Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 97 - 102
1 Jan 2022
Hijikata Y Kamitani T Nakahara M Kumamoto S Sakai T Itaya T Yamazaki H Ogawa Y Kusumegi A Inoue T Yoshida T Furue N Fukuhara S Yamamoto Y

Aims

To develop and internally validate a preoperative clinical prediction model for acute adjacent vertebral fracture (AVF) after vertebral augmentation to support preoperative decision-making, named the after vertebral augmentation (AVA) score.

Methods

In this prognostic study, a multicentre, retrospective single-level vertebral augmentation cohort of 377 patients from six Japanese hospitals was used to derive an AVF prediction model. Backward stepwise selection (p < 0.05) was used to select preoperative clinical and imaging predictors for acute AVF after vertebral augmentation for up to one month, from 14 predictors. We assigned a score to each selected variable based on the regression coefficient and developed the AVA scoring system. We evaluated sensitivity and specificity for each cut-off, area under the curve (AUC), and calibration as diagnostic performance. Internal validation was conducted using bootstrapping to correct the optimism.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1472 - 1478
1 Sep 2021
Shoji T Saka H Inoue T Kato Y Fujiwara Y Yamasaki T Yasunaga Y Adachi N

Aims

Rotational acetabular osteotomy (RAO) has been reported to be effective in improving symptoms and preventing osteoarthritis (OA) progression in patients with mild to severe develomental dysplasia of the hip (DDH). However, some patients develop secondary OA even when the preoperative joint space is normal; determining who will progress to OA is difficult. We evaluated whether the preoperative cartilage condition may predict OA progression following surgery using T2 mapping MRI.

Methods

We reviewed 61 hips with early-stage OA in 61 patients who underwent RAO for DDH. They underwent preoperative and five-year postoperative radiological analysis of the hip. Those with a joint space narrowing of more than 1 mm were considered to have 'OA progression'. Preoperative assessment of articular cartilage was also performed using 3T MRI with the T2 mapping technique. The region of interest was defined as the weightbearing portion of the acetabulum and femoral head.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 42 - 42
1 Mar 2017
Tamaki S Tonai T Kimura T Sasa T Inoue T
Full Access

Objective

Bacterial infection is a serious complication after joint replacement surgery. In particular, methicillin-resistant Staphylococcus aureus (MRSA) and epidermidis(MRSE) are very difficult to eradicate in infected prosthetic joint. Therefore, the retention rate of initial prosthesis affected with such resistant microorganisms is still low. Gentian violet shows potent antibacterial activity against gram-positive cocci as minimal bactericidal concentration is less than 0.1 %. In the present study, we investigated the efficacy of treatment with gentian violet against MRSA and MRSE infections after THA, TKA, and bipolar hip hemiarthroplasty (BHP).

Methods

There were 8 patients in this study; five patients with deep periprosthetic MRSA infection (2 THA, 2 BHP, 1 revision TKA); 3 patients with MRSE infection (1 revision THA, 1 BHP, 1 TKA). When infection was suspected after the surgery, we quickly obtained synovial fluid and periprosthetic soft tissue from the joint and applied to culture and microscopic examinations for detection of microorganisms. After identification of bacterial species, we immediately debrided the affected joint and washed thoroughly twice with 0.1% solution of gentian violet for 3 minutes each, followed by intra-articular multiple injection of arbekacin sulfate solution. Then we inserted an aspiration tube into the joint and administered appropriate antibiotics intravenously. If the inflammatory symptoms persisted in spite of the first treatment, we repeated the treatment until inflammation signs and intra-articular microorganisms could not be detected.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 142 - 142
1 May 2016
Fujii Y Fujiwara K Endou H Tetsunaga T Ozaki T Abe N Sugita N Mitsuishi M Inoue T Nakashima Y
Full Access

Object

CT-based navigation system in total hip arthroplasty(THA) is widely used to achieve accurate implant placement. However, its internal structure was a trade secret. Therefore, it was hard to analyze optimal reference points. Now, we developed our own CT-based navigation system originally, and since then we have been conducting various analyses in order to use the system more effectively. The purpose of this study was to analyze the optimal area and the number of registration points, which enables to move initial errors into the acceptable range.

Methods

We set the anterior pelvic plane(APP) as the reference plane, and defined the coordinates as follows: X-axis for external direction, Y-axis for anterior direction, and Z-axis for proximal direction. We made pelvic bone models after THA, a normal shape and acetabular dysplasia model, and performed registration using an originally developed CT based navigation system. At first, we registered point paired matching at 4 points, and surface matching was performed at 53 points, which were placed around the acetabulum. 20 points were on anterosuperior, 10 points were on posterosuperior, 20 points were on posterior around the acetabulum, and 3 points were on the pubis. We selected surface matching points based on the actual operation approach, calculated the accuracy of the error correction, and searched the optimal area and the number of surface matching points.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 137 - 137
1 Jan 2016
Fujii Y Fujiwara K Endou H Kagawa Y Ozaki T Abe N Sugita N Mitsuishi M Inoue T Nakashima Y
Full Access

Background

CT-based navigation system in total hip arthroplasty(THA) is widely used to achieve accurate implant placement. The purpose of this study was to evaluate the influence of initial error correction according to the differences in the shape of the acetabulum, and correction accuracy associated with operation approach after localization of registration points at anterior or posterior area of the acetabulum.

Methods

We set the anterior pelvic plane(APP) as the reference plane, and defined the coordinates as follows: X-axis for external direction, Y-axis for anterior direction, and Z-axis for proximal direction. APP is defined by the anterior superior iliac spines and anterior border of the pubic symphysis. We made a bone model of bilateral acetabular dysplasia of the hip, after rotational acetabulum osteotomy(RAO) on one side, and performed registration using infrared-reflective markers. At first, we registered the initial error on navigation system, and calculated the accuracy of the error correction based on each shape of the acetabulum as we increased the surface matching points. Based on the actual operation approach, we also examined the accuracy of the error correction when concentrating the matching points in anterior or posterior areas of the acetabulum.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 61 - 61
1 Jan 2016
Inoue T Yokokura T Yamamoto Y Nagamura K Nakanishi Y
Full Access

Cases of intertrochanteric hip fractures as a result of osteoporosis have been increasing in recent years. Treatment of these types of fractures is often performed with intramedullary (IM) nails or compression hip screws (CHS) [1]. IM nails are composed of a stem, which is inserted into the medullary canal of the femur, and a lag screw that is placed inside the head of the femur. One problem with this type of device is that both the left and right femurs are fixed with IM nails that have right-hand threaded lag screws. Therefore, on left femurs, the right-handed threads may not provide satisfactory fixation in the bone. This insufficient fixation could cause rotary motion and slippage in the femoral head, which would inhibit fracture healing. This study used three-dimensional finite element analysis (FEA) to examine the fixation and rotational characteristics in reference to the thread direction of the lag screw and the relative angle between the stem and lag screw.

In this study, a 3D CAD model of a left femur and four proximal femoral IM nail designs were analyzed in FEA for stress and displacement. An intertrochanteric femoral fracture was created so that the femoral head and diaphysis were separated. The four IM nails were designed to with either left or right-handed lag screw threads (figure .1) and with relative stem-lag screw angles of 125 or 135 degrees. (Traditional IM nails use a right-handed screw and a relative angle of 125 degrees.)

The results showed the femoral head displacement was smaller when using the left-handed lag screw. It is thought that this difference between the left and right-handed screws is caused by the direction of rotation, which would cause the left-handed screw to tighten and the right-handed screw to loosen within the femoral head. The femoral head displacement also decreased with a screw-stem angle of 135 degrees in comparison to the standard 125 degree angle. The standard right-handed screw with 125 degree relative angle was shown to have the largest displacement of all four types of tested IM nails, whereas the left-handed, 135 relative degree design produced the smallest displacement of all four implants.

These results show how using a left-handed lag screw with proper relative angles in the left femur, effectively reduces femoral head displacement when compared to traditional right-handed lag screw IM implants. This is important for the promotion of intertrochanteric fracture healing.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 167 - 167
1 May 2012
Chazono M Tanaka T Soshi S Inoue T Kida Y Nakamura Y Shinohara A Marumo K
Full Access

The use of cervical pedicle screws as anchors in posterior reconstruction surgery has not been widely accepted due to the neurological or vascular injury. We thus sought to investigate the accuracy of free-handed pedicle screw placement in the cervical and upper thoracic spine at the early stage of clinical application.

Eight patients (five males and three females) were included in this study. Mean age was 63 years (31 to 78 years). There were three patients with rheumatoid arthritis, three with cervical fracture-dislocation, and two with spinal metastasis. Twenty-four pedicle screws (3.5 mm diameter: Vertex, Medtronic Sofamordanek) were placed into the pedicle from C2 to T2 level by free-handed technique2). Grade of breaching of pedicle cortex was divided into four groups (Grade 0–3). In addition, screw axis angle (SAA) were calculated from the horizontal and sagittal CT images and compared with pedicle transverse angle (PTA). Furthermore, perioperative complications were also examined.

Our free-handed pedicle screw placement with carving technique is as follows: A longitudinal gutter was created at the lamina-lateral mass junction and then transverse gutter perpendicular to the longitudinal gutter was made at the lateral notch of lateral mass. The entry point of the pedicle screw was on the midline of lateral mass. Medial pedicle cortex through the ventral lamina was identified using the probes to create the hole within the pedicle. The hole was tapped and the screw was gently introduced into the pedicle to ensure the sagittal trajectory using fluoroscopy. In the transverse direction, 22 out of 24 screws (92%) were entirely contained within the pedicle (Grade 0). In contrast, only teo screws (8%) produced breaches less than half the screw diameter (Grade 1). In the sagittal direction, all screws were within the pedicle (Grade 0). Screw trajectories were not consistent with anatomical pedicle axis angle; the mean SAA were smaller than the mean PTA at all levels. The pedicle diameter ranged from 3.9 to 9.2 mm. The mean value gradually increased toward the caudal level. There were no neurological and vascular complications related to screw placement.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 450 - 450
1 Nov 2011
Fujiwara K Abe N Endo H Nishida K Mitani S Ozaki T Suzuki M Saito T Sugita N Nakajima Y Mitsuishi M Inoue T Kuramoto K Nakashima Y
Full Access

ROBODOC is a well known tool for a computer assisted arthroplasty. However, the incision tends to enlarge with the system because of the restriction of range of motion. We have developed the robot system for minimally invasive arthroplasty. This report shows the accuracy of our system composed of original planning software, navigation and bone cutting robot.

We took the DICOM data of cadaver knees from computed tomography. The data were transferred to the workstation for planning. Matching points for registration and cutting planes were determined on the planning software. Cutting tool was the 6th robot which was able to recognize the locations of its apex and the cadaver knee with navigation system. We made five planes for TKA and two planes for UKA on femur. Then we made one plane on tibia. We evaluated the accuracy by measurement the location of cutting plane under navigation system and by CT data.

The registration errors of femur and tibia were less than 1.0mm about cadaver knees. The errors of cutting planes were 1.3 mm about the distal end of femur and 0.5 mm about the proximal end of tibia. The accuracies of the angles of cutting planes were 1.9 degrees and 0.8 degrees compared to the mechanical axis.

The errors of anterior and posterior plane of femur were increased compared to the distal plane. It was because the accuracy of registration were correct in axial direction but was not satisfied in rotational direction. The error was considered by the location of points which decided the rotation alignment. We will make effort to minimize the errors of registration and put it into practical use as soon as possible.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 682 - 687
1 May 2006
Kanazawa T Soejima T Murakami H Inoue T Katouda M Nagata K

We studied bone-tendon healing using immunohistochemical methods in a rabbit model.

Reconstruction of the anterior cruciate ligament was undertaken using semitendinosus tendon in 20 rabbits. Immunohistochemical evaluations were performed at one, two, four and eight weeks after the operation. The expression of CD31, RAM-11, VEGF, b-FGF, S-100 protein and collagen I, II and III in the bone-tendon interface was very similar to that in the endochondral ossification. Some of the type-III collagen in the outer layer of the graft, which was deposited at a very early phase after the operation, was believed to have matured into Sharpey-like fibres. However, remodelling of the tendon grafted into the bone tunnel was significantly delayed when compared with this ossification process. To promote healing, we believe that it is necessary to accelerate remodelling of the tendon, simultaneously with the augmentation of the ossification.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 760 - 767
1 Jul 2000
Watanabe H Shinozaki T Yanagawa T Aoki J Tokunaga M Inoue T Endo K Mohara S Sano K Takagishi K

We performed positron emission tomography (PET) with 18fluorine-fluoro-2-deoxy-D-glucose (FDG) on 55 patients with tumours involving the musculoskeletal system in order to evaluate its role in operative planning. The standardised uptake value (SUV) of FDG was calculated and, to distinguish malignancies from benign lesions, the cases were divided into high (≥ 1.9) and low (< 1.9) SUV groups.

The sensitivity of PET for correctly diagnosing malignancy was 100% with a specificity of 76.9% and an overall accuracy of 83.0%. The mean SUV for metastatic lesions was twice that for primary sarcomas (p < 0.0015).

Our results suggest that the SUV may be useful in differentiating malignant tumours from benign lesions. However, some of the latter, such as schwannomas, had high SUVs so that biopsy or wide resection was selected as the first operation. Thus, some other quantitative analysis may be required for preoperative planning in cases of high-SUV neurogenic benign tumours. The reverse transcription-polymerase chain reaction revealed that the RNA message of a key enzyme in glucose metabolism, phosphohexose isomerase (PHI)/autocrine motility factor, was augmented in only high FDG-uptake lesions, suggesting that a high expression of the PHI message may be associated with accumulation of FDG in musculoskeletal tumours.