The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth. Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry. Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h.Aim
Method
Rifampicin plays an important role in the treatment of staphylococcal prosthetic joint infection, as rifampicin-containing combinations have shown a high efficacy against Four rifampicin-resistant MRSA strains were used in this study. The MIC for all tested antibiotics was determined by Etest. Biofilms were formed on porous glass beads for 24h and exposed to Sb1 (107 PFU/mL) for 24h followed by exposure to antibiotic for 24h. Viability of bacteria after antimicrobial treatment was detected by beads sonication and plating of the sonication fluids. The minimum biofilm eradication concentration (MBEC) was defined as the lowest concentration of antibiotic required to kill all cells resulting in the appearance of no colony after plating of the sonication fluid (detection limit <20 CFU/mL). The synergistic effects were observed when Sb1 combined with antibiotics used at least 2 log-reduction lower concentrations.Aim
Method
Ciprofloxacin is recommended as anti-biofilm therapy for gram-negative periprosthetic joint infection. With ciprofloxacin monotherapy, resistance in gram-negative bacteria was observed. Therefore, we evaluated
Aim
Method