1 Dec 2014
Keetse MM Phaff M Rollinson P Hardcastle T
Full Access

Background:

There is limited evidence regarding HIV infection as a risk factor for delayed union and implants sepsis in patient with fractures treated with surgical fixation. Most studies have included patient with a variety of different fractures and hence very different risks regarding delayed union and implant sepsis. We have looked at a single fracture, closed femoral shaft fractures treated with intramedullary nailing, to see if HIV infection is a risk factor with for the development of delayed union and implant sepsis. We present a prospective study of 160 patients with closed femoral shaft fractures treated with intramedullary nailing. Primary outcomes were delayed union of more than 6 months and implant sepsis in the first 12 months.

Methods:

From February 2011 until November 2012 all patient with closed femoral shaft fractures treated at our hospital were included in the study. Patients were tested for HIV infection and a number of clinical parameters were documented, including: AO fracture score, duration of surgery, level of training of surgeon, comorbidities, CD4 count, high energy injury and number of operations.