Dynamic stabilisation system for the spine relies on titanium screw purchase within the pedicle. Decision on osteointegration is important especially when the patient becomes symptomatic following initial good outcome. From our cohort of 420 Dynesys patients, over all incidence of screw loosening was 17%. Only 35% were symptomatic.
Seven observers composed of two expert orthopaedic spine consultant surgeons and one spine expert consultant radiologist and four Specialist Registrars in orthopaedics and radiology. Data gathered were distributed and presented in tables in the form of descriptive statistics. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. For continuous variables comparison, the t test was employed, with a significance level of 0.05.
We are planning to evaluate a 3D computer reconstruction model based on 2 X-ray views at 45 degree angle to each other which might be sensitive to detect screw loosening.
Dynamic stabilisation system for the spine relies on titanium screw purchase within the pedicle. Decision on osteointegration is important especially when the patient becomes symptomatic following initial good outcome. From our cohort of 420 Dynesys patients, over all incidence of screw loosening was 17%. Only 35% were symptomatic.
Seven observers composed of two expert orthopaedic spine consultant surgeons and one spine expert consultant radiologist and four Specialist Registrars in orthopaedics and radiology. Data gathered were distributed and presented in tables in the form of descriptive statistics. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. For continuous variables comparison, the t test was employed, with a significance level of 0.05.
We are planning to evaluate a 3D computer reconstruction model based on 2 X-ray views at 45 degree angle to each other which might be sensitive to detect screw loosening.
Outcome assessment revealed significant improvement in SF36 even after removal of stabilising system while no worsening of ODI or VAS in comparison with preoperative status.
Outcome assessment revealed significant improvement in SF36 even after removal of stabilising system while no worsening of ODI or VAS in comparison with preoperative status.