadriceps, hamstring, gluteus, iliopsoas, tensor fasciae latae, an adductor muscle groups, and hip capsular ligaments. Ten subjects having a pre-operative degenerative hip were asked to perform gait while under surveillance using a mobile fluoroscopy unit. The hip joint kinematics for ten subjects were initially assessed using in vivo fluoroscopy, and then compared to the predicted kinematics determined using the model. Further evaluations were then conducted varying implanted component position to assess variability.

The fluoroscopic evaluation revealed that 33% of the degenerative hips experienced abnormal hip kinematics known as “hip separation” where the femoral head slides within the acetabulum, resulting in a decrease in contact area. Interestingly, the mathematical model produced similar kinematic profiles, where the femoral head was sliding within the acetabulum (Figure 1).

During swing phase, it was determined that this femoral head sliding (FHS) is caused by hip capsular laxity resulting in reducing joint tension. At the point of maximum velocity of the foot, the momentum of the lower leg becomes too great for capsule to properly constrain the hip, leading to the femoral component pistoning outwards.

During stance phase, kinematics of degenerative hips were similar to kinematics of a THA subject with mal-positioning of the acetabular cup. Further evaluation revealed that if the cup was placed at a position other than its native, anatomical center, abnormal forces and torques acting within the joint lead to the femoral component sliding within the acetabular cup. It was hypothesized that in degenerative hips, similar to THA, the altered center of rotation is a leading influence of FHS (Figure 2).

The theoretical model has now been validated for subjects having a THA and degenerative subjects. The model has successfully derived kinematic patterns similar to subjects evaluated using fluoroscopy. The results in this study revealed that altering the native joint center is the most influential factor leading to FHS, or more commonly known as hip separation. A new module for the mathematical model is being implemented to simulate virtual surgery so that the surgery can pre- operatively plan and then simulate post-operative results.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 80 - 80
1 Apr 2019
Nachtrab J Dessinger G Khasian M LaCour M Sharma A Komistek R
Full Access

Introduction

Hip osteoarthritis can be debilitating, often leading to pain, poor kinematics and limiting range of motion. While the in vivo kinematics of a total hip arthroplasty (THA) are well documented, there is limited information pertaining to the kinematics of native, non-arthritic (normal) hips and degenerative hips requiring a THA.

The objective of this study is to evaluate and compare the in vivo kinematics of the normal hip with pre-operative, degenerative hips and post-operative THA.

Methods

Twenty subjects, ten having a normal hip and ten having a pre-operative, degenerative hip that were analyzed before surgery and then post-operatively after receiving a THA. Each subject was asked to perform gait while under mobile fluoroscopic surveillance. Normal and pre-operative degenerative subjects underwent a CT scan so that 3D models of their femur and pelvis could be created. Using 3D-to-2D registration techniques, the hip joint kinematics were derived and assessed.

Femoral head and acetabular cup rotational centers were derived using spheres. The centers of these spheres were used to obtain the femoral head sliding distance on the acetabular cup during the activity. The patient-specific reference femoral head values were obtained from the subjects’ CT scans in a non-weight bearing situation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 60 - 60
1 Apr 2019
Ta M LaCour M Sharma A Komistek R
Full Access

Currently, hip implant designs are evaluated experimentally using mechanical simulators or cadavers, and total hip arthroplasty (THA) postoperative outcomes are evaluated clinically using long-term follow-up. However, these evaluation techniques can be both costly and time-consuming. Neither can provide an assessment of post-operative results at the onset of implant development. More recently, a forward-solution mathematical model was developed that functions as theoretical joint simulator, providing instant feedback to designers and surgeons alike. This model has been validated by comparing the model predictions with kinematic results from fluoroscopy for both implanted and non-implanted hips and kinetics from a telemetric hip. The model allows surgical technique modifications and implant component placement under in vivo conditions.

The objective of this study was to further expand the capabilities of the model to function as an intraoperative virtual surgical tool (Figure 1). This new module allows the surgeon to simulate surgery, then predict, compare, and optimize postoperative THA outcomes based on component placement, sizing choices, reaming and cutting locations, and surgical methods.

This virtual surgery tool simulates the quadriceps, hamstring, gluteus, iliopsoas, tensor fasciae latae, and an adductor muscle groups, as well as the hip capsular ligament groups. The model can simulate resecting, weakening, loosening, or tightening of soft tissues based on surgical techniques. Additionally, the model can analyze a variety of activities, including gait and deep flexion activities.

Initially, the virtual surgery module offers theoretical surgery tools that allow surgeons to alter surgical alignments, component designs, offsets, as well as reaming and cutting simulations. The virtual model incorporates a built-in CT scan bone database which will assist in determining muscle and ligament attachment sites as well as bony landmarks. The virtual model can be used to assist in the placement of both the femoral component and the acetabular cup (Figure 2).

Moreover, once the surgeon has decided on the placements of the components, they can use the simulation capabilities to run virtual human body maneuvers based on the chosen parameters. The simulations will reveal force, contact stress, and motion predictions of the hip joint (Figure 3). The surgeon can then choose to modify the positions accordingly or proceed with the surgery.

This new virtual surgical tool will allow surgeons to gain a better understanding of possible post-operative outcomes under pre-operative conditions or intra-operatively. Simulations using the virtual surgery model has revealed that improper component placement may lead to non-ideal post-operative function, which has been simulated using the model. Further evaluation is ongoing so that this new module can reveal more information pre-operatively, allowing a surgeon to gain ample information before surgery, especially with difficult and revision cases.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 38 - 38
1 Apr 2018
LaCour M Ta M Sharma A Komistek R
Full Access

Background

In vivo fluoroscopic studies have proven that femoral head sliding and separation from within the acetabular cup during gait frequently occur for subjects implanted with a total hip arthroplasty. It is hypothesized that these atypical kinematic patterns are due to component malalignments that yield uncharacteristically higher forces on the hip joint that are not present in the native hip. This in vivo joint instability can lead to edge loading, increased stresses, and premature wear on the acetabular component.

Objective

The objective of this study was to use forward solution mathematical modeling to theoretically analyze the causes and effects of hip joint instability and edge loading during both swing and stance phase of gait.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 37 - 37
1 Apr 2018
LaCour M Ta M Sharma A Komistek R
Full Access

Background

Extensive research has previously been conducted analyzing the biomechanical effects of rotational changes (i.e. version and inclination) of the acetabular cup. Many sources, citing diverse dislocation statistics, encourage surgeons to strive for various “safe zones” during the THA operation. However, minimal research has been conducted, especially under in vivo conditions, to assess the consequences of cup translational shifting (i.e. offsets, medial and superior reaming, etc.). While it is often the practice to medialize the acetabular cup intraoperatively, there is still a lack of information regarding the biomechanical consequences of such cup medializations and medial/superior malpositionings.

Objective

Therefore, the objective of this study is to use a validated forward solution mathematical model to vary cup positioning in both the medial and superior directions to assess simulated in vivo kinematics.