header advert
Results 1 - 3 of 3
Results per page:

Aims

To compare time dependent functional improvement for patients with medial, respectively lateral knee osteoarthritis (OA) after treatment with opening wedge osteotomy relieving the pressure on the osteoarthritic part of the knee.

Methods

In all, 49 patients (52 knees) with a mean age of 47 years (31 to 64) underwent high tibial osteotomies (HTO), and 24 patients with a mean age of 48 years (31 to 62) low femoral osteotomies (LFO) with opening wedge technique due to medial, respectively lateral knee OA with malalignment. All osteotomies were stabilized with a Puddu plate and bone grafting performed in the same time period (2000 to 2008). The patients were evaluated by the Knee Injury and Osteoarthritis Outcome Score (KOOS) pre-operatively and at six months, and at one, two, five, and ten years postoperatively. The knee OA was graded according to the Ahlbäck and Kellgren-Lawrence radiological scoring systems.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1157 - 1166
1 Sep 2017
Nerhus TK Ekeland A Solberg G Olsen BH Madsen JE Heir S

Aims

The aim of this prospective randomised study was to compare the time course of clinical improvement during the first two years following a closing or opening wedge high tibial osteotomy (HTO). It was hypothesised that there would be no differences in clinical outcome between the two techniques.

Patients and Methods

Between 2007 and 2013, 70 consecutive patients were randomly allocated to undergo either a closing or opening wedge HTO. All patients had medial compartment osteoarthritis (OA), and were aged between 30 years and 60 years. They were evaluated by independent investigators pre-operatively and at three and six months, and one and two years post-operatively using the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Oxford Knee Score (OKS), the Lysholm score, the Tegner activity score, the University of California, Los Angeles (UCLA) activity scale and range of movement (ROM).


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 97 - 97
1 Mar 2006
Ekeland A Heir S Dimmen S Nerhus K
Full Access

Introduction: The operational technique for opening wedge osteotomies has been simplified by the use of the Puddu-plate. This study presents results after use of Puddu-plates on distal femoral and proximal tibial osteotomies.

Methods: Fifteen distal femoral and 25 proximal tibial osteotomies have been performed with opening wedge technique due to knee osteoarthritis with malalignment in the period 2000–2004. The knee osteoarthritis was mainly due to a previous meniscal extirpation. Ten patients had an additional rupture of the anterior cruciate ligament. The mean age of the patients was 49 years (31–66 years), and 17 females and 23 males were operated. The patients with femoral osteotomies had a mean preoperative tibiofemoral valgus angle of 12° (8°–20°) whereas those with tibial osteotomies had a mean tibiofemora varus angel of 1° (7° varus – 3° valgus). The osteotomy was fixed with a Puddu-plate securing the planned angular correction, and the osteotomy cleft was filled by autogenous pelvic bone. The mean follow-up time was 18 months (3–42 months).

Results: The width of the osteotomy cleft was determined by the tooth of the implant. The mean width of the tooth was 8.6 mm (5–12.5 mm), and the mean angular correction measured on pre- and postoperative radiographs was 8.4° (5–15°). The osteotomy cleft healed after a mean of 13 weeks (7–26 weeks). One patient suffered venous thrombosis of the leg and one a postoperative wound infection. The knee injury and osteoarthritis outcome score (KOOS) increased significantly during the observation period. For pain the mean preoperative score was 53 and the score at follow-up was 82. The corresponding scores for symptoms were 56 and 75, for activity of daily life (ADL) 65 and 86, for sport and recreation 26 and 52 and for quality of life 33 and 64 (P< 0.001).

Conclusion: The results after opening wedge osteotomy using the Puddu-plate seem satisfactory. The operational technique is simpler compared to previous methods, and the degree of angular correction is accurate depending on the width of the tooth of the implant which in mm corresponds relatively well with the degrees of angular correction.