To compare the structural durability of hydroxyapatite-tricalcium
phosphate (HATCP) to autologous iliac crest bone graft in calcaneal
lengthening osteotomy (CLO) for pes planovalgus in childhood. We present the interim results of ten patients (HATCP, n = 6
and autograft, n = 5) with a mean age of 11.5 years (8.2 to 14.2)
from a randomised controlled non-inferiority trial with six months
follow-up. The primary outcome was the stability of the osteotomy
as measured by radiostereometric analysis. A non-inferiority margin
of ≤ 2 mm osteotomy compression was set.Aims
Patients and Methods
We present the validation of a translation into
Danish of the Oxford ankle foot questionnaire (OxAFQ). We followed the
Isis Pros guidelines for translation and pilot-tested the questionnaire
on ten children and their parents. Following modifications we tested
the validity of the final questionnaire on 82 children (36 boys
and 45 girls) with a mean age of 11.7 years (5.5 to 16.0) and their
parents. We tested the reliability (repeatability (test–retest),
child–parent agreement, internal consistency), feasibility (response
rate, time to completion, floor and ceiling effects) and construct
validity. The generic child health questionnaire was used for comparison.
We found good internal consistency for the physical and the school
and play domains, but lower internal consistency for the emotional domain.
Overall, good repeatability was found within children and parents
as well as agreement between children and parents. The OxAFQ was
fast and easy to complete, but we observed a tendency towards ceiling
effects in the school and play and emotional domains. To our knowledge
this is the first independent validation of the OxAFQ in any language.
We found it valid and feasible for use in the clinic to assess the
impact on children’s lives of foot and/or ankle disorders. It is
a valuable research tool. Cite this article:
Permanent growth arrest of the longer bone is
an option in the treatment of minor leg-length discrepancies. The
use of a tension band plating technique to produce a temporary epiphysiodesis
is appealing as it avoids the need for accurate timing of the procedure
in relation to remaining growth. We performed an animal study to
establish if control of growth in a long bone is possible with tension
band plating. Animals (pigs) were randomised to temporary epiphysiodesis
on either the right or left tibia. Implants were removed after ten
weeks. Both tibiae were examined using MRI at baseline, and after
ten and 15 weeks. The median interphyseal distance was significantly shorter
on the treated tibiae after both ten weeks (p = 0.04) and 15 weeks
(p = 0.04). On T1-weighted images the metaphyseal water
content was significantly reduced after ten weeks on the treated
side (p = 0.04) but returned to values comparable with the untreated
side at 15 weeks (p = 0.14). Return of growth was observed in all
animals after removal of implants. Temporary epiphysiodesis can be obtained using tension band plating.
The technique is not yet in common clinical practice but might avoid
the need for the accurate timing of epiphysiodesis. Cite this article:
The current literature indicates that hip arthroscopy is safe in both adolescents and adults with good early outcomes but there are no available studies that directly compare the outcomes of this procedure for mixed indications between these two groups. This was a prospective cohort study of 102 consecutive supine hip arthroscopies in 96 patients (48 adolescent (<18) hips, mean age 13.9 years and 54 adult (>18 hips), mean age 33.8 years) at a tertiary referral paediatric and adult university hospital followed-up for a minimum of two years. Patient demographics, indications for surgery, Modified Harris Hip (MHHS) and Non-Arthritic Hip (NAHS) scores, operative interventions and complications were recorded.Aim
Method
An increasing number of hip prostheses are inserted without bone cement. Experimental research has shown that hydroxyapatite (HA) coated implants are strongly fixated in the bone, which is believed to reduce the likelihood of prosthetic loosening. However, in recent years, there has been much debate about the role of HA particles in third-body polyethylene (PE) wear and formerly we have shown the revision rate to be high among older-design HA coated cups. We hypothesized increased PE wear-rate using HA coated acetabular components in comparison with non-HA coated components (control group).Background
Purpose