Most common osteoporotic fracture 20-30% of patients with OVFs are presented to hospital while 2.2 million remain undiagnosed, as diagnosis is usually opportunistic 66,000 OVFs occur annually in the UK with increase by 18,000 cases a year until 2025. 20% chance of another OVF in next 12 months and 3 times risk of hip fracture. Acute painful OVFs poorly tolerated by infirm elderly patients, leading to significant morbidity and 8 times increase in age-adjusted mortality. Classify fracture severity and patents with ovfs in 12-month period. To assess follow-up status and if kyphoplasty was offered within 6 weeks as per NICE guidelines. To introduce Royal Osteoporosis Society and GIRFT guidelines on management of symptomatic osteoporotic vertebral fracturesIntroduction
Materials and Methods
Gram-negative prosthetic joint infections (GN-PJI) present unique challenges in management due to their distinct pathogenesis of biofilm formation on implant surfaces. To date, there are no animal models that can fully recapitulate how a biofilm is challenged in vivo in the setting of GN-PJI. The purpose of this study is to establish a clinically representative GN-PJI in vivo model that can reliably depict biofilm formation on titanium implant surface. We hypothesized that the biofilm formation on the implant surface would affect the ability of the implant to be osseointegrated. The model was developed using a 3D-printed, medical-grade titanium (Ti-6Al-4V), monoblock, cementless hemiarthroplasty hip implant. This implant was used to replace the femoral head of a Sprague-Dawley rat using a posterior surgical approach. To induce PJI, two bioluminescent Pseudomonas aeruginosa (PA) strains were utilized: a reference strain (PA14-lux) and a mutant strain that is defective in biofilm formation (DflgK-lux). PJI development and biofilm formation was quantitatively assessed in vivo using the in vivo imaging system (IVIS), and in vitro using the viable colony count of the bacterial load on implant surface. Magnetic Resonance Imaging (MRI) was acquired to assess the involvement of periprosthetic tissue in vivo, and the field emission scanning electron microscopy (FE-SEM) of the explanted implants was used to visualize the biofilm formation at the bone-implant interface. The implant stability, as an outcome, was directly assessed by quantifying the osseointegration using microCT scans of the extracted femurs with retained implants in vitro, and indirectly assessed by identifying the gait pattern changes using DigiGaitTM system in vivo. A localized prosthetic infection was reliably established within the hip joint and was followed by IVIS in real-time. There was a quantitative and qualitative difference in the bacterial load and biofilm formation between PA14 and DflgK. This difference in the ability to persist in the model between the two strains was reflected on the gait pattern and implant osseointegration. We developed a novel uncemented hip hemiarthroplasty GN-PJI rat model. This model is clinically representative since animals can bear weight on the implant. PJI was detected by various modalities. In addition, biofilm formation correlated with implant function and stability. In conclusion, the proposed in vivo GN-PJI model will allow for more reliable testing of novel biofilm-targeting therapetics
Prosthetic joint infection (PJI) is a complex disease that causes significant damage to the peri-implant tissue. Developing an animal model that is clinically relevant in depicting this disease process is an important step towards developing novel successful therapies. In this study, we have performed a thorough histologic analysis of peri-implant tissue harvested post Staphylococcus aureus (S. aureus) infection of a cemented 3D-printed titanium hip implant in rats. Sprague-Dawley rats underwent left hip cemented 3D-printed titanium hemiarthroplasty via posterior approach under general anesthesia. Four surgeries were performed for the control group and another four for the infected group. The hip joint was inoculated with 5×109 CFU/mL of The histologic analysis revealed strong resemblance to tissue changes in the clinical setting of chronic PJI. IHC demonstrated the extent of bacterial spread within the peri-implant tissue away from the site of infection. The H&E and MT stains showed 5 main features in infected bone: 1) increased PMNs, 2) fibrovascular inflammation, 3) bone necrosis, and 4) increased osteoclasts 5) fibrosis of muscular tissue and cartilage. Micro CT data showed significantly more osteolysis present around the infected prosthesis compared to control (surgery with no infection). This is the first clinically relevant PJI animal model with detailed histologic analysis that strongly resembles the clinical tissue pathology of chronic PJI. This model can provide a better understanding of how various PJI therapies can halt or reverse peri-implant tissue damage caused by infection.
Gram-negative prosthetic joint infections (GN-PJI) present unique challenges in management due to their distinct pathogenesis of biofilm formation on implant surfaces. The purpose of this study is to establish a clinically representative GN-PJI model that can reliably recapitulate biofilm formation on titanium implant surface The model was developed using 3D-printed titanium hip implants, to replace the femoral head of male Sprague-Dawley rats. GN-PJI was induced using two bioluminescent Introduction
Methods
The aims of this study were to develop an in vivo model of periprosthetic joint infection (PJI) in cemented hip hemiarthroplasty, and to monitor infection and biofilm formation in real-time. Sprague-Dawley rats underwent cemented hip hemiarthroplasty via the posterior approach with pre- and postoperative gait assessments. Infection with Aims
Methods
We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon. We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed.Aims
Methods
Hip dysplasia has traditionally been classified based on the lateral centre edge angle (LCEA). A recent meta-analysis demonstrated no definite consensus and a significant heterogeneity in LCEA values used in various studies to define hip dysplasia and borderline dysplasia. To overcome the shortcomings of classifying hip dysplasia based on just LCEA, a comprehensive classification for adult acetabular dysplasia (CCAD) was proposed to classify symptomatic hips into three discrete prototypical patterns of hip instability, lateral/global, anterior, or posterior. The purpose of this study was to assess the reliability of this recently published CCAD. One thirty four consecutive hips that underwent a PAO were categorized using a validated software (Hip2Norm) into four categories of normal, lateral/global, anterior or psosterior. Based on the prevalence of individual dysplasia and using KappaSize R package version 1.1, seventy four cases were necessary for reliability analysis: 44 dysplastic and 30 normal hips were randomly selected. Six blinded fellowship trained raters were then provided with the classification system and they looked at the x-rays (74 images) at two separate time points (minimum two weeks apart) to classify the hips using standard PACS measurements. Thereafter, a consensus meeting was held where a simplified flow diagram was devised before a third reading by four raters using a separate set of 74 radiographs took place. Intra-rater results per surgeon between Time 1 and Time 2 showed substantial to almost perfect agreement amongst the raters. With respect to inter-rater reliability, at time 1 and time 2, there was substantial agreement overall between all surgeons (kappa of 0.619 for time 1 and 0,623 for time 2). Posterior and anterior rating categories had moderate and fair agreement at time 1 and time 2, respectively. At time 3, overall reliability (kappa of 0.687) and posterior and anterior rating improved from Time 1 and Time 2. The comprehensive classification system provides a reliable way to identify three categories of acetabular dysplasia that are well-aligned with surgical management. The term borderline dysplasia should no longer be used.
The aim of the current study was to assess the reliability of the Ottawa classification for symptomatic acetabular dysplasia. In all, 134 consecutive hips that underwent periacetabular osteotomy were categorized using a validated software (Hip2Norm) into four categories of normal, lateral/global, anterior, or posterior. A total of 74 cases were selected for reliability analysis, and these included 44 dysplastic and 30 normal hips. A group of six blinded fellowship-trained raters, provided with the classification system, looked at these radiographs at two separate timepoints to classify the hips using standard radiological measurements. Thereafter, a consensus meeting was held where a modified flow diagram was devised, before a third reading by four raters using a separate set of 74 radiographs took place.Aims
Methods
Calcium sulphate has traditionally been used as a filler of dead space arising during surgery. Various complications have been described following the use of Stimulan bio-absorbable calcium sulphate beads. This study is a prospective observational study to assess the safety profile of these beads when used in revision arthroplasty, comparing the complication rates with those reported in the literature. A total of 755 patients who underwent 456 revision total knee arthroplasties (TKA) and 299 revision total hip arthroplasties (THA), with a mean follow-up of 35 months (0 to 78) were included in the study.Aims
Methods
The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results to prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (MAT and MAI) from 5/30/2013 to 12/29/2015 were identified and included in the study. Retrospective chart and radiograph review was performed on nineteen patients, eleven male and eight female, with mean age of 47.83 years (22–82). No patients were excluded from the study.Purpose
Methods
The current study aimed to determine the influence of acetabular coverage and intraarticular pathology on post-operative functional outcomes of arthroscopy for cam type FAI. Based on 762 hip scopes performed by a single surgeon between 2013 and 2016, we excluded patients with previous surgery on the hip, mixed FAI, surgical hip dislocation, and missing outcome scores. From this, 97 hips between the ages 17 and 48 that underwent arthroscopy for cam deformity were identified for analysis. Every patient received a partial capsulotomy, cam resection and either labral repair or resection. Measurements for acetabular coverage consisted of pre-operative lateral edge angle (LCEA) (mean 30°, range: 15.4°–40°) and three-dimensional anterior and posterior acetabular coverages. Intraoperative Beck scores were acquired from operative reports, and Hip Disability and Osteoarthritis Outcome Score (HOOS) was collected pre- and post-operatively. Significant post-operative improvement was found in scores of all categories of the HOOS (p < 0.05). However, improvement in HOOS was not correlated with the LCEA, anterior coverage, or posterior coverage. There was a trend toward lower Beck grades (1–3) resulting in better HOOS outcomes than higher Beck grades (4–5). Also, lower Beck grades showed significantly lower alpha angle (mean = 55.86) than higher grades (mean = 73.48). We showed that cam FAI arthroscopic resection improved patient outcome, and confirmed the relationship between the Beck score and functional outcome. However, functional improvement was not related to acetabular coverage suggesting that the so-called “borderline” dysplasia is not a useful radiographic indicator for surgical management.
Periprosthetic joint infection (PJI) remains a challenging complication following Total Hip Arthroplasty (THA). It is associated with high levels of morbidity, mortality and is time consuming and expensive to treat. Our management generally relies on identification of the infecting organism(s) in order to define the appropriate treatment strategy. Patients with culture-negative PJI poses a greater challenge to surgeons and to the wider multidisciplinary team. This study compares the outcomes of 50 consecutive complex culture-positive (deemed unsuitable for single stage exchange) and 50 culture-negative THAs managed with two-stage revision arthroplasty with a minimum of five years follow-up. Culture-negative PJIs were associated with older age, smoking, external referral source and greater use of preoperative antibiotics. There was however no significant difference in outcome between these groups of patients with a similar complication rates and reinfection rates of 6% at 5 years. Culture negative periprosthetic sepsis generates concern, and is often considered a poor prognostic indicator. This study suggests that a strict 2 stage protocol is associated with satisfactory outcomes in such cases.
Revision surgery for total knee replacement is a complex procedure, carrying an increased risk for the patient and cost for hospitals. As well as increased cost of peri-operative investigations, blood transfusions, surgical instrumentation, implants and theatre time, there is a well documented increased length of stay (LOS), accounting for the majority of actual costs associated with surgery. We compared revision surgery for infection vs. other causes (aseptic loosening, dislocation, mal-alignment). Clinical, demographic and economic data were obtained for 180 consecutive revision total knee replacements performed at a tertiary referral centre between 2003 and 2012. Actual costs and National Health Service tariffs were compared per patient and mean difference calculated. Mean age was 66 years (range 17–87) with 62 male and 117 female patients. Mean LOS for aseptic cases was 10 days (range 1–62) and 20 days (range 4–103) for infection. Mean cost difference in aseptic cases (n = 125) was £−933 (SD = £12,204), and £−3907 (SD = £7,256) for infection (n = 54). Surgery for infection was associated with increased operating times, blood loss and complications compared to revision for aseptic causes. LOS for infection was on average double that for aseptic cases (p < 0.05). Current NHS tariffs do not fully reimburse the increased costs associated with providing a revision knee surgery service, with even greater cost incurred by the treating hospital for infected cases. These losses may negatively influence the provision of revision surgery in the NHS.
Flexor tendon injuries of the hand are common with an incidence of over 3000 per annum in the UK. These injuries can affect hand function significantly. Early treatment with optimal repair is crucial to prevent disability. This study aimed at investigating the re-rupture rate following primary flexor tendon repair at our institution and to identify potential risk factors for re-rupture. 100 flexor tendons' injuries that underwent primary repair over a one-year period were reviewed retrospectively. Data was collected on age, gender, occupation, co morbidities, injured fingers, hand dominance, smoking status, zone of injury, time to surgery, surgeon grade, type of repair and suture, and antibiotic use on included patients. Causes of re-rupture were examined. We compared primary tendon repairs that had a re-rupture to those that did not re-rupture. Univariate and multivariate analysis was undertaken to identify the most significant risk factors for re-rupture.Introduction/Aim
Methods
Anterior cruciate ligament (ACL) rupture is a common sporting injury, often managed surgically with patella-tendon or hamstrings autograft. Surgeons are under increasing pressure for open transparent assessment of their performance. Scoring systems can be used to assess outcome. More than 50 different scoring systems have been identified to assess the ACL deficient knee. The survey is investigating the use of ACL scoring systems between knee surgeons in the United Kingdom as a method of assessing performance.Introduction
Aims
Trauma is the leading cause of death and disability in children. Pelvic fractures although rare, with a reported incidence of one per 100,000 children per year are 2nd only to skull fractures with respect to morbidity. The objectives of this study were to improve understanding of paediatric pelvic fractures through a concise review of all aspects of these fractures and associated injuries. Understanding the patterns in which paediatric pelvic fractures and their associated injuries occur and the outcome of treatment is vital to the establishment of effective preventative, diagnostic and therapeutic interventions. All children admitted to our unit with a pelvic fracture over the 14-year period from January 1995 to December 2008 were identified. The complete medical records and radiographs of all patients were obtained and reviewed. Data recorded included, age, sex, mechanism of injury, Glasgow Coma Score, Injury Severity Score, fracture type, radiological investigation, length of in-patient stay, length of intensive care unit stay, blood transfusion requirement, associated injuries, management (both orthopaedic and non-orthopaedic), length of follow-up, and outcomeIntroduction
Patients and Methods
In all 35 patients (29 male) underwent surgery for significant fracture displacement with shortening, manual workers and keen sportsmen at the time of injury. The infraclavicular approach was used in 21 patients and 14 patients had direct incision approach. Radiological union was achieved in all patients after an average of 13.26(8–24) weeks. Six patients required plate removal at 6 months following surgery, infraclavicular (2 patients) &
direct approach (4 patients). All patients returned to their original occupation at average 2.55 months. The Oxford Shoulder Score at 3 months after surgery was average 15 (range12–20) and all patients, except one, scored excellent on subjective scoring.
Clavicle fracture account for about 44% of all adult fracture around the shoulder, although non-operative care results in high union rates for most, surgery is indicated in particular if displacement and/or shortening greater than 15–20 mm, lack of cortical apposition in young, healthy, active individual to yield the best clinical results in terms of alignment, union and early mobilisation. We did a retrospective audit to define the guidelines for admission, safer surgical approach and functional outcome using oxford score for the period Jan2002–Jan2007. This included 35pts, with Female: male ratio 1:2.5, Right: left side of 12:23, just over 50%were manual labours. Most common indication for surgery was displacement/shortening (16pts). 28 pts were operated within 4 weeks as acute admission. Direct incision was used in 14pts and infraclavicular incision in 21pts. Radiological union were seen in all pts on average 13.26 weeks (8 – 24wks). 10 patients had minor complications, 28% with direct incision and 19% with infraclavicular approach 29 patients went back to original work by 2.55 month, 5 excluded as 3 were at school, 2 unemployed and 1 did not mention. All patients had an oxford score of 12–20, showing satisfactory joint function. Metal work were removed in 6 patients, 2 (9.5%) in infraclavicular and 4 (28%) in direct incision.