Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 266 - 266
1 Mar 2013
Miyoshi N Suenaga N Oizumi N Inoue K Ito H
Full Access

Introduction

Although Total elbow arthroplasty (TEA) generally provides favorable clinical outcomes, its complications have been reported with high rate compared with other joints. Previously, we used the Bryan & Morrey approach in TEA, which included separating the triceps muscle subperiosteally from the olecranon; however, since 2008, in order to prevent skin trouble and deficiency of the triceps, we performed TEA by MISTEA method, which required no removal of the subcutaneous tissue in the region of the olecranon and no release or stripping of the triceps tendon.

Objectives

The purpose of this study was to examine the utility of the MISTEA method by evaluating and comparing muscle strength and complications by using both the Bryan & Morrey approach and MISTEA method.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 80 - 80
1 Oct 2012
Yanagimoto S Tezuka M Kameyama M Inoue K Nakayama S Komiyama T Okada E Takeda K Fujita Y Funayama A
Full Access

We have used CT-based total hip navigation system from 2003, to set the acetabular socket in optimal position. At first, we had used CT-based land-mark matching system. It needs matching procedure during surgery, touching paired points in surgical exposure. From 2006, we started to use new navigation system, called CT-based fluoroscopy-matching system, which was developed by BrainLAB Company (Vector-vision 2.7.1., 3.5.1.). For this new system, pre-surgical image matching procedure is need. Fluoroscopic images with 2 different directions must be taken in operation room. Then fluoroscopic images and CT reconstructive images were matched in computer with special program. Matching procedure was done before surgical incision. We compared the advantage of these two systems about technical problem, radiation exposure, time need for procedure, and accuracy. And then we discussed how to use these two different systems for THA patients.

Accuracy was compared for 241 THA patients using these navigation systems. 152 cases were with CT-based land-mark matching system and 89 patients with CT-based fluoroscopy matching system. Final verification angle of acetabular socket setting in navigation during surgery was recorded for each case. The operative angle, which is referred from Murray, is used to show the socket setting angle (inclination and anteversion) in these navigation systems. Post-operative CT scan was taken to evaluate the actual socket setting angle. The values between verification angle during surgery and post-operative CT measured angle were calculated and compared statistically.

Results were followed. New CT-based fluoroscopy matching method (F method): Average setting angle (operative angle) of socket in these 89 cases were 42.9 +/− 5.1 degree in inclination angle, and 28.5 +/− 7.9 degree in anteversion angle. The absolute difference in 89 cases between final verification angle and post-operative CT measurement angle was 2.9 degree (on average) +/− 2.5 degree in inclination angle, and 2.8 degree (on average) +/− 2.6 degree in anteversion angle. Conventional CT-based land-mark matching method (L method): The absolute difference in 152 cases between final verification angle and post-operative CT measurement angle was 4.2 degree (on average) +/− 3.2 degree in inclination angle, and 4.4 degree (on average), +/− 3.7 degree in anteversion angle. Absolute differences of setting angle in fluoroscopy matching groups showed statistically low compared with land-mark matching groups (P<0.01).

Technical problems: L method is difficult to learn actual procedure. F method is easy to learn procedure. Image matching was done automatically by computer program. Radiation exposure during surgery: L method needs no additional radiation. F method needs radiation to get 2 fluoroscopic images. Total amount time need for navigation: L method needs extra 10 minutes during surgery in case of skilled-doctor. F method needs extra 20 minutes before starting surgery in case of all kind doctors. The accuracy of acetabular socket setting: Absolute errors in socket setting with theses two systems were within 5 degree together on average. These results showed the usefulness of both systems. Compared the accuracy between these 2 systems, F methods showed high accuracy. The accuracy of F methods is always high. It has no influence with deformity around hip joint, because fluoroscopic image matching was done with lower part of pubic bone, especially around symphysis pubis.

For ordinary THA cases with skilled-doctor, CT-based land-mark matching system is useful, because this system is very convenient and needs only extra 10 minutes during surgery. For severe deformed cases with all kind doctors, CT-based fluoroscopy matching system is useful, because this system showed high accuracy even for severe deformed cases. Before surgical incision, fluoroscopic matching procedure has finished. This system needs no extra time after surgery starts.