header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 81 - 81
1 Oct 2012
Lazennec J Rousseau M Rangel A Gozalbes V Chabane S Brusson A Picard C Catonne Y
Full Access

Background

Recent literature points out the potential interest of standing and sitting X-rays for the evaluation of THA patients. The accuracy of the anterior pelvic plane measures is questionable due to the variations in the quality of lateral standing and sitting X-rays. The EOS® (EOS imaging, Paris, France) is an innovative slot-scanning radiograph system allowing the acquisition of radiograph images while the patient is in weightbearing position with less irradiation than standard imagers. This study reports the “functionnal” positions of a 150 THA cohort, including the lateral orientation of the cups.

Methods

The following parameters were measured: sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI) and anterior pelvic plane (APP) sagittal inclination (ASI), frontal inclination (AFI) and planar anteversion (ANT). Irradiation doses were calculated in standing and sitting acquisitions. Variations of sagittal orientation of the cup were measured on lateral standing and sitting images. Descriptive and multivariate analysis were performed for the different parameters studied.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 127 - 127
1 Jun 2012
Lazennec JY Boyer P Ducat A Rangel A Gozalbes V Catonne Y
Full Access

Introduction

The ceramic-on-ceramic strategy in acetabular revision faces potential limitations due to the femoral stem, as the implantation of ceramic ball head on a previously used taper is not recommended. Delta (r) ball heads with titanium sleeves have been proposed to avoid femoral revision. The study reports a minimum 3 years follow-up experience using this strategy.

Materials and Methods

This series report 42 revisions (16 metal-on-metal and 26 PE THA) in 39 patients (mean age 59.2 years, mean BMI 25). The 12-14, 5°46 sleeves were used in 24 cases and 10-12, 6° in 18 cases. (32mm ball head in 26 cases and 36 mm in 16 cases). Titanium serum level has been studied to detect the potential release from the sleeve-taper interface.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 126 - 126
1 Jun 2012
Lazennec JY Ducat A Rangel A Gozalbes V Catonne Y
Full Access

Introduction

Wear performances and fracture toughness of the alumina-matrix composite (AMC) Biolox-delta(r) are pointed out in the literature. This study is a prospective monocentric evaluation of 32 and 36 mm AMC/AMC bearing surfaces.

Material and methods

141 THA were included prospectively since 2006 in 127 patients. (62 females, 65 males, mean age 62, 2 years, mean BMI 25, 5). 134 cases were primary implantations. Mean follow-up is 40.9 months (29.8-53.4). In all patients we used the same cementless stem and cup.

Clinical and radiological data were evaluated with a special attention for ceramic fracture and squeaking.