To compare the rates of sagittal and coronal correction for all-pedicle screw instrumentation and hybrid instrumentation using sublaminar bands in the treatment of thoracic adolescent idiopathic scoliosis (AIS). We retrospectively reviewed the medical records of 124 patients who had undergone surgery in two centres for the correction of Lenke 1 or 2 AIS. Radiological evaluation was carried out preoperatively, in the early postoperative phase, and at two-year follow-up. Parameters measured included coronal Cobb angles and thoracic kyphosis. Postoperative alignment was compared after matching the cohorts by preoperative coronal Cobb angle, thoracic kyphosis, lumbar lordosis, and pelvic incidence.Aims
Methods
A single operation was performed in 60 patients using a combined anterior and posterior approach and convex posterior CD baby instrumentation. Nine patients underwent two operations one week apart. All patients wore a corset brace for six months.
Compensating curvature: the mean Cobbe angle was 21° preoperatively and 12° at last follow-up. Complications: partial deficit of the anterior tibialis (n=1), nonunion (n=3), infection (n=1), disassembly (n=3), valgum tibia at the site of the fibular graft harvesting (n=1).
Spearman’s test was used to search for correlations. Results were compared with those measured under the same conditions in a series of 32 adult knees published by Wanner.
The femoral measurements showed 27.01° anteversion with very wide variability (coefficient 46%) and no correlation with trochlear opening. No significant differences were observed between the fœtal and adult measurements.
The twenty-two patients who achieved primary bone healing developed a hypertrophic graft (mean 61%, range 22 – 190%). Graft hypertrophy was not observed in the five cases requiring a secondary graft after the scintigram demonstrated lack of vascularisation. Hypertrophy of the vascularised fibular graft was more marked for lower limb reconstructions than for upper limb reconstructions.. Functional outcome was satisfactory in all cases. On the 30-point Enneking scale as modified, our patients achieved a mean 26 points (range 19 – 30).