Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 11 - 11
1 Aug 2020
Selley R Butler B Hartwell M Johnson D Terry M Tjong V
Full Access

Orthopaedic surgeons frequently use opioids for peri-operative pain management and there is considerable variability in the amount prescribed between surgeons. As such, the appropriate number of opioids to prescribe for specific procedures is often unknown. Leftover prescription opioids are at risk for diversion to family and friends for nonmedical use. The aim of this study was to determine the optimal amount of narcotics to prescribe postoperatively for patients undergoing hip arthroscopy.

23 consecutive patients were enrolled. All patients were prescribed 60 tablets of hydrocodone/acetaminophen 10/325 postoperatively as part of a multimodal pain management strategy. Patients were called at 14 and 21 days post-operatively to tabulate the number of pills used and knowledge of how to properly dispose of pills.

The median number of narcotic pain pills required was 6 (IQR: 3,15). Over half of patients (56.5%) required ≤10 narcotic pain pills postoperatively. A large number of narcotic tablets (1071/1380, 77.6%) were unused and a small percentage of patients (8/23, 34.8%) were aware of proper disposal techniques. Knowledge of how to properly dispose of unused narcotics was protective against a prolonged duration of narcotic use postoperatively (Parameter estimate −5.7, 95% CI: −11.3, −0.1, p = 0.045).

Reducing the number of prescribed narcotic tablets to 25 would meet the post-operative pain demands of over 85% of hip arthroscopy patients. More judicious post-operative prescribing patterns and patient education regarding disposal may help minimize physician contribution to opioid misuse, overuse and diversion.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 21 - 21
1 Jul 2020
Hartwell M Nelson P Johnson D Nicolay R Christian R Selley R Tjong V Terry M
Full Access

Recent studies have described safe outcomes for short-stays in the hospital after total shoulder arthroplasty. The purpose of this study is to identify pre-operative and operative risk factors for hospital admissions exceeding 24 hours.

The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database was queried from 2006 to 2016 for the current procedural terminology (CPT) billing code related to total shoulder arthroplasty. Patients were then grouped as either having a length of stay (LOS) equal to or less than 24 hours or greater than 24 hours. Patients admitted to the hospital prior to the day of surgery were excluded. Patient demographics, co-morbidities, and operative time were then analyzed as risk factors for a hospital stay exceeding 24 hours. Pre-operative co-morbidities included body mass index (BMI), diabetes, smoking, chronic obstructive pulmonary disease (COPD), congestive heart failure (CHF), hypertension, dialysis, chronic steroid or immunosuppressant use, bleeding disorders, and American Society of Anesthesiologists (ASA) Classification. Univariate and multivariate analyses were then performed to identify risk factors associated with 30-day readmission.

14,339 patients met inclusion criteria and 6,507 (45.3%) had a hospital LOS less than or equal to 24 hours. The mean length of hospitalization was 1.95 ± 1.88 days, the average age was 69 ± 9.7 years old, and 56.9% of the patients were female. Following a risk adjusted multivariate analysis, increasing age (odds ratio [OR], 1.03, 95% confidence interval [CI], 1.02–1.03), ASA classification (OR, 1.50, 95% CI, 1.41–1.60), diabetes (OR, 1.69, 95% CI, 1.43–1.99), COPD (OR, 1.35, 95% CI, 1.16–1.57), CHF (OR, 2.67, 95% CI, 1.34–5.33), dialysis (OR, 2.47, 95% CI, 1.28, 4.77), history of a bleeding disorder (OR, 1.50, 95% CI, 1.20–1.88), or increasing operative time (OR, 1.01, 95% CI, 1.01–1.01) were identified as independent risk factors for hospital lengths of stay exceeding 24 hours. Male gender was identified as a protective factor for prolonged hospitalization (OR, 0.50, 95% CI, 0.46–0.53).

This study identifies patient demographics, co-morbidities, and operative-relative risk factors that are associated with increased risk for a prolonged hospitalization following total shoulder arthroplasty. Female gender, increasing age, ASA classification, operative time, or a history of diabetes, COPD, CHF, or history of a bleeding disorder are risk factors hospitalizations exceeding 24 hours.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 72 - 72
1 Jul 2020
Nicolay R Selley R Johnson D Terry M Tjong V
Full Access

Malnutrition is an important consideration during the perioperative period and albumin is the most common laboratory surrogate for nutritional status. The purpose of this study is to identify if preoperative serum albumin measurements are predictive of infection following arthroscopic procedures.

Patients undergoing knee, shoulder or hip arthroscopy between 2006–2016 were identified in the American College of Surgeons National Surgical Quality Improvement Program database. Patients with an arthroscopic current procedural terminology code and a preoperative serum albumin measurement were included. Patients with a history of prior infection, including a non-clean wound class, pre-existing wound infection or systemic sepsis were excluded. Independent t-tests where used to compare albumin values in patients with and without the occurrence of a postoperative infection. Pre-operative albumin levels were subsequently evaluated as predictors of infection with logistic regression models.

There were 31,906 patients who met the inclusion criteria. The average age was 55.7 years (standard deviation (SD) 14.62) and average BMI was 31.7 (SD 7.21). The most prevalent comorbidities were hypertension (49.2%), diabetes (18.4%) and smoking history (16.9%). The average preoperative albumin was 4.18 (SD 0.42). There were 45 cases of superficial infection (0.14%), 10 cases of wound dehiscence (0.03%), 17 cases of deep infection (0.05%), 27 cases of septic arthritis or other organ space infection (0.08%) and 95 cases of any infection (0.30%). The preoperative albumin levels for patients who developed septic arthritis (mean difference (MD) 0.20, 95% CI, 0.038, 0.35, P = 0.015) or any infection (MD 0.14, 95% CI 0.05, 0.22, P = 0.002) were significantly lower than the normal population. Additionally, disseminated cancer, Hispanic race, inpatient status and smoking history were significant independent risk factors for infection, while female sex and increasing albumin were protective towards developing any infection. Rates of all infections were found to increase exponentially with decreasing albumin. The relative risk of infection with an albumin of 2 was 3.46 (95% CI, 2.74–4.38) when compared to a normal albumin of 4. For each albumin increase of 0.69, the odds of developing any infection decreases by a factor of 0.52.

This study suggests that preoperative serum albumin is an independent predictor of septic arthritis and all infection following elective arthroscopic procedures. Although the effect of albumin on infection is modest, malnutrition may represent a modifiable risk factor with regard to preventing infection following arthroscopy.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 22 - 22
1 May 2016
Gao B Angibaud L Johnson D
Full Access

Introduction

Patellofemoral joint is an important aspect of the tri-compartmental knee joint complex. Total knee arthroplasty (TKA) replaces the articulating surfaces of distal femur and proximal tibia, and often times the patella as well. Understanding the size relationship between the femur and patella bones can provide valuable information for new prosthesis design and biomechanical analysis. However, taking anthropometric measurements on a large population of patients or even cadaveric specimens could be a challenge. As a result, there are currently little quantitative data existing in the literature regarding the size relationship between TKA patient's femur and patella. This study attempted to attack this question using a novel statistical approach and a large TKA patient database.

Methods

A multi-site clinical database operated by Exactech was used in this study. The database contains patient information of Optetrak TKA implant recipients from over 30 physicians in US, UK, and Colombia since 1995. Nine femoral implant sizes (0, 1, 2, 2.5, 3, 3.5, 4, 5 and 6) and six patellar implant sizes (26, 29, 32, 35, 38, 41 mm) were seen in these patients. Due to the low usage, femoral sizes 0 and 6 were excluded from this analysis. Taking primary TKA only, a total of 2,698 cases were included in this study. The size relationship between femoral implant and patellar implant was analyzed in this patient population. Gender effect was also examined.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 7 - 7
1 May 2016
Roche C Simovitch R Flurin P Wright T Johnson D Najmabadi Y Zuckerman J
Full Access

Introduction

A better understanding of the rate of improvement associated with aTSA and rTSA is critical to establish accurate patient expectations for treatment to reduce pain and restore function; more realistic patient expectations pre-operatively may lead to greater patient satisfaction post-operatively. To this end, this study quantifies the rate of improvement in outcomes of aTSA and rTSA using 5 different scoring metrics for 1641 patients with one platform shoulder arthroplasty system.

Methods

1641 patients (mean age: 69.3yrs) were treated by 14 orthopaedic surgeons using one platform shoulder system (Exactech, Inc). 729 patients received aTSA (65.3yrs; 384F/345M) for treatment of degenerative arthritis and 912 patients received rTSA (72.5yrs; 593F/319M) for treatment of CTA/RCT/OA. Each patient was scored pre-operatively and at various follow-up intervals (3 months, 6months, annually, etc) using the SST, UCLA, ASES, Constant, and SPADI metrics; active abduction, active forward flexion, and active/passive external rotation were also measured. 4439 total follow-up reports were analyzed (1851 and 2588 rTSA). Improvements in outcome using each metric score were calculated and normalized on a 100 point scale. The rate of improvement was analyzed using a 40 point moving filter treadline and with a 3rd order polynomial treadline over the entire range of follow-up.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 148 - 148
1 Jan 2016
Gao B Angibaud L Johnson D
Full Access

Introduction

Total knee arthroplasty (TKA) implant systems offer a range of sizes for orthopaedic surgeons to best mimic the patient's anatomy and restore joint function. From a biomechanical perspective, the challenge on the TKA implants is affected by two factors: design geometry and in vivo load. Larger geometry typically means more robust mechanical structure, while higher in vivo load means greater burden on the artificial joint. For an implant system, prosthesis geometry is largely correlated with implant size, while in vivo load is affected by the patient's demographics such as weight and height. Understanding the relationships between implant size and patients' demographics can provide useful information for new prosthesis design, implant test planning, and clinical data interpretation. Utilizing a manufacturer supported clinical database, this study examined the relationships between TKA patient's body weight, height, and body mass index (BMI) and the received implant size of a well-established implant system.

Methods

A multi-site clinical database operated by Exactech, Inc. (Gainesville, FL, USA) was utilized for this study. The database contains patient information of Optetrak TKA implant recipients from over 30 physicians in US, UK, and Colombia since 1995. Nine implant sizes (0, 1, 2, 2.5, 3, 3.5, 4, 5 and 6) are seen in the database, while size 0 was excluded due to very low usage. Taking primary TKA only, a total of 2,713 cases were examined for patient's body weight, height, BMI, and their relationships with the implant size.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 147 - 147
1 Jan 2016
Gao B Angibaud L Johnson D
Full Access

Introduction

Cruciate Retaining (CR) and Posterior Stabilizing (PS) are two common types of total knee arthroplasty (TKA) surgeries. The CR approach preserves the posterior cruciate ligament (PCL) while the PS approach sacrifices it. Implant size selection during a TKA surgery is primarily driven by the patient's bone size, but could also be affected by surgery types due to the influence of the PCL. The objective of this study was to investigate the effect of TKA surgery type on implant size selection, based on the clinical database of a well-established commercial implant system.

Methods

A clinical database operated by Exactech, Inc. (Gainesville, FL, USA) was utilized for this study. The database contains TKA patient information of Optetrak® implant recipients from over 30 physicians in the US, UK, and Colombia since 1995. Patient height was used as a control factor for comparison of surgery types, and categorized by every 10 cm (e.g., the “170 cm” category contains patients from 170 to 179 cm). Taking primary TKA only and body heights from 130 cm to 199 cm, a total of 2,677 cases were examined. No statistical difference exists on patients' gender, body weight, or BMI within every height category between the CR and PS groups. The femoral implant size and tibial insert thickness were compared between the two groups.