header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 15 - 15
1 May 2019
Heaver C Hyne M Kuiper J Lewthwaite S Burston B Banerjee R
Full Access

Background

Greater trochanteric pain syndrome (GTPS) is a common problem affecting 10–25% of the population. Physiotherapy, anti-inflammatories, corticosteroid injections and surgery have all been described in the management of GTPS, all with limited, temporal success. Extracorporeal shockwave therapy (ESWT) has been proposed as a potential management option for this difficult presentation.

Method

We ran a prospective, 2 arm, single blinded, randomised control trial comparing focused shockwave therapy to an ultrasound guided corticosteroid injection. The primary outcome measure was the visual analogue pain score. Secondary outcome measures included the Harris hip score and Trendelenburg test for function; the SF-36 for quality of life (QoL); and a Likert scale question for a subjective assessment of symptom improvement.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1152 - 1157
1 Sep 2008
Khan M Kuiper J Richardson JB

Wear of metal-on-metal bearings causes elevated levels of cobalt and chromium in blood and body fluids. Metal-on-metal bearings have two distinct wear phases. In the early phase, the wear rate is high. Later, it decreases and the bearing enters a steady-state phase. It is expected that as the wear rates decline, the level of cobalt detected in plasma will also decrease. We studied the baseline and exercise-related cobalt rise in 21 patients (13 men and eight women) with a mean age of 54 years (38 to 80) who had undergone successful hip resurfacing at a mean of 44 months (10 to 96) earlier. Our results showed that circulating baseline cobalt levels were not significantly correlated with the time since implantation (r = 0.08, p = 0.650). By contrast, the exercise-related cobalt rise was directly correlated with the inclination angle of the acetabular component (r = 0.47, p = 0.032) and inversely correlated with the time since implantation (r = −0.5, p = 0.020).

Inclination of the acetabular component should be kept less than 40° to decrease the production of wear debris.