Advertisement for orthosearch.org.uk
Results 1 - 20 of 34
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans.

Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively.

Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT.

The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 66 - 66
1 May 2019
Haidukewych G
Full Access

Peri-prosthetic fractures above a TKA are becoming increasingly more common, and typically occur at the junction of the anterior flange of the femoral component and the osteopenic metaphyseal distal femur. In the vast majority of cases, the TKA is well fixed and has been functioning well prior to fracture. For fractures above well-fixed components, internal fixation is preferred. Fixation options include retrograde nailing or lateral plating. Nails are typically considered in arthroplasties that allow intercondylar access (“open box PS” or CR implants) and have sufficient length of the distal fragment to allow multiple locking screws to be used. This situation is rare, as most distal fragments are quite short. If a nail is chosen, use of a long nail is preferred, since it allows the additional fixation and alignment that diaphyseal fill affords. Short nails should be discouraged since they can “toggle” in the meta-diaphysis and do not engage the diaphysis to improve coronal alignment. Plates can be used with any implant type and any length of distal fragment. The challenge with either fixation strategy is obtaining stable fixation of the distal fragment while maintaining length, alignment, and rotation. Fixation opportunities in the distal fragment can be limited due to obstacles caused by femoral component lugs, boxes, stems, cement mantles, and areas of stress shielding or osteolysis. Modern lateral locked plates can be inserted in a biologically friendly submuscular extra-periosteal fashion. The goal of fixation is to obtain as many long locked screws in the distal fragment as possible. High union rates have been reported with modern locked plating and nailing techniques, however, biplanar fluoroscopic vigilance is required to prevent malalignments, typically valgus, distraction, and distal fragment hyperextension.

For certain fractures, distal femoral replacement (DFR) is a wise choice. The author reserves DFR for situations where internal fixation is likely to fail (severe distal osteolysis, severe osteopenia) or for cases where it has already failed (nonunion). Obviously, if the implant is loose, revision is indicated, and typically the distal bone loss is so severe that a distal femoral replacement is indicated. The author prefers cemented constructs and routinely adds antibiotics to the cement mixture. Careful attention to posterior dissection of the distal fragment is recommended to avoid neurovascular injury. Cementing the femoral component in the proper amount of external rotation is important to allow central patellar tracking. The available literature demonstrates excellent functional results with these reconstructions, however, complications are not uncommon. Infection and extensor mechanism complications are the most frequent complications and are best avoided.

In summary, ORIF remains the treatment of choice for these fractures, however, for cases where ORIF is likely to fail, or has failed, DFR remains a predictable salvage option.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 108 - 108
1 May 2019
Haidukewych G
Full Access

Uncemented acetabular component fixation remains the gold standard for managing various defects in the revision hip setting. Multiple series have demonstrated over 90% ten-year survivorship of these constructs. Modern “enhanced” metals such as trabecular tantalum and titanium continue to perform well and are growing in popularity. So called “jumbo” cups, diameters >=62mm in females and >=66mm in males have demonstrated excellent survivorship. Good bony support with viable bone and stable initial fixation is necessary for long-term success. It is unknown how much remaining bone is necessary for reliable ingrowth with modern enhanced metals. The location of the remaining bone is probably more important than the absolute amount remaining. Occasionally, the uncemented cup must be augmented with metal augments or even a so-called “cup cage” construct. Even in these situations, the uncemented cup remains the workhorse of revision THA due to its ingrowth potential and excellent track record. Augments are commercially available in various shapes and sizes to assist in the management of cavitary, segmental and combined defects while restoring the desired cup position. Trials are available to ensure good approximation of the augment to remaining bone. The constructs are typically “unitised” to the cup via bone cement. Available data show excellent survivorship of augmented constructs for these challenging reconstructions.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 52 - 52
1 Oct 2018
Parry J Langford J Koval K Haidukewych G
Full Access

Introduction

The vast majority of intertrochanteric fractures treated with cephalomedullary nails (CMN) will heal. Occasionally even though bony union occurs excessive lag screw sliding can cause persistent pain and soft tissue irritation and return to surgery for hardware removal. The purpose of this study was to evaluate if fracture stability, lag screw tip-apex distance (TAD), and quality of reduction have any impact excessive lag screw sliding and potential cutout.

Methods

As part of our level one trauma center's institutional hip fracture registry, a retrospective analysis identified 199 intertrochanteric fractures fixed with CMN between 2009 and 2015 with follow up to union or a minimum of three months. The mean follow-up was 22 months (3 to 94 months). Mean patient age was 75 years (50 to 97 years) and 72% were women. Postoperative radiographs were used to measure the TAD, quality of reduction, neck-shaft angle (NSA), and lateral lag screw prominence. Follow-up radiographs were reviewed to assess fracture union, translation, and progression of lateral lag screw prominence. Complications and reoperations were recorded.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 66 - 66
1 Jun 2018
Haidukewych G
Full Access

Uncemented acetabular component fixation remains the gold standard for managing various defects in the revision hip setting. Multiple series have demonstrated over 90% ten-year survivorship of these constructs. Modern “enhanced” metals such as trabecular tantalum and titanium continue to perform well and are growing in popularity. So called “jumbo” cups, diameters >=62mm in females and >=66mm in males have demonstrated excellent survivorship. Good bony support with viable bone and stable initial fixation is necessary for long-term success. It is unknown how much remaining bone is necessary for reliable ingrowth with modern enhanced metals. The location of the remaining bone is probably more important than the absolute amount remaining. Occasionally, the uncemented cup must be augmented with metal augments or even a so-called “cup cage” construct. Even in these situations, the uncemented cup remains the workhorse of revision THA due to its ingrowth potential and excellent track record. Augments are commercially available in various shapes and sizes to assist in the management of cavitary, segmental and combined defects while restoring the desired cup position. Trials are available to ensure good approximation of the augment to remaining bone. The constructs are typically “unitised” to the cup via bone cement. Available data show excellent survivorship of augmented constructs for these challenging reconstructions.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 15 - 15
1 Jun 2018
Haidukewych G
Full Access

Few will disagree that the best femoral head that a young patient can have is his or her own, native femoral head. In the active, healthy patient under age 60 with a displaced femoral neck fracture, well-done, timely ORIF presents the best chance of preserving the patient's native femoral head. Arthroplasty is generally reserved for older patients, over age 60, where attempts at ORIF in this setting have demonstrated failure rates over 40%. “Physiologic age” is a somewhat nebulous term that takes into account the health and ambulatory status of the patient. For example, a 52-year-old with end-stage renal failure, severe osteoporosis, and a displaced femoral neck fracture may best be treated with arthroplasty. However, in reality, such situations are quite rare. Recent studies have documented that approximately 80% of young patients with displaced femoral neck fractures treated with ORIF will keep their own femoral head for 10 years after injury. The variables under the surgeon's control include timing of fixation, quality of reduction, accurate implant placement and implant selection, and capsulotomy. All of these variables potentially affect outcomes. Fractures in this young age group are frequently high shear angle (vertical) Pauwels type 3 fractures, and benefit from fixed angle fixation. The author prefers anatomic reduction and stabilization with a sliding hip screw and a superiorly placed derotation screw. Careful attention to detail is important to obtain an anatomic reduction, which is the most important variable in the outcome of these challenging injuries.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 82 - 82
1 Jun 2018
Haidukewych G
Full Access

The vast majority of fractures around the knee will heal with well-done internal fixation. TKA has a role in several scenarios. Acute TKA can be effective for fractures of the distal femur (especially periprosthetic) in very elderly patients where internal fixation attempts are likely to fail. Acute TKA for tibia plateau fractures may have a role in fractures in the elderly with pre-existing DJD and relatively simple fracture patterns. There is very little published literature regarding the outcomes of TKA for acute tibial plateau fracture and caution is advised until more data is available. TKA is commonly indicated for failed fixation and post-traumatic arthritis. Challenges include managing retained hardware, soft tissue injury and contracture, unusual ligamentous imbalances, and multiple prior incisions and/or flaps. Occasionally, a partial hardware removal may be appropriate. If extensive or multiple incisions are needed for hardware removal it may be wise to stage the reconstruction after soft tissue recovery. The available data on TKA for post-traumatic reconstructions generally demonstrate predictable functional improvement but higher complications.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 5 - 5
1 Jan 2018
Haidukewych G Shekailo P Yoon R
Full Access

There is a paucity of available literature to guide the surgeon treating postoperative fractures of the greater trochanter after femoral component revision. Between 2009 and 2016, 133 patients underwent femoral component revision by the senior author utilizing a modular tapered fluted titanium stem. 17 patients died or had inadequate follow-up. Therefore, 116 patients were included in the final analysis. There were 58 males and 58 females with a mean age of 64 (range 23 to 91 years old). Clinical and radiographic data were analyzed for postoperative greater trochanteric fracture (GTfx). Mean clinical follow up was 21 months (range 3 to 77 mos). Age, BMI, preoperative diagnosis, comorbidities, reason for revision, use of Extended Trochanteric Osteotomy (ETO), fixation method of ETO, presence of prior hardware, post-operative trauma (falls), femoral component size and offset, change in leg length were analyzed to determine potential risk factors for postoperative GT fracture.

There were 7 postoperative greater trochanteric fractures in 7 patients (6%). Of these, 1 occurred as a result of a postoperative fall, 1 occurred after dislocation, and 1 occurred after a fall with a subsequent dislocation. The mean time to diagnosis of the fracture was 10.7 weeks postoperatively (range one day to 37.4 weeks). 52 of 116 patients had their revision performed through an ETO. Of those, 6 had a postoperative fracture of the GT. The use of an ETO significantly increased the likelihood of postoperative GT fx (p=0.035). Regarding femoral component size, use of a longer proximal body (+10 or greater) was associated with an increased risk of postoperative GT fx (p=0.07).

Two fractures were minimally (<1cm) or non-displaced and were treated non-operatively. Of these fractures, 1 united. The other fracture further displaced and resulted in recurrent instability. This was treated with excision of the fragment and a constrained liner. 5 fractures were displaced and were treated with ORIF. 3 were fixed with a cable grip device, 1 was plated, and 1 was treated with a cable grip device and a constrained liner. Of those treated with some form of ORIF, all 5 healed. Of those that underwent surgical fixation initially, 3 reported residual trochanteric pain and 1 patient had their hardware removed (trochanteric claw). 2 of these patients have a residual limp and require a cane for use as a gait aid. The patient treated non-surgically required a cane as did the patient that failed non-surgical treatment.

Post-operative greater trochanteric fractures are a rare complication of femoral component revision. The use of an ETO significantly increased the rate of post of GTfx. The mean time to diagnosis of was 11 weeks. Displaced fractures of the greater trochanter treated with ORIF all healed, both cable grip devices and plates were effective. Residual limp requiring gait aids and residual trochanteric pain were common outcomes after fixation of these fractures despite successful union.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 85 - 85
1 Aug 2017
Haidukewych G
Full Access

Few will disagree that the best femoral head that a young patient can have is his or her own, native femoral head. In the active, healthy patient under age 60 with a displaced femoral neck fracture, well-done, timely ORIF presents the best chance of preserving the patient's native femoral head. Arthroplasty is generally reserved for older patients, over age 60, where attempts at ORIF in this setting have demonstrated failure rates over 40%. “Physiologic age” is a somewhat nebulous term that takes into account the health and ambulatory status of the patient. For example, a 52-year-old with end stage renal failure, severe osteoporosis, and a displaced femoral neck fracture may best be treated with arthroplasty. However, in reality, such situations are quite rare. Recent studies have documented that approximately 80% of young patients with displaced femoral neck fractures treated with ORIF will keep their own femoral head for 10 years after injury. The variables under the surgeon's control include timing of fixation, quality of reduction, accurate implant placement and implant selection, and capsulotomy. All of these variables potentially affect outcomes. Fractures in this young age group are frequently high shear angle (vertical) Pauwels Type 3 fractures, and benefit from fixed angle fixation. The author prefers anatomic reduction and stabilisation with a sliding hip screw and a superiorly placed derotation screw. Careful attention to detail is important to obtain an anatomic reduction, which is the most important variable in the outcome of these challenging injuries.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 66 - 66
1 Aug 2017
Haidukewych G
Full Access

There are many challenges facing the revision knee surgeon. Bony defects, ligamentous imbalance, and difficult gap balancing scenarios are common and require practical management strategies. Typically, an implant with the least amount of constraint necessary to provide a well-aligned, well-balanced arc of motion is preferred. Constraint in implants increases the stresses on both the bearing surfaces and the bony interfaces and may result in earlier mechanical failure of the implant. Despite this fact, there are situations where one cannot rely on a simple larger polyethylene post (such as found in CCK type devices) to balance gaps. The author prefers to choose hinge-type devices in situations that demonstrate massive gap imbalance (typically huge flexion gaps), situations with deficient extensor mechanisms that can result in recurvatum stresses, or in situations of global ligamentous instability. Techniques of supporting the bony interfaces with stems and sleeves may improve the longevity of these constructs. Complications are common, including extensor mechanism problems. Multiple studies have demonstrated reasonable results of hinged implants for these challenging revision scenarios, and the hinge should remain in the armamentarium of the revision surgeon.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 100 - 100
1 Apr 2017
Haidukewych G
Full Access

Peri-prosthetic fractures above a TKA are becoming increasingly more common, and typically occur at the junction of the anterior flange of the femoral component and the osteopenic metaphyseal distal femur. In the vast majority of cases the TKA is well fixed and has been functioning well prior to fracture. For loose components, revision is typically indicated. Typically a megaprosthesis is required. Well-fixed components, internal fixation is preferred. Fixation options include retrograde nailing or lateral plating. Nails are typically considered in arthroplasties that allow intercondylar access (“open box PS” or CR implants) and have sufficient length of the distal fragment to allow multiple locking screws to be used. This situation is rare, as most distal fragments are quite short. If a nail is chosen, use of a long nail is preferred, since it allows the additional fixation and alignment that diaphyseal fill affords. Short nails should be discouraged since they can “toggle” in the meta-diaphysis and do not engage the diaphysis to improve coronal alignment. Plates can be used with any implant type and any length of distal fragment. The challenge with either fixation strategy is obtaining stable fixation of the distal fragment while maintaining length, alignment, and rotation. Fixation opportunities in the distal fragment can be limited due to obstacles caused by femoral component lugs, boxes, stems, cement mantles, and areas of stress shielding or osteolysis. Modern lateral locked plates can be inserted in a biologically friendly submuscular extra-periosteal fashion. More recent developments with polyaxial locked screws (that allow angulation prior to end-point locking) may offer even more versatility when distal fragment fixation is challenging. The goal of fixation is to obtain as many long locked screws in the distal fragment as possible. High union rates have been reported with modern locked plating techniques, however, biplanar fluoroscopic vigilance is required to prevent malalignments, typically valgus, distraction, and distal fragment hyperextension.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 113 - 113
1 Apr 2017
Haidukewych G
Full Access

There are many challenges facing the revision knee surgeon. Bony defects, ligamentous imbalance, and difficult gap balancing scenarios are common and require practical management strategies. Typically, am implant with the least amount of constraint necessary to provide a well-aligned, well-balanced arc of motion is preferred. Constraint in implants increases the stresses on both the bearing surfaces and the bony interfaces and may result in earlier mechanical failure of the implant. Despite this fact, there are situations where one cannot rely on a simple larger polyethylene post (such as found in CCK type devices) to balance gaps. The author prefers to choose hinge type devices in situations that demonstrate massive gap imbalance (typically huge flexion gaps), situations with deficient extensor mechanisms that can result in recurvatum stresses, or in situations of global ligamentous instability. Techniques of supporting the bony interfaces with stems and sleeves may improve the longevity of these constructs. Complications are common, including extensor mechanism problems. Multiple studies have demonstrated reasonable results of hinged implants for these challenging revision scenarios, and the hinge should remain in the armamentarium of the revision surgeon.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 15 - 15
1 Apr 2017
Haidukewych G
Full Access

Few will disagree that the best femoral head that a young patient can have is his or her own, native femoral head. In the active, healthy patient under age 60 with a displaced femoral neck fracture, well-done, timely ORIF presents the best chance of preserving the patient's native femoral head. Arthroplasty is generally reserved for older patients, over age 60, where attempts at ORIF in this setting have demonstrated failure rates over 40%. “Physiologic age” is a somewhat nebulous term that takes into account the health and ambulatory status of the patient. For example, a 52-year-old with end stage renal failure, severe osteoporosis, and a displaced femoral neck fracture may best be treated with arthroplasty. However, in reality, such situations are quite rare. Recent studies have documented that approximately 80% of young patients with displaced femoral neck fractures treated with ORIF will keep their own femoral head for 10 years after injury. The variables under the surgeon's control include timing of fixation, quality of reduction, accurate implant placement and implant selection, and capsulotomy. All of these variables potentially affect outcomes. Fractures in this young age group are frequently high shear angle (vertical) Pauwels type 3 fractures, and benefit from fixed angle fixation. The author prefers anatomic reduction and stabilization with a sliding hip screw and a superiorly placed derotation screw. Careful attention to detail is important to obtain an anatomic reduction, which is the most important variable in the outcome of these challenging injuries.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 17 - 17
1 Dec 2016
Haidukewych G
Full Access

The orthopaedic surgeon is often consulted to manage pathologic fractures due to metastatic disease, even though he or she may not be an orthopaedic oncologist. A good understanding of the principles of management of metastatic disease is therefore important. The skeleton remains a common site for metastasis, and certain cancers have a predilection for bone, namely, tumors of the breast, prostate, lung, thyroid, and kidney. Myeloma and lymphoma also often involve bone. The proximal femur and pelvis are most commonly affected, so we will focus on those anatomic sites. The patient may present with pain and impending fracture, or with actual fracture. Careful preoperative medical optimization is recommended. If the lesion is solitary, or the primary is unknown, the diagnosis must be made by a full workup and biopsy before definitive treatment is planned. For patients with known metastasis (the most common situation), the options for treatment of pathologic lesions of the proximal femur generally center on internal fixation versus prosthetic replacement. Patients with breast or prostate metastasis can live for several years after pathologic fracture, so constructs must be relatively durable. If fixation is chosen, it must be stable enough to allow full weight bearing, since the overwhelming majority of pathologic fractures will never heal. In general, long constructs are chosen to protect the entire length of the bone. Nails should protect the femoral neck as well, so cephalomedullary devices are typically chosen. Megaprostheses can be useful in situations where bony destruction precludes stable internal fixation. Postoperative radiation is recommended after wound healing. Acetabular involvement typically requires reinforcement rings or cement augmentation with the Harrington technique. Careful multi-disciplinary medical management is recommended to minimise complications.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 67 - 67
1 Dec 2016
Haidukewych G
Full Access

Peri-prosthetic fractures above a TKA are becoming increasingly more common, and typically occur at the junction of the anterior flange of the femoral component and the osteopenic metaphyseal distal femur. In the vast majority of cases the TKA is well fixed and has been functioning well prior to fracture. For loose components, revision is typically indicated. Often, distal femoral mega prostheses are required to deal with metaphyseal bone loss. Good results have been reported in small series, however, complications, including infection remain concerning, and these implants are incredibly expensive. Although performing a mega prosthesis in the setting of a well fixed TKA is not unreasonable due to immediate full weight bearing, in my opinion, prosthetic replacement should be limited to cases of failed ORIF (rare), or in cases where fixation is likely to fail (i.e., severe osteolysis distally). For the majority of fractures above well fixed components, internal fixation is preferred for the main reason that the overwhelming majority of these fractures will heal. Fixation options include retrograde nailing or lateral locked plating. Nails are typically considered in arthroplasties that allow intercondylar access (“open box PS” or CR implants) and have sufficient length of the distal fragment to allow multiple locking screws to be used. This situation is rare, as most distal fragments are quite short. If a nail is chosen, use of a long nail is preferred, since it allows the additional fixation and alignment that diaphyseal fill affords. Short nails should be discouraged since they can “toggle” in the meta-diaphysis and do not engage the diaphysis to improve coronal alignment. Plates can be used with any implant type and any length of distal fragment. The challenge with either fixation strategy is obtaining stable fixation of the distal fragment while maintaining length, alignment, and rotation. Fixation opportunities in the distal fragment can be limited due to obstacles caused by femoral component lugs, boxes, stems, cement mantles, and areas of stress shielding or osteolysis. Modern lateral locked plates can be inserted in a biologically friendly submuscular extra-periosteal fashion. More recent developments with polyaxial locked screws (that allow angulation prior to end-point locking) may offer even more versatility when distal fragment fixation is challenging. The goal of fixation is to obtain as many long locked screws in the distal fragment as possible. High union rates have been reported with modern locked plating techniques, however, biplanar fluoroscopic vigilance is required to prevent malalignments, typically valgus, distraction, and distal fragment hyperextension.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 25 - 25
1 Dec 2016
Haidukewych G
Full Access

Few will disagree that the best femoral head that a young patient can have is his or her own, native femoral head. In the active, healthy patient under age 60 with a displaced femoral neck fracture, well-done, timely ORIF presents the best chance of preserving the patient's native femoral head. Arthroplasty is generally reserved for older patients, over age 60, where attempts at ORIF in this setting have demonstrated failure rates over 40%. Recent studies have documented that approximately 80% of young patients with displaced femoral neck fractures treated with ORIF will keep their own femoral head for 10 years after injury. The variables under the surgeon's control include timing of fixation, quality of reduction, accurate implant placement and implant selection, and capsulotomy. All of these variables potentially affect outcomes. Fractures in this young age group are frequently high shear angle (vertical) Pauwels type 3 fractures, and benefit from fixed angle fixation. The author prefers anatomic reduction and stabilization with a sliding hip screw and a superiorly placed derotation screw. Careful attention to detail is important to obtain an anatomic reduction, which is the most important variable in the outcome of these challenging injuries.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 86 - 86
1 Nov 2016
Haidukewych G
Full Access

Few will disagree that the best femoral head that a young patient can have is his or her own, native femoral head. In the active, healthy patient under age 60 with a displaced femoral neck fracture, well-done, timely ORIF presents the best chance of preserving the patient's native femoral head. Arthroplasty is generally reserved for older patients, over age 60, where attempts at ORIF in this setting have demonstrated failure rates over 40%. “Physiologic age” is a somewhat nebulous term that takes into account the health and ambulatory status of the patient. For example, a 52-year-old with end stage renal failure, severe osteoporosis, and a displaced femoral neck fracture may best be treated with arthroplasty. However, in reality, such situations are quite rare. Recent studies have documented that approximately 80% of young patients with displaced femoral neck fractures treated with ORIF will keep their own femoral head for 10 years after injury. The variables under the surgeon's control include timing of fixation, quality of reduction, accurate implant placement and implant selection, and capsulotomy. All of these variables potentially affect outcomes. Fractures in this young age group are frequently high shear angle (vertical) Pauwels type 3 fractures, and benefit from fixed angle fixation. The author prefers anatomic reduction and stabilization with a sliding hip screw and a superiorly placed derotation screw. Careful attention to detail is important to obtain an anatomic reduction, which is the most important variable in the outcome of these challenging injuries.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 67 - 67
1 Nov 2016
Haidukewych G
Full Access

Peri-prosthetic fractures above a total knee arthroplasty (TKA) are becoming increasingly more common, and typically occur at the junction of the anterior flange of the femoral component and the osteopenic metaphyseal distal femur. In the vast majority of cases the TKA is well-fixed and has been functioning well prior to fracture. For loose components, revision is typically indicated. Typically a megaprosthesis is required. For well-fixed components, internal fixation is preferred. Fixation options include retrograde nailing or lateral plating. Nails are typically considered in arthroplasties that allow intercondylar access (“open box PS” or CR implants) and have sufficient length of the distal fragment to allow multiple locking screws to be used. This situation is rare, as most distal fragments are quite short. If a nail is chosen, use of a long nail is preferred, since it allows the additional fixation and alignment that diaphyseal fill affords. Short nails should be discouraged since they can “toggle” in the meta-diaphysis and do not engage the diaphysis to improve coronal alignment. Plates can be used with any implant type and any length of distal fragment. The challenge with either fixation strategy is obtaining stable fixation of the distal fragment while maintaining length, alignment, and rotation. Fixation opportunities in the distal fragment can be limited due to obstacles caused by femoral component lugs, boxes, stems, cement mantles, and areas of stress shielding or osteolysis. Modern lateral locked plates can be inserted in a biologically friendly submuscular extra-periosteal fashion. More recent developments with polyaxial locked screws (that allow angulation prior to end-point locking) may offer even more versatility when distal fragment fixation is challenging. The goal of fixation is to obtain as many long locked screws in the distal fragment as possible. High union rates have been reported with modern locked plating techniques, however, biplanar fluoroscopic vigilance is required to prevent malalignments, typically valgus, distraction, and distal fragment hyperextension.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 65 - 65
1 Nov 2015
Haidukewych G
Full Access

Stiffness remains one of the most common, and challenging post-operative complications after TKA. The exact definition of stiffness varies, and patient expectations of post-operative motion vary as well. Pre-operative motion and diagnosis (such as post-traumatic arthritis) can influence post-operative motion, and careful patient counseling about expectations is important. Post-operative stiffness should be evaluated by ruling out infection, evaluating rehabilitation efforts, and careful physical and radiographic examination. Manipulation under anesthesia (MUA) in selected cases can be helpful. The author generally prefers to perform MUA between the 6- and 8-week mark post-operatively. Careful technique is required to minimised the risk of fracture or soft tissue injury. For more chronic stiffness, revision may be indicated, especially if an etiology is identified pre-operatively (for example, an excessively thick patellar resurfacing, an oversized femoral component, gross malrotation, etc.). CT scanning can be helpful for pre-operative evaluation and planning. During revision, thorough synovectomy and release of contractures and ligamentous balancing is performed as required. Careful attention to gap balancing, component rotation, and sizing is critical. Patients should be counseled that the results of revision for stiffness are mixed and somewhat unpredictable unless a clear etiology was found intra-operatively (for example, a grossly oversized femoral component). More frequent post-operative office visits may be helpful to guide rehabilitation progress in these challenging cases.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 102 - 102
1 Nov 2015
Haidukewych G
Full Access

The femoral diaphysis presents the best opportunity for fixation during revision THA. Both fully coated cylindrical and modular fluted tapered titanium stems have demonstrated excellent results. Cylindrical stems have demonstrated concerning rates of failure when used in larger, osteopenic canals or in canals with post-isthmal divergent morphologies. Modular stems offer the advantage of separating distal fixation needs from proximal version, leg length, and offset needs via a modular junction. Although early designs demonstrated some breakages at the taper or through thin proximal bodies, newer generation implants have not demonstrated such mechanical concerns. Additionally, the modular junctions do not appear to be having any problems with corrosion. Mid- to long-term data with various designs now support the safety and efficacy of these constructs that can handle a wide variety of challenges during femoral revision. Careful attention to detail is necessary to minimise the risk of subsidence and intra-operative fracture or femoral perforation.