Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls.
Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant between 2011–2017 at three European and seven US sites. Of 2,003 (97.3%) TKAs in 1,644 patients with BMI data: average age 64.5 years; 58.4% females; average BMI 32.5 kg/m2; 13.4% had BMI ≥ 40 kg/m2. Subjects with BMI ≥ 40 kg/m2 had longest length of hospital stay (LOS) at European sites; LOS similar at US sites. Subjects with BMI ≥ 40 kg/m2 (P=0.0349) had longest surgery duration. BMI ≥ 40 kg/m2 had more re-hospitalizations or post-TKA reoperations than BMI < 40 kg/m2 (12.7% and 9.2% at five-year post-TKA, P<0.0495). Surgery duration and long-term complication rates are higher in patients with BMI ≥ 40 kg/m2, but device revision risk is not elevated.
Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant (Journey II Bi-Cruciate Stabilized Knee System, Smith & Nephew, Inc., Memphis) were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data.Introduction
Materials and Methods
Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant (Journey II Bi-Cruciate Stabilized Knee System, Smith & Nephew, Inc., Memphis) between 2011–2017 at three European and seven US sites.Introduction/Aim
Materials and Methods
A technical goal in total knee arthroplasty is the production of a neutral coronal plane mechanical axis. Errors may produce large mechanical axis deviations precipitating early implant failure. This study sought to test if measured distal femoral resection produced more accurate and consistent coronal alignment than arbitrarily set distal femoral resection. Data from a cohort of 255 consecutive unselected primary total knee arthroplasties undertaken by the senior author (PM) was collected prospectively and independently assessed. In the first 167 cases distal femoral resection was arbitrarily set to 5 degrees of valgus. In the remaining 88 cases the distal femoral resection angle was determined on a preoperative long leg standing AP radiograph. Postoperative coronal alignment was measured on long leg standing AP radiograph in all cases. The measured distal femoral valgus angle was between 4 and 7 degrees. An equal number measured either 5 or 6 degrees and accounted for 85% of the total number. Statistically insignificant improvements in mean axis and standard deviation were observed in the measured group: mean axis deviation −0.31 vs −0.51: p=0.17 (independent samples t test) and standard deviation 0.91 vs 1.09: p=0.055 (Levene test). Acceptable coronal alignment in total knee arthroplasty can reliably be obtained with conventional instrumentation. Improvement in standard deviation with measured distal femoral valgus angle approaches statistical significance.