This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for bone tumour resection. We retrospectively reviewed 29 bone tumour resections that used 3DP-PSRGs based on 3D CT and 3D MRI. We evaluated the resection amount errors and resection margin errors relative to the preoperative plans. Guide-fitting errors and guide distortion were evaluated intraoperatively and one month postoperatively, respectively. We categorized each of these error types into three grades (grade 1, < 1 mm; grade 2, 1 to 3 mm; and grade 3, > 3 mm) to evaluate the overall accuracy.Aims
Methods
Although absorbable sutures for the repair of acute Achilles tendon rupture (ATR) have been attracting attention, the rationale for their use remains insufficient. This study prospectively compared the outcomes of absorbable and nonabsorbable sutures for the repair of acute ATR. A total of 40 patients were randomly assigned to either braided absorbable polyglactin suture or braided nonabsorbable polyethylene terephthalate suture groups. ATR was then repaired using the Krackow suture method. At three and six months after surgery, the isokinetic muscle strength of ankle plantar flexion was measured using a computer-based Cybex dynamometer. At six and 12 months after surgery, patient-reported outcomes were measured using the Achilles tendon Total Rupture Score (ATRS), visual analogue scale for pain (VAS pain), and EuroQoL five-dimension health questionnaire (EQ-5D).Aims
Methods
The prevalence of the various patterns of spinopelvic abnormalities that increase the risk for prosthetic impingement is unknown. While prior surgery or lumbar fusion are recognized as a risk factors for postoperative dislocation, many patients presenting for THA do not have obvious radiographic abnormalities. The purpose of this study is to determine the prevalence of large posterior pelvic tilt (PPT) when standing, stiff lumbar-spine (SLL) and spino-pelvic sagittal imbalance (SSI) in patients undergoing primary THA. A consecutive series of 1592 patients (56% female) over 2 years underwent functional analysis of spinopelvic mobility using CT, standing, and flexed seated lateral radiographs as part of pre-operative THA planning. The average age was 65 (20–93). We investigated the prevalence of these 3 validated spinopelvic parameters known to increase the risk for impingent and correlated them to the patient's age and gender using Chi squared analysis. Finally, the risk of flexion and extension impingement was modeled for each patient at a default supine cup orientation (DSCO) of 40°/20° (±5°).Introduction
Methods
The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) remains controversial, even though SONK usually involves only medial compartment of the knee joint. We aimed to compare the survival rate and clinical outcomes of UKA in SONK and medial compartment osteoarthritis (MOA) via a meta-analysis of previous studies. MEDLINE database in PubMed, the Embase database, and the Cochrane Library were searched up to January 2018 with keywords related to SONK and UKA. Studies were selected with predetermined inclusion criteria: (1) medial UKA as the primary procedure, (2) reporting implant survival or clinical outcomes of osteonecrosis and osteoarthritis, and (3) follow-up period greater than 1 year. Quality assessment was performed using the risk of bias assessment tool for non-randomised studies (RoBANs). A random effects model was used to estimate the pooled relative risk (RR) and standardised mean difference. The incidence of UKA revision for any reason was significantly higher in SONK than in MOA group (pooled RR = 1.83, p = 0.009). However, the risk of revision due to aseptic loosening and all- cause re-operation was not significantly different between the groups. Moreover, when stratified by the study quality, high quality studies showed similar risk of overall revision in SONK and MOA (p = 0.71). Subgroup analysis revealed worse survival of SONK, mainly related to high failure after uncemented UKA. Clinical outcomes after UKA were similar between SONK and MOA (p = 0.66). Cemented UKA has similar survival and clinical outcomes in SONK and MOA. Prospective studies designed specifically to compare the UKA outcomes in SONK and MOA are necessary.
Occasionally, patients experience new or increased ankle pain following total knee arthroplasty (TKA). The aims of this study were to determine (1) how the correction of varus malalignment of the lower limb following TKA affected changes in alignment of the ankle and hindfoot, (2) the difference in changes in alignment of the ankle and hindfoot between patients with and without ankle osteoarthritis (OA), and (3) whether the rate of ankle pain and the clinical outcome following TKA differed between the 2 groups. We retrospectively reviewed prospectively collected data of 56 patients (99 knees) treated with TKA. Among these cases, concomitant ankle OA was found in 24 ankles. Radiographic parameters of lower-limb, ankle, and hindfoot alignment were measured preoperatively and 2 years postoperatively. In addition, ankle pain and clinical outcome 2 years after TKA were compared between patients with and without ankle OA.Background
Methods
Authors sought to determine the degree of lateral condylar hypoplasia of distal femur was related to degree of valgus malalignment of lower extremity in patients who underwent TKA. Authors also examined the relationships between degree of valgus malalignment and degree of femoral anteversion or tibial torsion. This retrospective study included 211 patients (422 lower extremities). Alignment of lower extremity was determined using mechanical tibiofemoral angle (mTFA) measured from standing full-limb AP radiography. mTFA was described positive value when it was valgus. Patients were divided into three groups by mTFA; more than 3 degrees of valgus (valgus group, n = 31), between 3 degrees of valgus to 3 degrees of varus (neutral group, n = 78), and more than 3 degrees of varus (varus group, n = 313). Condylar twisting angle (CTA) was used to measure degree of the lateral femoral condylar hypoplasia. CTA was defined as the angle between clinical transepicondylar axis (TEA) and posterior condylar axis (PCA). Femoral anteversion was measured by two methods. One was the angle formed between the line intersecting femoral neck and the PCA (pFeAV). The other was the angle formed between the line intersecting femoral neck and clinical TEA (tFeAV). Tibial torsion was defined as a degree of torsion of distal tibia relative to proximal tibia. It was determined by the angle formed between the line connecting posterior cortices of proximal tibial condyles and the line connecting the most prominent points of lateral and medial malleolus. Positive values represented relative external rotation. Negative values represented relative internal rotation.Background
Methods
Recently, concerns arose over the medial tibial bone resorption of a novel cobalt-chromium (CoCr) implant. This study aimed to investigate the effects of tibial component material, design, and patient factors on periprosthetic bone resorption and to determine its association with clinical outcomes after total knee arthroplasty (TKA). A total of 462 primary TKAs using five types of implants were included. To evaluate tibial periprosthetic bone resorption, we assessed radiolucent lines (RLL) and change in bone mineral density at the medial tibial condyle (BMDMT). Factors related to bone resorption were assessed using regression analysis. Clinical outcomes were also evaluated with respect to periprosthetic bone resorption. Compared to titanium (Ti) implants, CoCr implants showed a higher incidence of complete RLL (23.1% vs. 7.9% at two years post-TKA) and a greater degree of BMDMT reduction. However, there was no significant difference between the implants made of the same material. Increased medial tibial bone resorption was associated with male sex, osteoporosis, larger preoperative varus deformity, longer follow-up period, and lower body mass index. The periprosthetic bone resorption was not associated with clinical outcomes including changes in range of motion and WOMAC score. Furthermore, no cases warranted additional surgery. Periprosthetic bone resorption was associated with implant material but not with implant design. Moreover, patient factors were related to the medial tibial bone resorption post-TKA. However, the periprosthetic bone resorption was not associated with short-term clinical outcomes. We contend that researchers should incorporate integrative considerations when developing and assessing novel implants.
We sought to determine whether there was a difference in the posterior condylar offset (PCO), posterior condylar offset ratio (PCOR) following total knee arthroplasty (TKA) with anterior referencing (AR) or posterior referencing (PR) systems. We also assessed whether the PCO and PCOR changes, as well as patient factors were related to range of motion (ROM) in each referencing system. In addition, we examined whether the improvements in clinical outcomes differed between the two referencing systems. This retrospective study included 130 consecutive patients (184 knees) with osteoarthritis who underwent primary posterior cruciate ligament (PCL)-substituting fixed-bearing TKA. All patients were categorized into the AR or PR group according to the referencing system used. Radiographic parameters, including PCO and PCOR, were measured using true lateral radiographs. The difference between preoperative and postoperative PCO and PCOR values were calculated. Clinical outcomes including ROM and Western Ontario and McMaster University (WOMAC) scores were evaluated preoperatively and at 2 years after TKA. The PCO, PCOR values, and clinical outcomes were compared between the two groups. Furthermore, multiple linear regression analysis was performed to determine the factors related to postoperative ROM in each referencing system.Purpose
Methods
Humeral retroversion is variable among individuals, and there are several measurement methods. This study was conducted to compare the concordance and reliability between the standard method and 5 other measurement methods on Twodimensional (2D) computed tomography (CT) scans. CT scans from 21 patients who underwent shoulder arthroplasty (19 women and 2 men; mean age, 70.1 years [range, 42 to 81 years]) were analyzed. The elbow transepicondylar axis was used as a distal reference. Proximal reference points included the central humeral head axis (standard method), the axis of the humeral center to 9 mm posterior to the posterior margin of the bicipital groove (method 1), the central axis of the bicipital groove –30° (method 2), the base axis of the triangular shaped metaphysis +2.5° (method 3), the distal humeral head central axis +2.4° (method 4), and contralateral humeral head retroversion (method 5). Measurements were conducted independently by two orthopedic surgeons.Background
Methods
Adjuvant treatment after intralesional curettage for atypical
cartilaginous tumours (ACTs) of long bones is widely accepted for
extending surgical margins. However, evaluating the isolated effect
of adjuvant treatment is difficult, and it is unclear whether not
using such adjuvants provides poor oncological outcomes. Hence,
we analyzed whether intralesional curettage without cryosurgery
or chemical adjuvants provides poor oncological outcomes in patients
with an ACT. A total of 24 patients (nine men, 15 women) (mean age 45 years;
18 to 62) were treated for ACTs of long bones and followed up for
a median of 66 months (interquartile range 50 to 84). All patients
were treated with extensive manual curettage and limited burring.
Bone cement and grafts were used to fill bone defects in 16 and eight
patients, respectively. No chemical adjuvants or cryosurgery were
used.Aims
Patients and Methods
This study was conducted to evaluate the cytokine-release kinetics of platelet-rich plasma (PRP) according to different activation protocols. Two manual preparation procedures (single-spin (SS) at 900 g for five minutes; double-spin (DS) at 900 g for five minutes and then 1500 g for 15 minutes) were performed for each of 14 healthy subjects. Both preparations were tested for platelet activation by one of three activation protocols: no activation, activation with calcium (Ca) only, or calcium with a low dose (50 IU per 1 ml PRP) of thrombin. Each preparation was divided into four aliquots and incubated for one hour, 24 hours, 72 hours, and seven days. The cytokine-release kinetics were evaluated by assessing PDGF, TGF, VEGF, FGF, IL-1, and MMP-9 concentrations with bead-based sandwich immunoassay.Objectives
Methods
Cancellous allograft bone chips are commonly
used in the reconstruction of defects in bone after removal of benign tumours.
We investigated the MRI features of grafted bone chips and their
change over time, and compared them with those with recurrent tumour.
We retrospectively reviewed 66 post-operative MRIs from 34 patients
who had undergone curettage and grafting with cancellous bone chips
to fill the defect after excision of a tumour. All grafts showed
consistent features at least six months after grafting: homogeneous
intermediate or low signal intensities with or without scattered
hyperintense foci (speckled hyperintensities) on T1 images; high
signal intensities with scattered hypointense foci (speckled hypointensities)
on T2 images, and peripheral rim enhancement with or without central
heterogeneous enhancements on enhanced images. Incorporation of
the graft occurred from the periphery to the centre, and was completed
within three years. Recurrent lesions consistently showed the same signal
intensities as those of pre-operative MRIs of the primary lesions.
There were four misdiagnoses, three of which were chondroid tumours. We identified typical MRI features and clarified the incorporation
process of grafted cancellous allograft bone chips. The most important
characteristics of recurrent tumours were that they showed the same
signal intensities as the primary tumours. It might sometimes be
difficult to differentiate grafted cancellous allograft bone chips
from a recurrent chondroid tumour. Cite this article:
Achieving durable implant–host bone fixation is the major challenge in uncemented revision hip arthroplasty when significant bone stock deficiencies are encountered. The purpose of this study was to develop an experimental model which would simulate the clinical revision hip scenario and to determine the effects of alendronate coating on porous tantalum on gap filling and bone ingrowth in the experimental model. Thirty-six porous tantalum plugs were implanted into the distal femur, bilaterally of 18 rabbits for four weeks. There were 3 groups of plugs inserted; control groups of porous tantalum plugs (Ta) with no coating, a 2nd control group of porous tantalum plugs with micro-porous calcium phosphate coating, (Ta-CaP) and porous tantalum plugs coated with alendronate (Ta-CaP-ALN). Subcutaneous fluorochrome labelling was used to track new bone formation. Bone formation was analysed by backscattered electron microscopy and fluorescence microscopy on undecalcified histological sections.Introduction
Methods
to develop an experimental model which would simulate the clinical revision hip scenario and determine the effects of alendronate coating on porous tantalum on gap filling and bone ingrowth in the experimental model.
We describe a successful modified operative procedure at an average 19 months follow-up in 3 patients with congenital dislocation of the patella and compare its merits to the other procedures already reported in the literature. Congenital dislocation of the patella may be associated with other congenital conditions or syndromes i.e. Down’s syndrome, congenital vertical talus and cerebral palsy. Numerous operative techniques have been described in the literature which may be divided into 3 basic groups. A modification of the Langenskiold &
Ritsila procedure is described. The original procedure describes an extensive lateral release with detachment and medial transfer of the patellar tendon through a curved incision. The tendon is routed through a fold of synovium medially and fixed distally to bone with sutures through drill holes in the proximal tibia. We found at surgery this synovium was too fragile to hold the transferred tendon and the use of drill holes unnecessary. The main alterations include a limited and straight anterior skin incision, a fashioning of a ‘buckle’ of the transferred distal patellar tendon to a distally based flap which avoids drill holes in the growing bone. This modification of the Langenskiold procedure was used successfully in 3 cases, including a revision of a failed Goldthwaite- Roux procedure in a mentally handicapped child. The results at average 19 months follow-up are successful. The early results confirm that the patella remains located and tracks normally. The valgus and flexion deformities have significantly improved. This modification of the Langenskiold &
Ritsila procedure requires less dissection than other operations, with no bony surgery and a cosmetic scar. The Langen-skiold &
Ritsila procedure has been successful and we feel that this modification simplifies and improves on the original technique.
The purpose of this study was to investigate the effects of varying tire pressures on rolling resistance of pneumatic wheelchair tires and compare the rolling resistance of pneumatic versus solid wheelchair tires. Our study demonstrated that, statistically significant increases in rolling resistance occurred at and below 50% of the recommended tire pressures (RTP) for the pneumatic tires tested. Also, solid tires performed worse than pneumatic tires at 25% (RTP). Shoulder pain among the spinal cord injured wheelchair users is reported between 60–100%. Despite the shoulder problems, it’s not uncommon to see WC users with low or flat tires. To reduce the need for regular inflating of tires, people have switched to the popular solid tire. Unfortunately, based on our results, the use of the popular solid tires may still contribute to repetitive strain disorders in wheelchair users. Compared to the recommended tire pressures the pneumatic tires showed statistically significant decreases in rolling distance at 25% and 50% RTP. The rolling distances of the two solid tires performed similarly to 25% RTP of the pneumatic tires. This prospective study measured the differences in rolling resistance of five types of commonly used wheelchair tires (three pneumatic: two solid: under four different tire pressures (100%, 75%, 50% and 25% RTP) using a standardized roll down test ramp and a wheelchair with a 56 kg load. Four samples of rolling distances (five per tire pressure per sample) were measured for each tire type and analyzed (repeated measure ANOVA).