header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 81 - 81
1 Mar 2013
Iwaki H Minoda Y Ikebuchi M Ohta Y Itokazu M Nakamura H
Full Access

INTRODUCTION

Cup orientation of total hip arthroplasty (THA) is critical for dislocation, range of motion, polyethylene wear, pelvic osteolysis, and component migration. But, substantial error under manual technique has been reported specially in revision THA due to a bone loss and poor anatomical landmark. We have used three kinds of navigation systems for cup positioning in primary and revision THA.

OBJECTIVES

The purpose of this study is to evaluate the accuracy of navigation in revision THAs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 262 - 262
1 Mar 2013
Minoda Y Iwaki H Yoshida T Ikebuchi M Mizokawa S Inori F Itokazu M Maki T Sugimoto K Nakamura H
Full Access

INTRODUCTION

Recently, as the number of total knee arthroplasty (TKA) is increasing, the number of revision TKA due to loosening or osteolysis is rapidly increasing. Large bone defect is one of the most critical issues during revision TKA. Therefore, early detection of bone loss around the TKA prosthesis before bone loss has been enlarged is very important. However, it is difficult to detect the loosening or ostolysis at the early stage around the femoral component even using fluoroscopically guided plain radiograph. A novel technique of tomography (Tomosynthesis; Shimazu Corporation, Kyoto, Japan) was introduced to detect the small bone loss. The purpose of this study was to examine, in a pig model of radiolucent line and osteolysis around TKA, the sensitivity and specificity of detection of radiolucent line and osteolysis using fluoroscopically guided plain radiographs and a novel technique of tomography.

METHODS

Six cemented femoral components (PFC Sigma; DePuy, Warsaw, IN, USA) were implanted in pig knees. Two components were implanted with standard cement technique (Standard model). Two components were implanted with 2 mm-thick defect between the cement and bone (Radiolucent line model). Two components were implanted with cystic defects (mean size = 0.7 cm3) in femoral condyles (Osteolysis model). The simulated bone lesions were filled with agarose to simulate granuloma tissue and to reduce the air artifact around the bone lesions, which can interfere with imaging techniques (Figure 1). Fluoroscopically guided plain radiographs (63 kV, 360 mA, 50 msec) were taken in 4 postures (antero-posterior, lateral, and +/−45 degrees oblique views) for each specimen (Figure 2). For Tomosynthesis, 74 frames were acquired in the rate 30 frames/sec with fixed X-ray condition (65 kV 1.25 mAs) and were reconstructed (Figure 3). Seven blinded assessors experienced in clinical radiographic analysis examined. The sensitivities, specificities and accuracy of the two imaging techniques were compared.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 110 - 110
1 Sep 2012
Minoda Y Kadoya Y Kobayashi A Iwaki H Iwakiri K Iida T Matsui Y Ikebuchi M Yoshida T Nakamura H
Full Access

Over the past decade, there has been an increase in the number of total knee arthropalsty (TKA). Demand of TKA for the young patients who often have high physical demands is also increasing. However, the revision rate in such young patients is much higher due to polyethylene (PE) wear and instability (Julin J, Acta Orthop 2010). Therefore, next generation total knee prostheses are expected to decrease PE wear and to provide stability.

Although in vitro study such as wear simulator test provides important information about PE wear, we have often encountered the discrepancy between the in vitro results and in vivo results. Thus we have performed in vivo PE wear particle analysis, and showed that in vivo PE wear was affected by the design of articulating surface and the materials of femoral component and PE insert (Minoda Y, JBJS Am 2009). Medial pivot design, ceramic femoral component, and highly cross-linked PE decreased in vivo PE wear particle generation.

Patients who underwent bilateral staged TKAs were more likely to prefer medial pivot prosthesis or ACL-PCL retaining prosthesis than the other types of prostheses, because they feels “more stable overall” (Pritchett JW, J Arthroplasty 2011). In vivo fluoroscopic 3D analysis showed that medical pivot and bi-cruciate substituting designs restored physiological knee motion and provided higher reproducibility (Mueller J. Komistek RD, Trans ORS 2009, Iwakiri K, Trans ORS 2007).

The excellent mid-term clinical results of those newly introduced total knee prosthesis, such as alumina medial pivot TKA (Iida T, ORS 2008), medial pivot TKA (Mannan K, JBJS Br 2009, Kakachalions T, Knee 2009), ACL-PCL retaining TKA (Clouter JM, JBJS Am 1999), and highly cross-linked PE (Hodrick JT, CORR 2008), have been reported.

From the point of view of in vivo PE wear, in vivo stability, and the mid-term clinical results, we suspect that medial pivot prosthesis is one of the prostheses which meet the demand in future especially for young active patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 102 - 102
1 Jun 2012
Iwaki H Yoshida T Ikebuchi M Minoda Y Iida T Ikawa T Nakamura H
Full Access

Introduction

There is many reports about complications with a resurfacing total hip arthroplasty (RHA). One of the most common complications is the femoral neck fracture. A notch and malalignment were risk factors for this. For an accurate implanting the femoral component in RHA, we performed 3D template and made a patient specific template (PST) using 3D printer and applied this technique for a clinical usage. We report a preliminary early result using this novel technique.

material and method

We performed 10 RHAs in nine patients (7 male, 2 female) from June 2009 to March 2010 due to osteonecrosis in 7 hips and secondary osteoarthritis in 3hips with a mean age of 48 years (40-60). We obtained a volumetric data from pre-operative CT and planned using 3D CAD software. Firstly, size of femoral components were decided from the size planning of cups. We aimed a femoral component angle as ten degrees valgus to the neck axis in AP and parallel in lateral view avoiding a notch. We measured femoral shaft axis and femoral neck axis in AP and lateral view using 3D processing software. PSTs were made using Laser Sintering by 3D printer which had the heat tolerance for sterilization in order to insert the femoral guide wire correctly. We operated in postero-lateral approach for all the patients PST has the base (contact part) fit to poterior inter trochanteric area. It has the arm reached from the base and sleeve hole to insert the guide pin into the femoral head. We measured the femoral component angle in three dimensions using the 3D processing software postoperatively. We compared the difference of this angle and the pre-operative planed angles. We also investigated the operation time, the volume of bleeding during operation and complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 794 - 798
1 Jun 2010
Minoda Y Ikebuchi M Kobayashi A Iwaki H Inori F Nakamura H

Bone mineral density (BMD) around the femoral component has been reported to decrease after total knee replacement (TKR) because of stress shielding. Our aim was to determine whether a cemented mobile-bearing component reduced the post-operative loss of BMD. In our study 28 knees receiving a cemented fixed-bearing TKR were matched with 28 receiving a cemented mobile-bearing TKR. They underwent dual-energy x-ray absorptiometry, pre-operatively and at three weeks and at three, six, 12, 18 and 24 months post-operatively. The patients were not taking medication to improve the BMD.

The pre-operative differences in the BMD of the femoral neck, wrist, lumbar spine and knee in the two groups were not significant. The BMD of the femur decreased postoperatively in the fixed-bearing group, but not the mobile-bearing group. The difference in the post-operative change in the BMD in the two groups was statistically significant (p < 0.05) at 18 and 24 months.

Our findings show that a cemented mobile-bearing TKR has a favourable effect on the BMD of the distal femur after TKR in the short term. Further study is required to determine the long-term effects.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 151 - 152
1 Mar 2010
Inori F Minoda Y Kobayashi A Iwaki H Ikebuchi M Ohashi H Takaoka K
Full Access

The introduction of porous tantalum metal (Trabecular Metal; Zimmer, Warsaw, IN) for acetabular component fixation in total hip arthroplasty has shown optimum fixation qualities and “gap filling” effect. Recently, trabecular metal was introduced in tibial component for total knee prosthesis, however its effect on the bone mineral density (BMD) was not reported. The purpose of this study was to compare the BMD of proximal part of the tibia between trabecular metal and another cemented tibial component.

31 knees receiving trabecular metal tibial component and 33 knees receiving cemented tibial component (PFC Sigma RP, Depuy, Warsaw, IN) had dual energy x-ray absorptiometry (DEXA) scans at preoperatively and 3 weeks, 3, 6, 12, 18, 24 months post-operatively. To assess peri-prosthetic BMD, three regions of interest (ROI) were measured for each case. They were medial aspect (ROI 1), center aspect (ROI 2) and lateral aspect (ROI 3) of tibia. Average follow up period was 1.8 (range: 1.5 to 2) years. In both groups, BMD in tibia decrease postoperatively. Comparing postoperative decrease of BMD in lateral aspect of tibia (ROI 3) between both groups, it was significantly less in trabecular metal component (−0.09 g/cm2 +/−0.27) than cemented tibial component (−0.31 g/cm2 +/− 0.21) (p=0.0007).

We conclude that trabecular metal tibial component showed a favorable effect on BMD of proximal part of the tibia after total knee arthroplsaty.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 110 - 111
1 Mar 2010
Iwaki H Minoda Y Ikebuchi M Fukunaga K Iida T Takaoka K
Full Access

Cup orientation of total hip arthroplasty (THA) is critical for dislocation, range of motion, polyethylene wear, pelvic osteolysis, and component migration. But, substantial error under manual technique has been reported. Therefore, various navigation systems were introduced to reduce outliers. CT based navigation (CTN) was reported to reduce outliers in cup orientation. Recently, a noble technique, fluoroscopy-CT-based navigation (FCTN), has recently been developed using 2D-3D matching technique. Because of much less registration points, FCTN might be friendly to MIS THA and cases with sever bone deformity. Between October 2006 and April 2008, 33 THAs were performed through MIS approach with navigations.

We prospectively randomized those into two groups, CTN and FCTN groups. We implanted cementless hemispherical cups in 18 hips using CTN (VectorVision CT Hip 3.1) and in 15 hips using FCTN (VectorVision CT Hip 3.5). For all the patients, volumetric post-operative CT scan was performed to measure 3D cup orientation. using 3D image-processing software (JMM, Japan). The difference from target angles of anteversion was 2.7 ± 2.4 degrees in FCTN group, and 12.1 ± 5.7 degrees in CTN group (p < 0.001). The absolute value of difference from target angles of inclination was 2.7 ± 2.4 degrees in FCTN group, and 6.5 ± 4.5 degrees in CTN group (p = 0.006). FCTN does not need surface registration around acetabulum, which is great advantage to MIS THA. Our study clearly showed that FCTN significantly improved a cup orientation to CTN.