Understanding lumbar facet joint involvement and biomechanical changes post spinal fusion is limited. This study aimed to establish an in vitro model assessing mechanical effects of fusion on human lumbar facet joints, employing synchronized motion, pressure, and stiffness analysis. Seven human lumbar spinal units (age 54 to 92, ethics 15/YH/0096) underwent fusion via a partial nucleotomy model mimicking a lateral cage approach with PMMA cement injection. Mechanical testing pre and post-fusion included measuring compressive displacement and load, local motion capture, and pressure mapping at the facet joints. pQCT imaging (82 microns isotropic) was carried out at each stage to assess the integrity of the vertebral endplates and quantify the amount of cement injected. Before fusion, relative facet joint displacement (6.5 ± 4.1 mm) at maximum load (1.1 kN) exceeded crosshead displacement (3.9 ± 1.5 mm), with loads transferred across both facet joints. After fusion, facet displacement (2.0 ± 1.2 mm) reduced compared to pre-fusion, as was the crosshead displacement (2.2 ± 0.6 mm). Post-fusion loads (71.4 ± 73.2 N) transferred were reduced compared to pre-fusion levels (194.5 ± 125.4 N). Analysis of CT images showed no endplate damage post-fusion, whilst the IVD tissue: cement volume ratio did not correlate with the post-fusion behaviour of the specimens.Objectives
Methods and Results
Osteoporosis can cause significant disability and cost to health services globally. We aim to compare risk fractures for both osteoporosis and fractures at the L1-L4 vertebrae (LV) and the neck of femurs (NOFs) in patients referred for DEXA scan in the North-West of England. Data was obtained from 31546 patients referred for DEXA scan in the North-West of England between 2004 and 2011. Demographic data was retrospectively analysed using STATA, utilising chi-squared and t-tests. Logistical models were used to report odds ratios for risk factors included in the FRAX tool looking for differences between osteoporosis and fracture risk at the LV and NOFs. In a study involving 2530 cases of LV fractures and 1363 of NOF fractures, age was significantly linked to fractures and osteoporosis at both sites, with a higher risk of osteoporosis at NOFs compared to LV. Height provided protection against fractures and osteoporosis at both sites, with a more pronounced protective effect against osteoporosis at NOFs. Weight was more protective for NOF fractures, while smoking increased osteoporosis risk with no site-specific difference. Steroids were unexpectedly protective for fractures at both sites, with no significant difference, while alcohol consumption was protective against osteoporosis at both sites and associated with increased LV fracture risk. Rheumatoid arthritis increased osteoporosis risk in NOFs and implied a higher fracture risk, though not statistically significant compared to LV. Results summarised in Table 1. Our study reveals that established osteoporosis and fracture risk factors impact distinct bony sites differently. Age and rheumatoid arthritis increase osteoporosis risk more at NOFs than LV, while height and steroids provide greater protection at NOFs. Height significantly protects LV fractures, with alcohol predicting them. Further research is needed to explore risk factors’ impact on additional bony sites and understand the observed differences’ pathophysiology. For any figures or tables, please contact the authors directly.
Up to 19% of patients who undergo surgery for an acute hip fracture are readmitted to the hospital within three months of the index operation. We aimed to identify risk factors for unplanned clinic attendance, readmission, and mortality within the first 12 months postoperatively and subsequently determine if there is a role for routine follow-up. Patients greater than 65 years old who underwent hip hemiarthroplasty using an uncemented Thompson implant for treatment of a traumatic non-pathological hip fracture were identified from a prospectively maintained database at a single institution between August 2007 and February 2011. Patient demographics, comorbidities, place of residence, mobility status, unplanned attendance to an orthopaedic clinic with symptoms relating to the respective limb, readmission, and mortality were recorded.Abstract
Objectives
Methods
Iliopsoas pathology is a relatively uncommon cause of pain following total hip arthroplasty (THA), typically presenting with symptoms of groin pain on active flexion and/or extension of the hip. A variety of conservative and surgical treatment options have been reported. In this retrospective cohort study, we report the incidence of iliopsoas pathology and treatment outcomes. A retrospective review of 1,000 patients who underwent THA over a five-year period was conducted, to determine the incidence of patients diagnosed with iliopsoas pathology. Outcome following non-surgical and surgical management was assessed.Aims
Methods
Hip fractures in young adults are rare but represent an important cohort of patients, of which relatively limited data exists. The aim of this study was to evaluate this distinct subgroup of hip fractures from an epidemiological perspective and assess their subsequent outcomes. Patients aged 18–50 were identified across an 8 year period from a total of 5326 hip fractures. 46 hip fractures met the inclusion criteria and a retrospective case series analysis was conducted. 25/46 (54%) of fractures were intracapsular and 21/46 (46%) were extracapsular. Only 15/46 (33%) of fractures were sustained from a high energy mechanism and 31/46 (67%) low energy. The low energy cohort was significantly more comorbid with a mean Elixhauser comorbidity score of 1.5 compared to the high energy cohort 0.3 (p<0.0005, unpaired t-test). Alcohol excess was the most prevalent comorbidity present in 24% of patients and was a positive predictor in complication (p=0.006, binary regression). Failure of fixation (non-union/avascular necrosis) in displaced intracapsular fractures sustained following low energy trauma managed by internal fixation 5/11 (45%) was markedly higher than the high energy cohort 0/6 (0%). 5 year mortality was 9% for all hip fractures, six times higher than an aged matched cohort of non-hip fractures (p=0.007, Wilcoxon test). Representing only 0.86% of all hip fractures in the study period, hip fractures in young adults are rare. A clear sub-division of patients is observed between patients with a low and high energy mechanism, both in terms of level of comorbidity and surgical outcome.
We evaluated an operative technique, described
by the Exeter Hip Unit, to assist accurate introduction of the femoral
component. We assessed whether it led to a reduction in the rate
of leg-length discrepancy after total hip arthroplasty (THA). A total of 100 patients undergoing THA were studied retrospectively;
50 were undertaken using the test method and 50 using conventional
methods as a control group. The groups were matched with respect
to patient demographics and the grade of surgeon. Three observers
measured the depth of placement of the femoral component on post-operative
radiographs and measured the length of the legs. There was a strong correlation between the depth of insertion
of the femoral component and the templated depth in the test group
(R = 0.92), suggesting accuracy of the technique. The mean leg-length
discrepancy was 5.1 mm (0.6 to 21.4) pre-operatively and 1.3 mm
(0.2 to 9.3) post-operatively. There was no difference between Consultants
and Registrars as primary surgeons. Agreement between the templated
and post-operative depth of insertion was associated with reduced
post-operative leg-length discrepancy. The intra-class coefficient
was R ≥ 0.88 for all measurements, indicating high observer agreement.
The post-operative leg-length discrepancy was significantly lower
in the test group (1.3 mm) compared with the control group (6.3
mm, p <
0.001). The Exeter technique is reproducible and leads to a lower incidence
of leg-length discrepancy after THA. Cite this article:
The aim of our study was to assess the outcome of caudal epidural injection for patients with low back pain in relation to fatty infiltration of spinal muscle. This is a prospective study. The spinal muscles were graded on sagittal section T1 MRI at the lower border of lumber 4 vertebra from 3 to 12 depending on the severity of fatty infiltration. The outcome of the intervention was assessed by improvement in pre and post intervention oswestry disability index score as well as visual analog pain score. Patients with significant fatty changes don't respond well to the caudal epidural injection.
Early stabilization has the potential to expedite early return to function and reduce hospital stay thus reducing cost to health care. A clinical audit was performed to test the hypothesis that early surgical stabilization lowers the rate of soft tissue complications and is not influenced by choice of distal fibular implants used for stabilization of ankle fractures. All surgically treated adult patients with isolated unstable ankle fracture were included from April 2012 to April 2013 at a MTC in UK. Patients with poly-trauma were excluded. All patients underwent a standard surgical protocol: aim for early definitive surgical fixation (ORIF) within 24 hours however if significantly swollen than temporary stabilization with an external fixation followed by a staged definitive fixation.Introduction:
Methods:
The ideal treatment for traumatic anterior dislocation
of the shoulder in the skeletally immature patient is controversial.
The aim of this study is to evaluate the outcomes after either conservative
and/or surgical treatment using the Latarjet technique. A retrospective
series of 49 out of 80 patients were reviewed. We found no significant differences
between either treatment method regarding functional scores and
pain levels. Although not statistically significant, post-surgical
patients showed better signs of shoulder stability than others who
have a higher rate of recurrence. Further, 92% of the post-surgical
group had returned to the same level of activity Cite this article:
There has been a recent surge in the interest of the role of vitamin D in chronic musculoskeletal pain however there are limited studies that have investigated the link of vitamin D hypovitaminosis with low back pain. The aim of our study was to determine the prevalence of low vitamin D levels in patients who present with low back pain in an outpatient setting in the UK. Data was collected retrospectively from computerised databases of all patients who presented with low back pain from a single spinal consultant's outpatient clinic and have had serum levels of 25-hydroxycholecalciferol (25-OH vitamin D) requested. Data of these patients were collected from hospital electronic and paper records and analysed against their serum 25-OH vitamin D levels.Introduction
Methods
Leg length discrepancy (LLD) can adversely affect functional outcome and patient satisfaction after total hip arthroplasty. We describe a novel intraoperative technique for femoral component insertion. We aimed to determine if this technique resulted in the desired femoral placement, as templated, and if this was associated with a reduced LLD. A series of fifty consecutive primary total hip replacements were studied. Preoperative digital templating was performed on standardised PA radiographs of the hips by the senior surgeon. The preoperative LLD was calculated and the distance from the superior tip of the greater trochanter to the predicted shoulder of the stem was calculated (GT-S). Intraoperatively, this length was marked on the rasp handle and the stem inserted to the predetermined level by the surgeon. This level corresponded to the tip of the greater trochanter and formed a continuous line to the mark on the rasp handle. Three independent blinded observers measured the GT-S on the postoperative radiographs. We assessed the relationship between the senior author's GT-S (preoperative) and the observers' GT-S (postoperative) using a Person correlation. The observers also measured the preoperative and postoperative LLD, and the inter-observer variability was calculated as the intra-class correlation coefficient. There was a strong correlation of preoperative and postoperative GT-S (R=0.87), suggesting that the stem was inserted as planned. The mean preoperative and postoperative LLD were −4.3 mm (−21.4–4) and −0.9 mm (−9.8–8.6), respectively (p<0.001). This technique consistently minimised LLD in this series. This technique is quick, non-invasive and does not require supplementary equipment.
The advantages of metal on metal (MOM) hip replacement are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri prosthetic osteolysis generated as a result of a biological response to particulate wear debris. Our aim in this study was to determine whether a steeply inclined acetabular component would give rise to a higher concentration of metal ions. Between April 2003 and June 2006, 22 patients had MOM hip replacement for osteoarthritis by a single Surgeon. There were 12 male and 10 female patients. The average age at the time of surgery was 56 years (Range: 44–69 years). We divided the 22 patients into 2 groups, one group (A) of 11 patients with the acetabular inclination angle more than 50 degrees and the other group (B) of 11 patients with the angle less than 50 degrees. The inclination of the acetabular cup was measured using a standard AP radiograph of the pelvis. The patients had metal ion levels (blood chromium and serum cobalt) measured at an average follow up of 3.2 years (Range 2.4 to 5 years).Introduction
Patients and methods
The advantages of large diameter metal on metal total hip arthroplasty (MoM THA) and hip resurfacing arthroplasty are decreased wear rate, preservation of bone stock, anatomical restoration and enhanced stability. Large amounts of metal wear particles and metal ions are released which may induce adverse reactions including local soft tissue toxicity, hypersensitivity reactions, bone loss and risk of carcinogenesis. Aseptic loosening can be the result of a peri-prosthetic osteolysis generated as a result of a biological response to particulate wear debris. No reports in the literature exist as to whether circulating levels of Chromium (Cr) and Cobalt (Co) decrease upon removal of a symptomatic large diameter MoM implant or whether levels remain high due to the effect of metal ions debris left behind in the soft tissues after revision surgery. Between June 2006 and June 2009 we undertook 44 revision surgeries of both large head MoM THAs (femoral head diameter 38mm) and metal-on-metal hip resurfacings for suspected metallosis. Mean time from original implant to revision was 4 years, 8 months (1yr 4mo–7yr 9mo). The mean follow up evaluation was 2 years and 2 months (1yr 2mo–4 years). Blood samples were taken for whole blood Cr and serum Co according to a recognised protocol and compared with reference levels indicated by the Medicines and Healthcare Regulatory Agency recommendation of less than 7ppb for Cr (130nM/L) and Co (119nM/L).INTRODUCTION
PATIENTS AND METHODS
Bioreactors used in tissue engineering are mostly batch-fed with media added and removed periodically. Continuous flow bioreactors help increase ECM accumulation and cell proliferation, due to continuous flow of fresh media, thus, maintaining a steady extracellular nutrient environment. In previous work, we found chondrocytes cultured in continuous flow bioreactors with 20mM HEPES, accumulated considerably more matrix than static cultures. Hence, the objective of this study is to determine if NaHCO3 helps maintain a more physiological extracellular pH in the bioreactor, thus, enhancing ECM accumulation. Cartilaginous tissue constructs were generated from isolated chondrocytes harvested from the metacarpal joints of 12-18 month old calves. Cells were seeded in high-density 3D cultures (2 million cells/construct). Constructs were cultivated in a continuous flow bioreactor, with and without 14 mM NaHCO3 supplemented media, for 5 weeks, at 37 degrees Celsius, 95% relative humidity and 5% CO2. After 5 weeks of culture the tissue weight, thickness, pH and ECM deposition were determined. From the results obtained (Table 1), it is evident that chondrocytes cultured in the continuous flow bioreactor with 14mM NaHCO3 and 20mM HEPES, proliferated more extensively and produced more ECM than chondrocytes cultured in only 20mM HEPES. Additionally, the NaHCO3 constructs accumulated ECM in both the vertical (thickness) and horizontal (outgrowth) planes. The question then arises, are the effects mediated by improved buffering, or by addition of NaHCO3 itself. There was a significant difference between the pH of media with (pH 7.41) and without NaHCO3 (pH 6.95) supplementation, with no exposure to cells or tissue; when allowed to equilibrate with 5% CO2 at 37 degrees Celsius. However, there was little difference between the media after exposure to cells; after five weeks of culture in the bioreactor (Table 1). Thus, in the bioreactor with bicarbonate present, because of increased cell number and activity, the pH fell 0.54 pH units during the 7 hour residence time in comparison to the bioreactor with no bicarbonate supplementation. With no NaHCO3 supplementation, the extracellular pH of the medium fed to the cells was never above pH 7.0 (Table 1); low pH could account, at least in part, for lower ECM and cell numbers.
In revision hip surgery, Type IIIB femurs have presented the greatest historical challenge to achieving stable fixation and osseous integration. This study evaluated the intermediate term outcome of a modular, tapered, distal fixation revision femoral component used in a consecutive revision hip series with special attention to its performance in the defective Type IIIB femur. Between February 2002 and January 2005, 51 consecutive revision hip arthroplasties were performed using modular, tapered, distal fixation femoral components. The femoral defects at the time of revision surgery were classified using a system previously described by Paprosky. The most recent radiographs were reviewed and clinic notes examined to assess femoral component stability.Purpose
Methods
Patients with peripheral primary bone tumours are often identified and referred at an early stage to a regional tumour service according to established guidelines. In patients with primary bone tumours of the spine, however, the definitive management or outcome of such patients is being prejudiced by preliminary intervention from non-specialist services prior to their referral. Objective: To audit the standards of management of patients with primary bone tumours of the spine referred to a regional tumour service. Retrospective review of case notes and radiology. Subjects: Patients with primary bone tumour of the spine managed at the Orthopaedic Spine Unit with the Regional Bone Tumour Service in Newcastle Upon Tyne Hospitals NHS Trust. Referral to tumour service, prior intervention, operative treatment, survival, factors affecting definitive management 31 of 39 (16 benign, 23 malignant) patients were initially referred from primary care to services These tumours present complex issues regarding their definitive management to optimise outcome. Closer links between departments are required to enable the multidisciplinary management of primary bone tumours of the spine. Prior surgical intervention may compromise cure. Those involved in their management should be encouraged to liaise with their regional bone tumour service to improve outcome.
The mean age of the patients was 11.04 years (range between 4–16). Mean follow up time for the patients after they had undergone the procedure was 16.2 months (range 3 – 34). The Mean correction achieved − 21.52 degrees (range 5 – 40). Mean correction per month − 2.05 degrees. A paired ‘t’ test showed the correction was found to be highly statistically significant (p value <
0.001).