Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 86 - 86
7 Aug 2023
Nanjundaiah R Guro R Chandratreya A Kotwal R
Full Access

Abstract

Aims

We studied the outcomes following arthroscopic primary repair of bucket handle meniscus tears to determine the incidence of re-tears and the functional outcomes of these patients.

Methodology

Prospective cohort study. Over a 4-year period (2016 to 2020), 35 adult patients presented with a bucket handle tear of the meniscus. Arthroscopic meniscal repair was performed using either the all inside technique or a combination of all-inside and inside-out techniques. 15 patients also underwent simultaneous arthroscopic anterior cruciate ligament reconstruction. Functional knee scores were assessed using IKDC and Lysholm scores.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 8 - 8
1 Jul 2022
Dalal S Guro R Kotwal R Chandratreya A
Full Access

Abstract

Methodology

Prospective single-surgeon case-series evaluating patients undergoing surgery by this technique. 76 cases (mean age of 33.2 years) who had primary ACL reconstruction with BTB or quadriceps tendon with bone block, were divided into 2 matched groups (age, sex and type of graft) of 38 each based on the method of femoral fixation used (interference screw or adjustable cortical suspension). Patients were followed up clinically and using PROMS from NLR with EQ-5D, KOOS, IKDC and Tegner scores. Complications and return to theatre were noted. Paired two-tailed student t-tests and Chi-square tests were employed for statistical analysis.

Results

At a mean follow-up of 82 months, peri-operative mean EQ-5D VAS, EQ-5D Index, KOOS, IKDC and Tegner activity scores showed significant improvement (p<0.05), but no significant difference between the two groups (p>0.05). Mean graft length and diameter was 77mm and 9.3 respectively. Mean interval from injury to surgery was 10.5 months. 18(23.7%) patients had associated meniscal tear with 73.3 % undergoing repair. 10 cases (13.2 %) returned to theatre including, MUA for arthrofibrosis (n=2) and intra-substance graft failure (n=2). 3 cases had to be converted to interference screw fixation due to the tightrope cutting through from the femoral bone block as a result of a technical pitfall.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 93 - 93
1 Jul 2012
Kempshall P Guro R Lewis M Mintowt-Czyz W Chandratreya A Roy W
Full Access

Aims

Wales in collaboration with the Welsh Assembly Government, has attempted to start a national ligament register.

Introduction

Norway is the lead in Europe for running a successful national quality knee ligament registry. As yet there is no UK wide registry encompassing all forms of knee ligament surgery. The issue has been discussed at previous society meetings, but no consensus has been reached.