Despite the rise of back pain disability, objective mechanical assessment is generally lacking. Quantification of intervertebral kinematics using fluoroscopy provides objective measurement, but its use in clinical practice has not been assessed. This study reviewed cases referred to one UK site for lumbar spine quantitative fluoroscopic (QF) examinations and compared the reasons for referral with the findings reported. Fifty-seven consecutive referrals were reviewed. Patients underwent passive recumbent and/or weight-bearing active examinations in either the sagittal or both the sagittal and coronal planes. Data were extracted from anonymised QF reports and analysed for patient characteristics, reason for referral, working diagnosis at referral, level(s) of interest, previous surgical procedures and findings reported. Reports were also thematically analysed for key findings. Most patients had chronic back conditions of moderate or severe intensity. Most (38/57) were male, mean age 47 (SD 13.1) and mean complaint duration 5.4 years (0.3–32 years). They were referred mainly to investigate segmental instability (19/54) or spondylolisthesis (13/54) to inform either surgical referral or conservative management. Instability was reported in only 8/57 cases, but restricted and hypermobile levels in the same patient was also common (13/57). In 11 cases no mechanical abnormality was found.Purpose and Background:
Methods and Results:
It was noted that in our spinal theatre a constant cause of delay was lack of an available radiographer. This work describes our solution to this problem by training theatre staff to operate the imaging equipment for the simple single plane images required in spinal surgery. Under the guidance of the trust's Radiation Protection Advisor to a training program for theatre staff was devised that encompassed the practical aspects of using the imaging equipment and the theoretical elements of radiation safety. All changes in practice complied with the radiation safety regulations IRR 99 and IRMER 2000. The trained staff now work as independent operators in the spinal theatre. They work to a ridge protocol and have to report directly to a Radiation Protection Supervisor (senior radiographer) at the end of each list so that the images taken and radiation dosage can be verified. Since the change of practice, the spinal theatre has been more efficient, performing up to one major case extra per list. The radiology department has benefited by having a radiographer freed to perform more complex procedures elsewhere. The operators have also commented on how they have found the whole process rewarding both professionally and personally. The training of theatre staff to operate the imaging equipment in our spinal theatre has been a successful endeavour and at present the trust is currently planning to expand the program to include other surgical fields such as urology and laparoscopic surgery.