Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 13 - 13
1 May 2012
D. L M. M L. P K. M O. B M. L S. W H.Z. K
Full Access

Sclerostin is a negative regulator of osteoblast differentiation and bone formation, probably through inhibition of the Wnt pathway. Distraction osteogenesis (DO) can be complicated by osteopenia and poor anabolic response, which may benefit from anabolic therapy. Sclerostin antibody (Scl-Ab) has been reported to stimulate bone formation and restore bone mass and strength in aged ovariectomised rats as well as to enhance fracture healing. We sought to examine the effects of Scl-Ab in a rat model of DO.

A femoral osteotomy was stabilised with an EBI fixator in male Sprague Dawley rats, with distraction of 0.25mm twice daily to a total 7mm. Saline or Scl-Ab was administered twice weekly throughout distraction and/or up to 4 or 6 weeks post-commencement of distraction. Three groups were examined, Saline, Delayed Scl-Ab (D Scl-Ab, post distraction only) and Continuous Scl-Ab (Cont Scl-Ab).

Radiographs demonstrated a trend for increased union rates with Scl-Ab at 6 weeks, with 50% of animals for D Scl-Ab or Cont Scl-Ab versus 20% of control animals. DEXA scans at 2 weeks revealed a 63% increase in regenerate BMD in the Cont Scl-Ab group (p< 0.01) and a 41% increase in the D Scl-Ab group (p< 0.05), compared to Saline. In addition, an increase of 116% in BMC was seen in the Cont Scl-Ab group (p< 0.01). At 6 weeks regenerate bone area was increased 18% in D Scl-Ab and 23% in Cont Scl-Ab. μCT scans of the regenerate revealed an 85%-89% increase in bone volume with Scl-Ab treatment at 6 weeks (p< 0.05). Bone volume ratio (BV/TV) was increased 77%-82% (p< 0.05).

Scl-Ab treatment enhanced the amount of bone formed in this distraction model, when given throughout or post-distraction. Histological assessment of dynamic bone formation parameters will reveal the mechanism behind the enhanced repair, and its mechanical consequences will be examined.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 93 - 93
1 May 2012
L. P L. S C. H A. K J. L
Full Access

This prospective longitudinal study compared the results of isolated endoscopic ACL reconstruction utilising 4-strand hamstring tendon (HT) or patellar tendon (PT) autograft over 15-years with respect to reinjury, clinical outcomes and osteoarthritis.

Ninty consecutive patients with isolated ACL rupture were reconstructed with a PT autograft and 90 patients received HT autograft, with an identical surgical technique. Patients were assessed at 2, 5, 7, 10 and 15 years. Assessment included the IKDC Knee Ligament Evaluation, radiographic evaluation, KT1000, Lysholm Knee Score, kneeling pain, and clinical outcomes.

Subjects who received the PT graft had significantly worse outcomes compared to those who received the HT graft at 15 years for the variables of radiologically detectable osteoarthritis (p=0.03), motion loss (p=0.01), single leg hop test (p=0.002), participation in strenuous activity (p=0.05), and kneeling pain (p=0.04). There was no significant difference between the HT and PT groups in overall IKDC grade (p=0.31). ACL graft rupture occurred in 16% of HT group and 8% of the PT group (p=0.07). ACL graft rupture was associated with non-ideal tunnel position (odds ratio 5.0) and males (odds ratio 3.2). Contralateral ACL rupture occurred in significantly more PT patients (24%) than HT patients (12%) (p=0.03), and was associated with age < 18 years (odds ratio 4.1) and the patellar tendon graft (odds ratio 2.6). Radiologically detectable osteoarthritis at 15 years was associated with the PT graft (odds ratio 2.3).

Significant differences have developed in the groups at 15 years after surgery which were not seen at earlier reviews. Compared to the HT Group, the PT group had significantly worse outcomes with respect to radiological osteoarthritis, extension loss and functional tests but no significant difference in laxity was identified. There was a high incidence of ACL injury after reconstruction, to both the reconstructed and the contralateral knee.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 11 - 11
1 May 2012
L. P C. H L. S A. K H. W N. H W. VDT R. C
Full Access

Introduction

The management of degenerative arthritis of the knee in the younger, active patient presents a challenge to the orthopaedic surgeon. Surgical treatment options include: high tibial osteotomy (HTO), unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The aim of this study was to examine the long-term survival of closing wedge HTO in a large series of patients up to 19 years after surgery.

Methods

Four hundred and fifty-five consecutive patients underwent lateral closing wedge HTO for medial compartment osteoarthritis (MCOA) between 1990 and 2001. Between 2008-2009, patients were contacted via telephone. Assessment included: incidence of further surgery, current body mass index (BMI), Oxford Knee Score, and British Orthopaedic Association (BOA) Patient Satisfaction Scale. Failure was defined as the need for revision HTO or conversion to UKA or TKA. Survival analysis was completed using the Kaplan-Meier method.