Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 42 - 42
1 Nov 2022
Kumar K Van Damme F Audenaert E Khanduja V Malviya A
Full Access

Abstract

Introduction

Recurrent groin pain following periacetabular osteotomy (PAO) is a challenging problem. The purpose of our study was to evaluate the position and dynamics of the psoas tendon as a potential cause for recurrent groin pain following PAO.

Methods

Patients with recurrent groin pain following PAO were identified from a single surgeon series. A total of 13 patients with 18 hips (4.7%) out of a 386 PAO, had recurrent groin pain. Muscle path of the psoas tendon was accurately represented using 3D models from CT data were created with Mimics software. A validated discrete element model using rigid body springs was used to predict psoas tendon movement during hip circumduction and walking.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 41 - 41
1 Nov 2022
Kumar K Holleyman R Khanduja V Malviya A
Full Access

Abstract

Introduction

The extent to which hip arthroscopy (HA) treatments influence sexual function is not well described and limited to small cohorts. This study aims to describe trends in self-reported reported sexual function before and after HA.

Methods

Adult (≥18 years) patients who underwent HA between 1/01/2012 and 31/10/2020 were extracted from the UK Non-Arthroplasty Hip Registry. International Hip Outcome Tool 12 (iHOT-12) questionnaires were collected pre-operatively and at 6 and 12 months. The iHOT-12 then asks asking patients to quantify ‘how much trouble they experience with sexual activity because of their hip?’ with responses converted to a continuous scale (0–100) to measure function.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 5 - 5
1 Nov 2022
Bidwai R Goel A Khan K Cairns D Barker S Kumar K Singh V
Full Access

Abstract

Aim

Excessive glenoid retroversion and posterior wear leads to technical challenges when performing anatomic shoulder replacement. Various techniques have been described to correct glenoid version, including eccentric reaming, bone graft, posterior augmentation and custom prosthesis. Clinical outcomes and survivorship of a Stemless humeral component with cemented pegged polyethylene glenoid with eccentric reaming to partially correct retroversion are presented.

Patients and Methods

Between 2010– 2019, 115 Mathys Affinis Stemless Shoulder Replacements were performed. 50 patients with significant posterior wear and retroversion (Walch type B1, B2, B3 and C) were identified. Measurement of Pre-operative glenoid retroversion and Glenoid component version on a post op axillary view was performed by method as described by Matsen FA. Relative correction was correlated with clinical and radiological outcome.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 2 - 2
1 Apr 2013
Ramesh K Barker S Kumar K
Full Access

Objective

The purpose of this study was to compare outcome of arthroscopic stabilization of the shoulder using knotted and knotless anchors and two rehabilitation regimes.

Method

This is a retrospective study of 58 patients who underwent arthroscopic shoulder stabilization over a five year period (2005–2009). There were two groups of patients. In group A stabilization was performed using absorbable anchors with a knotted technique using No.1 PDS suture. This group had an early mobilization regime. In group B a knotless anchor technique was used with PEEK anchors and nonabsorbable sutures. The patients in this group were immobilised in a sling for 6 weeks. There were a total of 58 patients, 37 in group A and 21 in group B. The mean age of patients undergoing the procedure was 35.7. There were a total of 23 males and 14 females in group A and 15 males and 6 females in group B. The number of dislocations prior to surgery ranged from 0 to multiple times a day. Patients had a mean follow up of 5 years (three to seven years - 2005 to 2009) and subjective shoulder function was evaluated using Oxford instability score and self-assessment questionnaire.