Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Bone & Joint Open
Vol. 3, Issue 11 | Pages 885 - 893
14 Nov 2022
Goshima K Sawaguchi T Horii T Shigemoto K Iwai S

Aims

To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO).

Methods

Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 66 - 66
1 Jan 2016
Iwai S Kabata T Maeda T Kajino Y Tsuchiya H
Full Access

Background

Recently the taper wedged stems (TWS) are used widely in Japan because of good bone fixation and ease of the procedure. However, it is unclear how TWS get initial fixation in Japanese, especially dysplasia hip or elderly patients who had stovepipe canal. The purpose of this study is to evaluate initial bone fixation of the TWS in Japanese using computed tomography and to estimate biological bone fixation of the TWS using the Tomosynthesis.

Methods

We evaluated 100 hips underwent primary total hip arthroplasty using TWS. All patients were performed computed tomography within 2 weeks postoperatively and evaluated which part of the canal was made contact with the stem. 24 hips were male and 76 hips were female. According to the canal flare index, 9 hips were champagne flute canal, 80 hips were normal canal and 11 hips were Stovepipe canal. 10 hips were Dorr type A, 80 hips were Dorr type B and 10 hips were Dorr type C.

The initial bone fixation was classified as Medio-lateral fit (fixed at Gruen zone 2 and 7), Flare fit (fixed at zone 2 and 6), Varus 2-point fit (fixed at zone 3 and 7), Valgus 3-point fit (fixed at zone 2, 5 and 7), Distal fit (fixed at zone 3 and 5), Total fit (fixed at zone 2,3,5,6 and 7) by the stem A-P view. Moreover, we defined Medio-lateral fit, Flare fit and Total fit as Adequate fit, Varus 2-point fit and Valgus 3-point fit as Varus or Valgus fit, Distal fit as Distal fit. The stem alignment was classified as flexion, neutral and extension by the stem lateral view.

Femoral component fixation was graded as bone ingrowth, fibrous ingrowth and unstable by hip radiographs after surgery at 1 year. Spot-welds were evaluated using tomosynthesis after surgery at 6 months.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 306 - 311
1 Mar 2014
Fujita K Kabata T Maeda T Kajino Y Iwai S Kuroda K Hasegawa K Tsuchiya H

It has recently been reported that the transverse acetabular ligament (TAL) is helpful in determining the position of the acetabular component in total hip replacement (THR). In this study we used a computer-assisted navigation system to determine whether the TAL is useful as a landmark in THR. The study was carried out in 121 consecutive patients undergoing primary THR (134 hips), including 67 dysplastic hips (50%). There were 26 men (29 hips) and 95 women (105 hips) with a mean age of 60.2 years (17 to 82) at the time of operation. After identification of the TAL, its anteversion was measured intra-operatively by aligning the inferomedial rim of the trial acetabular component with the TAL using computer-assisted navigation. The TAL was identified in 112 hips (83.6%). Intra-observer reproducibility in the measurement of anteversion of the TAL was high, but inter-observer reproducibility was moderate.

Each surgeon was able to align the trial component according to the target value of the angle of anteversion of the TAL, but it was clear that methods may differ among surgeons. Of the measurements of the angle of anteversion of the TAL, 5.4% (6 of 112 hips) were outliers from the safe zone.

In summary, we found that the TAL is useful as a landmark when implanting the acetabular component within the safe zone in almost all hips, and to prevent it being implanted in retroversion in all hips, including dysplastic hips. However, as anteversion of the TAL may be excessive in a few hips, it is advisable to pay attention to individual variations, particularly in those with severe posterior pelvic tilt.

Cite this article: Bone Joint J 2014;96-B:306–11.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 230 - 230
1 Mar 2013
Kuroda K Kabata T Maeda T Kajino Y Iwai S Fujita K Tsuchiya H
Full Access

Objective

In total hip arthroplasty (THA), the femoral component influences leg length inequality and gait, and is associated with poor muscle strength and other unsatisfactory long-term results. We have therefore used intraoperative radiographs to acquire accurate measurements of femoral component size and position. At the last meeting of this society, we reported that accurate positioning was successfully achieved in 68 cases (87.2%) as a consequence of taking intraoperative radiographs. However, we have little understanding as regards to the accuracy of X-ray measurements. We accordingly undertook an examination of the accuracy of such measurements. The purpose of this study was to evaluate the difference between leg length discrepancy (LLD) measured using X-ray and computed tomography (CT).

Materials and Methods

The study group comprised 48 primary THAs performed between October 2010 and April 2012. Using 2D template software (JMM Corporation), we measured LLD using pre-operative anteroposterior (AP) radiographs of the pelvis. On the basis of both teardrop lines, we measured LLD of the lesser trochanter top (Fig. 1), lesser trochanter direct top (Fig. 2), and trochanteric top (Fig. 3). Furthermore, using Aquarius NET software, we measured LLD using AP and lateral scout views of the pelvis and bilateral femurs. This data was defined as the true LLD. The difference between the X-ray data (lesser trochanter top, lesser trochanter direct top, and trochanteric top) and the CT data was defined as accuracy. Additionally, we measured the size of the lesser trochanter and examined the association.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 88 - 88
1 Mar 2013
Kajino Y Kabata T Maeda T Iwai S Kuroda K Fujita K Kawashima H Sanada S Tsuchiya H
Full Access

Introduction

Hip resurfacing arthroplasty has been surgical options in younger and more active patients with osteoarthritis (OA) and osteonecrosis (ON) of the femoral head. Although excellent midterm results of this procedure have been reported, there is a concern about postoperative impingement between the preserved femoral neck and the acetabular component. There were few reports about kinematics after hip resurfacing. Therefore, the purpose of this study was to investigate the postoperative motion analysis after hip resurfacing using a noble dynamic flat-panel detector (FPD) system by which clear sequential images were obtained with low dose radiation exposure.

Materials and methods

11 patients (mean age: 47.8 ± 7.4), 15 hips were included in this study. There were ten men and one woman. The preoperative diagnoses were ON of the femoral head in 10 hips, OA in 3 hips, and others in 2 hips. Mean postoperative follow-up period was 25.1 ± 21.6 months. Femoral anteversion, cup inclination and cup anteversion were measured on computed tomography and plain radiograph. Impingement signs such as the reactive osteophyte formation and divot around the femoral neck were also investigated on the anteroposterior (AP) and lateral radiographs. Sequential images of active and passive flexion motion in 45-degrees semilateral position, and active abduction motion in a supine position were obtained using a noble dynamic FPD system.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 175 - 175
1 Mar 2013
Fujita K Kabata T Maeda T Kajino Y Iwai S Kuroda K Tsuchiya H
Full Access

Introduction

The aim of this study was to assess the accuracy of aligning the cup with the transverse acetabular ligament (TAL) in total hip arthroplasty (THA) and the reproducibility of this procedure by using computer-assisted navigation.

Methods

Between January 2011 and March 2012, 75 patients (81 hips) underwent primary THA using the posterolateral approach at our hospital. We excluded 4 hips with a history of pelvic osteotomy; thus, the study included 77 hips. We measured the anatomical anteversion of the TAL intraoperatively by aligning the inferomedial rim of the cup trial with the TAL using computer-assisted navigation. We set the abduction to 45° at measure of the anteversion of the TAL. Measurements for each hip were independently performed thrice by 2 surgeons chosen among 1 expert and 6 non-experts. The surgeon performing the measurement was blinded during this process; the navigation screen was turned away from the surgeon's field of view. Anatomical inclination and anteversion were measured with reference to the functional pelvic plane. The intraclass correlation coefficient (ICC) was used to assess intra- and inter-observer reliability. The mean value of all 6 measurements was used to determine the anteversion of the TAL in each hip.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 248 - 248
1 Mar 2013
Maeda T Kabata T Kajino Y Hayashi H Iwai S Kuroda K Fujita K Tsuchiya H
Full Access

Introduction

Intramedullary femoral alignment guide is mostly used in total knee arthroplasty (TKA). Accurate preoperative plan is critical to get good alignments when we use intramedullary femoral guide, because the center of femoral head cannot be looked directly during operation. Commonly, the planning is carried out using preoperative anteroposterior radiographs of the femur. The angles formed between mechanical axes of the femur and distal femoral anatomic axes (AMA) are measured as reference angles of resection of distal femur, and the entry points of intramedullary femoral guide are also planned. The purpose of this study is to investigate the influence of femoral position on radiographic planning in TKA.

Materials and Methods

We examined 20 knees of 20 female patients who received TKA. Fourteen patients suffered from primary osteoarthritis of the knees, and 6 suffered from rheumatoid arthritis. Fifteen patients have varus knee deformities and 5 patients have valgus knee deformities. Long leg computed topography scans were performed in all cases before operations, and all images were stored in DICOM file format. The analyses were performed with computer software (3D template, JMM, Osaka, Japan) using DICOM formatted data. The planes containing the center of femoral head and transepicondylar axes were defined as reference planes, and the reference planes were fixed all through analyses. At first, to assess the influence of femoral rotation, the femur was rotated from 30 degrees external rotation to 30 degrees internal rotation in 5 degrees increments in full extension. After that, to examine the influence of knee flexion, the knee was bended from full extension to 30 degrees flexion in 5 degrees increments in neutral rotation. Reconstructed coronal planes parallel to the reference planes were made, the angles between mechanical axes of the femur and distal femoral anatomic axes (AMA) and the distance from entry points to the center of femoral intercondylar notch were measured in each position. The distal anatomic axes were made by connecting the center of femoral canal at 8 centimeters proximal to joint line and that at 16 centimeters proximal to joint line. The entry points of intramedullary femoral guide were defined the points where distal anatomic axes meets intercondylar notch.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 203 - 203
1 Mar 2013
Iwai S Kabata T Maeda T Kajino Y Kuroda K Fujita K Tsuchiya H
Full Access

Background

Rotational acetabular osteotomy (RAO) is an effective treatment option for symptomatic acetabular dysplasia. However, excessive lateral and anterior correction during the periacetabular osteotomy may lead to femoroacetabular impingement. We used preoperative planning software for total hip arthroplasty to perform femoroacetabular impingement simulations before and after rotational acetabular osteotomies.

Methods

We evaluated 11 hips in 11 patients with available computed tomography taken before and after RAO. All cases were female and mean age at the time of surgery was 35.9 years. All cases were early stage osteoarthritis without obvious osteophytes or joint space narrowing.

Radiographic analysis included the center-edge (CE) angle, Sharp's acetabular angle, the acetabular roof angle, the acetabular head index (AHI), cross-over sign, and posterior wall sign. Acetabular anteversion was measured at every 5 mm slice level in the femoral head using preoperative and postoperative computed tomography.

Impingement simulations were performed using the preoperative planning software ZedHip (LEXI, Tokyo, Japan). In brief, we created a three-dimensional model. The range of motion which causes bone-to-bone impingement was evaluated in flexion (flex), abduction (abd), external rotation in flex 0°, and internal rotation in flex 90°. The lesions caused by impingement were evaluated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 75 - 75
1 Sep 2012
Iwai S Kabata T Maeda T Kajino Y Ogawa K Kuroda K Tsuchiya H
Full Access

Introduction

Alumina-on-alumina bearings exhibit low wear rates in vitro and one commonly used ceramic implant is the Trident system (Stryker, Mahwah, NJ). There are some reports of incomplete seating of the ceramic liner in the Trident acetabular shell. However, it is often difficult to detect incomplete seating intraoperatively. We sought to prevent incomplete seating using intraoperative radiography.

Materials and Methods

We retrospectively reviewed 19 hips in 17 patients who had undergone primary total hip arthroplasty using a Trident shell with a metal-backed alumina liner between 2007 and 2010. There were 16 women and 1 man, with an average age of 45.7 years. Preoperative diagnosis revealed 14 cases of osteoarthritis and 5 cases of osteonecrosis. All procedures were performed using a posterolateral approach with PSL cups. The minimum follow-up time was 12 months (average 28 months). All procedures included an intraoperative anteroposterior view radiograph to evaluate cup seating. If incomplete seating was recognized we reinserted the liner. Postoperatively, radiographs (supine anteroposterior and cross table lateral views) and computed tomography were performed in all cases in order to assess any residual incomplete seating. We investigated whether it was possible to avoid incomplete seating using intraoperative radiography.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 111 - 114
1 Jan 2011
Iwai S Sato K Nakamura T Okazaki M Itoh Y Toyama Y Ikegami H

We present a case of post-traumatic osteonecrosis of the radial head in a 13-year-old boy which was treated with costo-osteochondral grafts. A satisfactory outcome was seen at a follow-up of two years and ten months.

Although costo-osteochondral grafting has been used in the treatment of defects in articular cartilage, especially in the hand and the elbow, the extension of the technique to manage post-traumatic osteonecrosis of the radial head in a child has not previously been reported in the English language literature. Complete relief of pain was obtained and an improvement in the range of movement was observed. The long-term results remain uncertain.